Shanghai Tongce Testing Technology Co., Ltd.VIP

从事检测技术、信息技术、建设工程技术领域内的技术开发、技术转让、技术咨询、技术服务,建设工程检测,从事房屋质量的技术检测,工程测量勘察。
Enter Shop

Yichun Deteriorated Building Assessment and Inspection Pricing

平台认证
  • Unit Price

    $22.00/square meters

  • Brand

    Concrete testing

  • MOQ

    1000square meters

Contact
Leave Msg

Platform Service

Supplier Verified



上海砼测检测技术有限公司

VIP   数字营销第4年
资料通过中商114认证
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Concrete testing

  • Unit Price:

    $22.00 / square meters

  • MOQ:

    MOQ1000square meters

  • Total:

    9999square meters

  • Address:

    Shanghai

  • Delivery:

    3days

  • View More

Description

Hazardous Building Assessment Criteria

If your home is around 30 years old, it's important to carefully determine whether it's a dilapidated building. Some houses may not be very old, but due to various reasons, they are no longer suitable for habitation. Such houses can also be considered dilapidated. So, how do we determine if a building is dilapidated? Today, our editor will discuss the methods for identifying dilapidated buildings, ensuring we all have a safe and cozy home.

I. Basic Standards. The independent column foundation is measured by the individual basic unit of a single column; the strip foundation is measured by the single face length of a natural room; the full room foundation is measured by the area of a single natural room.

1. Walls are measured by one course high and one natural room side.

2. Columns are measured by height in one layer, with each column as a unit.

3. Beams, joists, rafters, etc., are priced by span and piece.

4. Prefabricated panels are measured by pieces, cast panels by the area of a natural room.

5. Trusses are sold per piece.

Section II: Foundation, Basic Standards.

1. If the foundation is to slip, or if the bearing level is not reached due to other reasons causing uneven settlement, it may result in significant distortion, displacement, cracking, or tilting of the structure, with an ongoing deterioration trend.

2. Ground foundation loads increase due to adjacent buildings, or due to the addition of floors within the structure itself, as well as other human factors causing settlement. This then leads to significant distortion, displacement, cracking, tilting, and other conditions in the house structure, with a tendency for further deterioration.

3. Basic conditions such as aging, corrosion, and breakage have caused significant distortion, displacement, cracks, and warping in the house structure, and there is a tendency for further deterioration.

Other standards for unsafe building assessment

Section 1: Wall Column Specifications.

1. Cracks in the wall columns or the protective layer peeling off. The primary issue is exposed rebar, or the presence of significant horizontal cracks, crush, etc.

2. Significant interlaced cracks appear at the center of the wall, or accompanied by the shedding of the protective layer.

3. Columns and walls are warped, with the degree of warp exceeding 1/100 of their height.

4. Columns and walls exhibit concrete spalling, carbonation, and bulging, with the damaged area exceeding 1/3 of the total surface area. Additionally, the main reinforcement is exposed, severely corroded, and the cross-section has been reduced.

Section 2: Beam Specifications.

1. Single girder or the central part of a continuous girder may exhibit transverse cracking, either extending upwards to more than 3/2 of the girder's height with the protective layer falling off, accompanied by vertical cracks below.

2. Significant diagonal cracks appear at the ends of simply supported beams and continuous beams, and significant vertical or diagonal cracks appear at the root of the cantilever beam.

3. The frame beam exhibits significant vertical or diagonal cracks at the fixed end, or interlaced cracks appear.

4. Significant vertical cracks have appeared beneath the prefabricated panels.

5. Cracks appear around the edges on the tamping plate or interlaced cracks below.

6. Various beams and plates exhibit deflection exceeding 1/150 of their span, and cracks in the tension zone are wider than 1mm.

7. Various board protective layers have fallen off, with over half of the main reinforcement exposed, severely corroded, and cross-sectional reduction.

8. Vertical through cracks appear in prestressed prefabricated slabs; or the concrete at the ends is loose, exposing steel reinforcement, with a length exceeding 100% of the main reinforcement.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $22.00 / square meters
Sales None
Delivery Shanghai3dayswithin
Stock 9999square metersMOQ1000square meters
Brand Concrete testing
Service Area Yichun
Report Time As per the terms of the contract
Industry Type Deteriorated Building Assessment
Expiry Long Valid
Update 2023-02-03 09:20
Gallery

Shanghai Tongce Testing Technology Co., Ltd.Published byYichun Deteriorated Building Assessment and Inspection PricingGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top