Shanghai Tongce Testing Technology Co., Ltd.VIP

从事检测技术、信息技术、建设工程技术领域内的技术开发、技术转让、技术咨询、技术服务,建设工程检测,从事房屋质量的技术检测,工程测量勘察。
Enter Shop

Kunshan steel structure factory inspection cost

平台认证
  • Unit Price

    $22.00/square meters

  • Brand

    Concrete testing

  • MOQ

    1000square meters

Contact
Leave Msg

Platform Service

Supplier Verified



上海砼测检测技术有限公司

VIP   数字营销第4年
资料通过中商114认证
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Concrete testing

  • Unit Price:

    $22.00 / square meters

  • MOQ:

    MOQ1000square meters

  • Total:

    9999square meters

  • Address:

    Shanghai

  • Delivery:

    3days

  • View More

Description

Materials commonly used in most factory buildings are steel. To ensure the safety of these steel structures, it is necessary to inspect the steel, making structural safety inspection and certification indispensable. So, what aspects need to be checked during the inspection and certification of these factories?

1. Gather basic information on the steel structure factory building, such as the building's usage, structural layout, construction date, number of floors, and various blueprints.

2. Verify the steel frame layout, prefabricated component specifications, and floor heights based on the factory engineering drawings collected in Step 1. For factories without relevant engineering drawings, measure on-site and draw the necessary plans immediately.

3. Document the current status of steel pre-fabricated components in steel structural workshops, such as rust, damage at connection points, coating loss, welding defects in the appearance, and the tightness of connections, and conduct inspections and evaluations one by one.

4. Extract a certain number of prefabricated steel structural components, and select ultrasonic or magnetic particle inspection according to relevant specifications and standards for welding detection. Assess whether defects such as weld beads, arc pit cracks, and arc burn-through are present.

5. Utilize total stations to measure the deflection values of steel trusses, truss structures, and components, determining if their degree of deformation falls within the specified range.

6. The compressive strength of stainless steel sheets determines the safety of steel structural components, hence surface strength testing methods must be employed.

7. Steel structure factory buildings, their prefabricated components' corrosion resistance and safety coatings are affected by the environment, thus it is necessary to inspect the thickness of the corrosion or fire safety coatings on steel prefabricated components.

8. Based on the inspection data obtained from the structural steel components as above, conduct a series of calculations on the upper structural bearing capacity of the steel structure factory building according to relevant architectural design standards. Determine if the current-stage bearing capacity of the steel structure factory building complies with national standards and the safety application regulations for the mid to long term.

9. In accordance with relevant specification standards, assess the safety level of the current steel structure factory buildings, and propose effective solutions for prefabricated components that do not meet safety application regulations and have experienced structural damage in the current phase.

Certification Basis and Content for Steel Structure Factory Inspection

"Standard for Reliability Assessment of Industrial Buildings (GB 50144-2019)"

"Standard for Assessment of Residential Property Condition and Damage Level"

"Standard for Evaluation of Hazardous Buildings (JGJ 125-2016)"

"Code for Deformation Measurement of Buildings (JGJ 8-2016)"

5. "Standard for Building Structure Inspection Technology (GB/T 50344-2019)"

6. "Code for Design of Concrete Structures (GB 50010-2010 2015 Edition)"

7. "Code for Design of Building Structures - Load Regulations (GB 50009-2012)"

8. "Technical Code for Reinforcement Detection in Concrete (JGJ/T 152-2008)"

9. "Technical Code for Testing Concrete Strength by Core Sampling Method" (JGJ/T 384-2016)

10. "Seismic Evaluation Criteria for Buildings" (GB 50023-2009)

11. "Code for Reinforced Concrete Structure Reinforcement Design (GB 50367-2013)"

12. Specification for Steel Structure Design (GB 50017-2017)

13. Other technical standards, specifications, and procedures required by national regulations such as "Statistical Treatment and Interpretation of Outliers in Normal Samples" (GB/T 4883-2008).

14. Original architectural design documents, reinforcement construction materials, renovation construction designs, on-site inspections, and test results, etc.

Structural steel workshop inspection and appraisal of certification conclusions

Based on the "Safety Assessment Standard for Dangerous Buildings," "Reliability Assessment Standard for Civil Buildings," and other regulations and standards, conduct a comprehensive assessment of the house's safety. Prepare the appraisal report in accordance with the principles of objectivity, science, and fairness, presenting the appraisal conclusions, as well as preliminary measures and methods for handling.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $22.00 / square meters
Sales None
Delivery Shanghai3dayswithin
Stock 9999square metersMOQ1000square meters
Brand Concrete testing
Service Area Kunshan
Report Time As per the terms of the contract
Industry Type Structural Steel Factory Inspection
Expiry Long Valid
Update 2023-02-21 13:48
Gallery

Shanghai Tongce Testing Technology Co., Ltd.Published byKunshan steel structure factory inspection costGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top