Shanghai Tongce Testing Technology Co., Ltd.VIP

从事检测技术、信息技术、建设工程技术领域内的技术开发、技术转让、技术咨询、技术服务,建设工程检测,从事房屋质量的技术检测,工程测量勘察。
Enter Shop

How much is the price per square meter for the facade safety inspection of Suzhou buildings?

平台认证
  • Unit Price

    $22.00/square meters

  • Brand

    Concrete testing

  • MOQ

    1000square meters

Contact
Leave Msg

Platform Service

Supplier Verified



上海砼测检测技术有限公司

VIP   数字营销第4年
资料通过中商114认证
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Concrete testing

  • Unit Price:

    $22.00 / square meters

  • MOQ:

    MOQ1000square meters

  • Total:

    999999square meters

  • Address:

    Shanghai

  • Delivery:

    3days

  • View More

Description

"Glass Façade Engineering Technical Specification"JGJ102-96Chapter12.2.2Article: "Following the completion and acceptance of the glass curtain wall"1Yearly maintenance for curtain walls1Next inspection, thereafter every5Annual inspection1Six months after the completion of the cable facade, prestress inspections should be conducted, and subsequent inspections should be carried out at regular intervals.3Perform an annual check and adjustment; curtain wall engineering10Post New Year, conduct random sampling inspections of adhesive performance for structural adhesives at different parts, and thereafter, at regular intervals.3"Perform an annual inspection." Code for Technical Specifications on the Construction Technology of Metal and Stone Facade SystemsJGJ133-2001Chapter9.0.3Section X states: "During normal operation, the entity using the curtain wall shall inspect it at regular intervals."5Perform an annual inspection. Check materials such as boards, sealing strips, sealant, and silicone structural sealant."

Original Construction Ministry Notice on Printing and Issuing the "Management Measures for Safety Maintenance of Existing Building Facades"2006291Section 15 stipulates: "When a building facade exhibits any of the following conditions, the person responsible for safety maintenance shall proactively commission a safety assessment: (1) abnormal deformation, detachment, or explosion of panels, connecting components, or local walls; (2) damage caused by natural disasters or sudden accidents such as typhoons, earthquakes, lightning strikes, fires, or explosions; (3) potential safety hazards detected in the main structure of the related building. It is原则上recommended to conduct a safety assessment every ten years after the facade project is handed over for use following the completion and acceptance inspection."

2015The Ministry of Housing and Urban-Rural Development and the General Administration of Safety Supervision have issued the "Notice on Further Strengthening the Safety Protection of Glass curtain walls" (Building Standard [201538Section 3, Article (III) stipulates: "Strengthen the maintenance and inspection of glass curtain walls. Conduct final acceptance inspection of glass curtain walls."1After the New Year, construction units should inspect the safety of curtain walls. The person responsible for safety maintenance shall conduct special inspections of existing glass curtain walls as required by regulations. After natural disasters such as hail, typhoons, lightning strikes, earthquakes, or in the event of emergencies like fires or explosions, the person responsible for safety maintenance or a technically qualified unit they委托 shall promptly inspect glass curtain walls on buildings that may have been damaged, and carry out timely repairs for any potential safety hazards. (3) Timely assessment of the safety performance of glass curtain walls. When glass curtain walls reach their designed service life, the person responsible for safety maintenance shall entrust a technically qualified unit to assess the safety performance of the glass curtain walls. If renovations, reinforcement, or dismantling are required, a technically qualified unit shall be entrusted to implement these measures. (4) Strictly regulate maintenance and reinforcement activities of glass curtain walls. Structural repairs and reinforcement of glass curtain walls must not alter the structural components arbitrarily. Structural calculations and reinforcement plans must comply with national standards and specifications; for those exceeding technical standards, safety technical arguments should be conducted. Upon completion of structural repair and reinforcement projects for glass curtain walls, the owner, the safety maintenance responsible unit, or the unit responsible for daily maintenance management shall organize an acceptance inspection.

Pursuant to the aforementioned regulations, the construction curtain wall project shall be delivered for use after the completion and acceptance inspection., Buildings with any of the following conditions should undergo safety performance testing and assessment:

1Lacking corresponding curtain wall specifications or standards during design and construction.

2Not designed, constructed, or inspected in accordance with the regulations and standards of the same period.

3.Customers with doubts about the safety of curtain wall due to incomplete technical documents and warranty materials.

4.Abnormal deformation, displacement, detachment, or cracking of panel, support structure, connecting parts, or local wall panels; or safety accidents have occurred.

5.Damaged due to natural disasters such as typhoons, earthquakes, lightning, fires, explosions, or other unforeseen accidents exceeding the design load capacity.

6.Continued use beyond the designed service life or neglect of regular maintenance;

7Structures with major building components that have been inspected and found to have safety hazards.

8Facades requiring major repairs or renovation.

9. Upon completion and handover for use, safety inspections and appraisals are to be conducted on a principle basis every ten years.

 


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $22.00 / square meters
Sales None
Delivery Shanghai3dayswithin
Stock 999999square metersMOQ1000square meters
Brand Concrete testing
Service Area Suzhou
Report Time As per the terms of the contract
Industry Type Facade Inspection
Expiry Long Valid
Update 2023-03-17 17:21
Gallery

Shanghai Tongce Testing Technology Co., Ltd.Published byHow much is the price per square meter for the facade safety inspection of Suzhou buildings?Gallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top