AK3100/3300 Series

Power Range:
Three-input and one-output online power frequency transformer
AK3100:8KVA~30KVA
Three-in-three-out online power frequency transformer
AK3300:10KVA~400KVA
Work Method:Power-frequency dual conversion pure online type
Application Scope:
Data Storage Centers, Network Equipment, IDC Data Centers
▲ Communication Center, Network Server
Transmitter station, control room, equipment
Industrial Automatic Equipment, SMT Soldering Machine Equipment
Performance Features:
▲ Dual-transform pure online design;
▲The UPS main input power and bypass power can be separated, allowing the UPS to have dual power input. This enables the connection of two different utility power sources to the UPS separately, thereby enhancing the reliability of the output power supply.
▲ The UPS utilizes an output isolation transformer power supply method internally.
▲ Utilizes a three-phase intelligent battery management system (ABM) that automatically adjusts charging and discharging curves for different battery types and capacities. Moreover, the UPS can operate normally without connecting to the battery, facilitating battery maintenance.
▲ Dependable foolproof control switches; the input/output and maintenance bypass switches of the UPS all feature interlocked signal detection. The UPS will automatically switch to its operational state with the user's random opening and closing of various control switches, preventing abnormal power supply due to unordered closure of control switches by the user.
▲A controllable cooling system that automatically adjusts the fan speed based on the UPS load capacity and environmental temperature, extending the fan's lifespan and reducing the UPS noise.
▲ Equipped with a remote monitoring port that can reflect the working status of the UPS in real-time, and provides signal output terminals with relay contacts for easy connection to users' communication and alarm equipment. Additionally, the remote terminals can control the UPS operation, enabling switch-on/off and manual emergency shutdown functions.
▲ Non-fixed master-slave parallel connection, no need to set a master unit. Each UPS can automatically switch between master and slave. Up to 8 parallel units can be achieved, and parallel connection can be realized across UPSes of different power ratings, with automatic distribution based on UPS power ratings. Additionally, you can freely choose between shared battery or independent battery modes.
▲ Intelligent alarm feature (optional)
▲ Based on the 6th generation IGBT and high-speed static switch switching technology, higher reliability is achieved.
▲For precision instrument products, the product functions have been further optimized, with the addition of anti-interference purification power grid function.
AK3300 Series Technical Specifications Sheet
Model | AK3108 | AK3110 | AK3115 | AK3120 | AK31 30 | AK33 10 | AK3320 | AK3330 |
Rated CapacityVA) | 8KVA | 10KVA | 15KVA | 20KVA | 30KVA | 10KVA | 20KVA | 30KVA |
Work Method | Industrial Frequency Double Conversion Pure Online Transformer | |||||||
Input | ||||||||
Rated Voltage | 380VACOr400VAC) | |||||||
Input Voltage Range | 380VACOr400VAC)±25%Three-phase four-wire input | |||||||
Input Frequency Range | 50/60Hz±5HzAutomatic Identification | |||||||
Power Factor | ≥0.98 | |||||||
Maximum Input Current | 15A | 18A | 27A | 36A | 54A | 18A | 37A | 55A |
Output | Single-phase1 | Three-phase3+N | ||||||
Output Voltage | 220VAC(Or230VAC)±1% | 380VACOr400VAC)±1% | ||||||
Output Frequency | Automatic Tracking Input Frequency | |||||||
Frequency Stability (Battery Mode) | 50/60 Hz±0.05% | |||||||
Output Waveform | Sine wave | |||||||
Waveform Distortion Rate | ≤2%Linear Load≤3%Nonlinear load | |||||||
Power Factor | 0.8 | |||||||
Peak Factor | 3:1(max) | |||||||
Overall Efficiency | ≥97 | |||||||
Overload Capacity | Overload135%Maintain10minPost-conversion bypass, overload150%Maintain1sPost-Transfer Bypass | |||||||
Conversion Time | 0ms | |||||||
Protect | Input and output overvoltage protection, short circuit protection, | |||||||
Redundant features | String hot backup or cluster | |||||||
Battery | ||||||||
Battery Voltage | 384VDC | |||||||
Charging Time | 8~10Completed within hours90%Capacity | |||||||
Panel Display | ||||||||
LED | Indicate battery voltage, AC status, inverter, bypass.UPSAnomaly, Overload Indicator | |||||||
LCD | Display input/output voltage, frequency, battery voltage, load percentage, internal humidity | |||||||
Communication Interface | RS232Communication Interface SNMPNetwork Interface (Optional) | |||||||
Work Environment | ||||||||
Operating Temperature | 0~40℃ | |||||||
Relative Humidity | 0~95%No condensation | |||||||
Storage humidity | -40℃~55℃ | |||||||
Noise | <54dB | <60dB | ||||||
Physical Properties | ||||||||
Net WeightKg) | 190 | 200 | 220 | 240 | 269 | 223 | 260 | 336 |
Net WeightKg) | 247 | 256 | 265 | 288 | 305 | 280 | 317 | 393 |
Dimensions:W/D/H)(mm) | 555×725×1220 | |||||||
Select Options | Parallel ModuleHarmonic Filters, Input Isolation TransformerIntelligent Monitoring SoftwareSNMPAdapter | |||||||
Safety Standards | EN50091-1 EN50091-2 ClassA | |||||||
Execution Standards | YD/T 1095-2000 | |||||||
Model | AK-3340 | AK-3360 | AK-3380 | AK-33100 | AK-33120 | AK-33160 | AK-33320 | AK-33250 | AK-33300 | |||||
Rated CapacityVA) | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | 250KVA | 300KVA | |||||
Work Method | Power Frequency Double Conversion Pure Online Type | |||||||||||||
Input | ||||||||||||||
Rated Voltage | 380VACOr400VAC) | |||||||||||||
Input Voltage Range | 380VACOr400VAC)±25% | |||||||||||||
Input Frequency Range | 50/60Hz±5HzAutomatic Identification | |||||||||||||
Power Factor | ≥0.98 | |||||||||||||
Maximum Input Current | 72A | 108A | 130A | 160A | 190A | 245A | 310A | 385A | 470A | |||||
Output | Three-phase3+N | |||||||||||||
Output Voltage | 380VACOr400VAC)±1% | |||||||||||||
Output Frequency | Automatic Tracking Input Frequency | |||||||||||||
Frequency Stability (Battery Mode) | 50/60 Hz±0.05% | |||||||||||||
Output Waveform | Sine Wave | |||||||||||||
Waveform Distortion Ratio | ≤2%Linear Load≤3%Non-linear load | |||||||||||||
Power Factor | 0.8 | |||||||||||||
Peak Factor | 3:1(max) | |||||||||||||
Overload Capacity | Overload135%Maintain10minBack-to-back bypass, overload150%Maintain1sPost-conversion bypass | |||||||||||||
Conversion Time | 0ms | |||||||||||||
Battery | ||||||||||||||
Battery Voltage | 384VDC | 432VDC | 480VDC | |||||||||||
Panel Display | ||||||||||||||
LED | Indicate battery voltage, mains status, inverter, bypass.UPSAnomaly, Overload Indicator | |||||||||||||
LCD | Display input/output voltage, frequency, battery voltage, load percentage, and internal humidity | |||||||||||||
Communication Interface | RS232Communication Interface SNMPNetwork Interface (Optional) | |||||||||||||
Work Environment | ||||||||||||||
Operating Temperature | 0~40℃ | |||||||||||||
Relative Humidity | 0~95%No condensation | |||||||||||||
Storage Humidity | -40℃~55℃ | |||||||||||||
Noise | <60dB | <65dB | <70dB | |||||||||||
Physical Properties | ||||||||||||||
Net WeightKg) | 351 | 497 | 556 | 756 | 901 | 1300 | 1350 | 2200 | 2200 | |||||
Gross WeightKg) | 408 | 574 | 633 | 856 | 1001 | 1400 | 1450 | 2400 | 2450 | |||||
Dimensions (W/D/H)(mm) | 555×725×1220 | 800×745×1400 | 1070×745×1400 | 1420×745×1810 | 1630/850/19000 | |||||||||
Select Options | Parallel Module, Harmonic Filter, Input Isolation Transformer, Intelligent Monitoring SoftwareSNMPCompatible,Appliance | |||||||||||||
Safety Standards | EN50091-1 EN50091-2 ClassA | |||||||||||||
Standard of Execution | YD/T 1095-2000 | |||||||||||||