AK1100 Series

Power Range: Single Input/Single Output AK1KVA to 30KVA
Operation Mode: Pure Online Double Conversion Power Frequency
Application Fields:
Workstations, terminals, OA equipment, delivery machines, servers
▲ Equipment, Traffic Management Centers, Network Server Rooms
▲ Mining and industrial equipment, surveillance, security systems, etc.
Performance Features:
▲ Dual conversion pure online design
Wide input voltage range, extending battery life
▲ Wide input frequency range ensures stable operation for various fuel generators.
Low output waveform distortion rate, reduces harmonic interference, and improves power supply quality.
▲ Parallel-connected autonomous balanced current charger, current imbalance ≤ 3%, fully meets the system's configuration requirements to the maximum extent
▲ Cold start function, allowing direct startup of the UPS with a battery pack under no mains power, meeting the emergency needs of users. It also features strong cold start capabilities, enabling cold start operations even under full load.
▲ High input power factor reaches above 0.98, high utilization rate of municipal electricity
High load capacity and good load compatibility, suitable for various types of loads, meeting the needs of various application scenarios.
▲ The entire unit employs advanced anti-EMI (Electromagnetic Interference) technology, meets international standards, boasts excellent electromagnetic compatibility, and will not cause electromagnetic interference to the load equipment.
▲ User-friendly LCD interface, bridging the communication gap between man and machine
▲ Through the RS232 interface, the UPS intelligent monitoring software can display the UPS operating status in real-time, automatically save computer data, and securely shut down the computer.
▲ Intelligent alarm feature (optional)
▲ With an external SNMP adapter, the UPS features direct internet connectivity, providing immediate UPS data and power information. It communicates and manages through various network management platforms, instantly integrating the UPS into the network.
▲ Designed with over-voltage, over-current, battery under-voltage, rapid current limiting, and short-circuit protection functions to prevent malfunctions caused by human operation errors, ensuring reliable operation of the equipment under various conditions.
▲ Utilizing green rectification and inversion technology to provide users with clean energy
AK1100 Series Technical Specifications
1KVA~8KVA
Model | AK1101 | AK1102 | AK1103 | AK1104 | AK1106 | AK1108 |
Rated Capacity
| 1KVA | 2KVA | 3KVA | 4KVA | 6KVA | 8KVA |
Please provide the Chinese content to be translated.Numbers | Single-phaseL+N+G | |||||
Rated Voltage | 220VAC or 230VAC | |||||
Work Method | Dual conversion pure online | |||||
InputPlease provide the Chinese content you would like translated into American English. | ||||||
Input Voltage Range | 155~300VAC | |||||
Input Frequency Range | 50(60)Hz±20% | |||||
Input Power Factor(PF) | ≥0.98 | |||||
Soft Start | 0~100 % 3-5sec | |||||
Maximum Input Current | 6A | 10A | 14A | 24A | 34A | 45A |
InputOut | ||||||
Output Voltage | 220VAC±1% | |||||
Output Frequency | 50/60 Hz (Battery Mode) | |||||
Power Factor | 0.8 | |||||
Waveform Distortion | ≤2% (linear load) | |||||
BoShape | Sine Wave | |||||
Overload Capacity | OverloadMaintain 135% for 10 minutes then bypass, bypass after 1 second with 150% overload. | |||||
Peak Factor | 3:1(max) | |||||
Overall Efficiency | Dual Conversion Mode≥94% Economy Model ≥97% | |||||
Conversion Time | 0ms | |||||
Please provide the Chinese content to be translated.Protect | Input/Output Overvoltage Protection, Short Circuit Protection, Overtemperature Protection, etc. | |||||
ElectricityPond | ||||||
Battery Voltage | 48VDC/192VDC (optional) | 192VDC/240VDC (optional) | ||||
Charging Time | 8-10 hours to reach 90% capacity | |||||
Panel display | ||||||
LED | Indicate battery low voltage, AC power status, shunt, bypass.UPS anomaly, overload indication | |||||
LCD | Display input/output voltage, frequency, battery voltage, load percentage, internal temperature | |||||
Communication | ||||||
Communication Interface | RS-232 Communication Interface SNMP Network Interface (Optional) | |||||
Protective Standards | ||||||
Surge Protection | CompliantEEE527B Identification | |||||
Noise Protection | CompliantFCC/A Standard | |||||
Surge resistance | 15/800μS 5KA;10/30μS 20KA | |||||
Ingress Protection (IP) rating | IP21 | |||||
Work environment | ||||||
Temperature | 0~40℃ | |||||
Relative Humidity | 0-95% No Condensation | |||||
Cooling Method | Smart Fan Speed Controller | |||||
Storage Temperature | -40℃~55℃ | |||||
Noise | <55 dB (at 1 meter from the machine) | |||||
Physical Properties | ||||||
Net WeightKg) | 46 | 63 | 75 | 65 | 69 | 88 |
Gross WeightKg) | 56 | 78 | 90 | 85 | 89 | 118 |
Dimensions:W×D×H)mm Long Machine H Standard Machine | 200×530×460(S) | 200×600×490(S) | 220×580×540(S)
| 220×580×700 | ||
200×530×600(H) | 200×600×632(H) | 220×580×700(H) | ||||
Model | AK1110 | AK1112 | AK1115 | AK1120 | AK1125 | AK1130 | |
Rated Capacity
| 10KVA | 12KVA | 15KVA | 20KVA | 25KVA | 30KVA | |
Rated Voltage | 220VAC or 230VAC | ||||||
Work Method | Dual Conversion Pure Online | ||||||
Input Enter | |||||||
Input Voltage Range | 155~300VAC | ||||||
Input Frequency Range | 50(60)Hz±20% | ||||||
Input Power Factor | ≥0.98 | ||||||
Soft Start | 0~100 % 3-5sec | ||||||
Maximum Input Current | 56A | 65A | 84A | 112A | 134A | 168A | |
Please provide the Chinese content to be translated. Out | |||||||
Output Voltage | 220VAC±1% | ||||||
Output Frequency | 50/60HzBattery Mode | ||||||
Power Factor | 0.8 | ||||||
Waveform Distortion Rate | <2% (linear load) | ||||||
Bo~ Shape | Sine Wave | ||||||
Overload Capacity | OverloadMaintain 135% for 10 minutes then bypass, bypass after 1 second with 150% overload. | ||||||
Peak Factor | 3:1(max) | ||||||
Overall Efficiency | Dual Conversion Mode≥94% Economic Model ≥97% | ||||||
Conversion Time | 0ms | ||||||
Please provide the Chinese content to be translated. Protect | Input and output overvoltage protection, short circuit protection, overtemperature protection, etc. | ||||||
Electricity Pool | |||||||
Battery Voltage | 192VDC | 240VDC | |||||
Charging time | 8-10 hours to reach 90% capacity | ||||||
Panel Display | |||||||
LED | Indicate battery low voltage, AC power status, inverter, bypass.UPS abnormal, overload indicator | ||||||
LCD | Display input/output voltage, frequency, battery voltage, load percentage, and internal temperature. | ||||||
Communication | |||||||
Communication Interface | RS-232 Communication Interface SNMP Network Interface (Optional) | ||||||
Protection Standards | |||||||
Surge Protection | CompliantIEEE 527B specification | ||||||
Noise Protection | MeetsFCC, A Standard | ||||||
Surge Resistance | 15/800μS 5KA;10/30μS 20KA | ||||||
Protection Grade | IP21 | ||||||
Work Environment | |||||||
Temperature | 0~40℃ | ||||||
Relative Humidity | 0-95% No Condensation | ||||||
Storage Temperature | -40℃~55℃ | ||||||
Noise | <55dB (1 meter from the machine)mPlease provide the Chinese content to be translated.) | ||||||
Physical Properties | |||||||
Net WeightKg) | 100 | 120 | 150 | 220 | 230 | 245 | |
Gross WeightKg) | 130 | 140 | 175 | 250 | 260 | 275 | |
Dimensions:W×D×H)mm Long Machine, High Standard Machine | 300×590×870 | 410×670×935 | 730×460×1180 | ||||