The AKL series 4U high-frequency switching power supplies feature high performance, stability, reliability, compact size, and lightweight, and come with essential protection functions like overvoltage, current limiting, and short-circuit protection. Voltage, current, and overvoltage protection values can be pre-set before loading, and all set parameters can be easily checked during operation. The process is simple and convenient.

Product Features:
Voltage and Current Pre-Setting: The panel features pre-set buttons for pre-determining voltage and current values.
Voltage and Current Stabilization: Continuously adjustable from zero to rated value, automatic switching between voltage and current stabilization
Overvoltage Protection: The machine will automatically lock after protection and unlock automatically upon restart.
Overcurrent Protection: Rated current output overload protection, short-circuit protection (output shutdown after short-circuit, optional)
Short-circuit Protection: Allows for long-term short-circuit or short-circuit startup in any state
Short-circuit Alarm: Audible and visual power alarm when an output short-circuit occurs.
Pulse Operation: Can be configured with a timer controller to form a DC pulse power supply (optional)
Communication: Standard RS485 communication interface
Special specifications and features are customizable.

Specification parameters
Communication Input | Input:AC220VOrAC380V±10% 50Hz±10% |
Direct Current Output | Output: Voltage Approx.0-50V,Current approximates0-240A |
2Stabilized Voltage Accuracy | Source Effect≤0.5%Rated value (only due to input voltage variation)-5%~10%Output voltage change rate due to time Seasonal漂移≤0.5%Rated value (only due to the continuous operation time of the power supply being greater than)8Rate of change of output voltage due to hourly fluctuations Warm漂移≤0.1%/℃±2Individual (within 30 minutes) (exclusively due to the rate of change of output voltage caused by environmental temperature fluctuations within the power usage environment temperature range) Load Effect≤0.5%Rated Value±2Individual character (only due to the output voltage change rate when the output current changes from zero to the rated value) |
3Flow Stabilization Precision | Source Effect≤ 0.1%Rated value (only due to the change in input source voltage)-5%~10%Voltage output rate of change due to timing Seasonal漂移≤ 0.3%Rated Value (only due to continuous power-on time exceeding)8Rate of change of output voltage due to hourly fluctuations Warm漂移≤ 0.1%/℃±2Character (within half an hour) (only due to the rate of change of output voltage caused by environmental temperature changes within the power supply and usage temperature range) Load Effect≤1%Rated Value±2Character (only due to the change rate of output current when the output voltage varies from zero to the rated value) |
4Wavy patternr.m.s) | ≤0.5%+50mVOutput at the highest voltage |
5Efficiency | ≥ 90%(Measured at rated output) |
6Output Voltage Adjustment Range | Approximate0 ~50VContinuous adjustable |
7Output Current Adjustment Range | Approximate0 ~240AContinuous adjustable |
8Output Voltage and Current Display Method | LCDOr digital tube display |
10Output Voltage, Current Settings | Rotary encoders and push-button settings, with customizable touch control. |
12Protection Method | 1Short circuitOvervoltage, overcurrent, overheating protection with corresponding fault indication; 2TransformerIGBTModular rectifier diodes are cooled with heat-sink fans. |
13Work Method | Continuous operation at full load |
14Display Error | Voltage meter≤ ±0.5%±1Unit (Measurement Range)10%~100Rated Value (%) Ammeter≤ ±1%±1Unit (Measurement Range)10%~100Rated Value (%) |
15Chassis dimensions | 430*178*550(Wide)*High*Deepmm) |
16Application Environment | 1Indoor Use Only 2Temperature:-20℃~40℃ ; 3Air Humidity:≤80% |