Fully Automatic Viscosity Meter_SupplyPro Co., Ltd._Shanghai Silida Scientific Instruments Co., Ltd.
欢迎来到Shanghai Silida Scientific Instruments Co., Ltd.!
  • 销售热线:021-64925147  18701850186


Fully Automatic Viscosity Meter

价      格190000.00

最小起订1 Piece库存999 Piece

Location
Shanghai
有效期至
长期有效
最后更新
2022-07-29 16:22
View Count
27

Business Card

  • Your company's名称Shanghai Silida Scientific Instruments Co., Ltd.
  • 联 系 人姚经理 (先生)
  • Your company'sPhone021-64925147
  • Mobile号码18701850186
  • Company Address88 Chengjian Road, Meilong Town, Minhang District, Shanghai

买家正在看

  • Automatic Viscosity Meter

    190000.00

  • Automatic Viscosity Meter

    Negotiable

  • Fully Automatic Viscosity Meter

    190000.00

  • Fully Automatic Viscosity Meter

    190000.00

Product Details
Brand:
Array
Shipment Origin:
Shanghai

Ncy-xSeries (2-digit, 4-digit, 6-digit)

Viscosity Automatic Measurement System

Manual

(NCY-X, 2018.3 Edition)

Over three decades of experience in research, manufacturing, and service for 0.01℃ precision temperature-controlled baths.

Over two decades of experience in research, manufacturing, and service for NCY Automatic Viscosity Meters

Self-owned intellectual property; mechanical and electronic, hardware and software

All自主研发设计, no copyright entanglements!

The Viscosity Measurement System is a specially designed and developed automated testing equipment for polymer properties such as intrinsic viscosity, viscosity number, average degree of polymerization, and viscosity average molecular weight. Depending on the number of testing units configured in the system, it is divided into NCY-X/2, NCY-X/4, and NCY-X/6 models, each equipped with two, four, or six testing units respectively, allowing for simultaneous use of two, four, or six viscometers.

UtilizeNcy-xViscosity Automatic Measurement System Ahead:

The measurement of the time required for a certain amount of solution, previously manually processed, to flow through a capillary.

The original determination of data validity, which was previously done manually,

Just like the NCY Automatic Viscosity Meter, it will still be executed by the system.

The system will still display the solution flow in the capillary viscometers within each unit in real-time and visually.

The system will still automatically repeat testing and eliminate out-of-tolerance results to achieve accurate flow time.

The system still retains the research achievements from our national science and technology projects in the 1990s - the JWC precision constant-temperature water bath. It will continue to deliver temperature fluctuations and distributions better than ±0.01℃ over extended periods, ensuring consistency of test data at any moment and position.

In addition, the automatic testing system will also feature the following new functions:

Automated liquid preparation instrument with a precision of up to 0.1% concentration, capable of conveniently preparing sample solutions (one-button liquid preparation).

Double-glazed vials with isolation design, ensuring the prepared solution dissolves rapidly and evenly in a precise, constant-temperature oscillating bath, free from interference by moisture.

Automated Liquid Delivery System, eliminating the need for manual feeding of the viscosity tube. The comprehensive device automatically filters the solution and delivers it into the capillary of the viscometer.

Automatic test completed, the system will automatically extract waste liquid and wait for the arrival of the next sample to automatically complete the capillary rinsing and testing.

When cleaning capillaries is required, simply initiate the cleaning program, and the system will autonomously complete the entire process of liquid introduction, soaking, recovery, cleaning, and drying, without any manual involvement.

1. System Structure

Ncy-xThe automatic viscosity measurement system consists of the following components:

1.1 NCY Test Unit, equipped with various sensors and paired with a central controller, is capable of performing tests and cleaning the capillary viscometer within the unit, among other tasks.

1.2 JWC series precision temperature-holding baths for placement of test units, ensuring normal operating environmental temperature (instruction manual included).

1.3 PY Series Automatic Liquid Filling Machine (optional, manual included).

1.4 WR-2 Rapid Sample Dissolution Constant Temperature Oscillator (optional, manual included), equipped with double set of sample dissolution bottles, operates at precise temperatures while effectively avoiding water interference during operation.

1.5 NCY-X Viscosity Automatic Measurement System, integrated into the central control system, performs an accurate measurement of the time it takes for the solution to flow through the capillary.

Sampler

Samples are dissolved in the dissolution vials and placed here. After the system initiates testing, the required solution will be automatically filtered through a sand core and sent to the capillary.

1.7 Cleaning System

Pre-set various detergents to clean the viscometer, filter, and all fluid lines during automated testing for a specific unit within the central system. After cleaning, perform a drying process.

1.8 Commercial or industrial computers with a printer, keyboard, and monitor, etc.

1.9 NCY-X Automatic Viscosity Test System Central Controller

Comprehensive automation of the entire system.

The entire system operates seamlessly on a Chinese interface using our independently developed software (Copyright owned).

In light of our developed and produced NCY Automatic Viscosity Meter, which has held an 80%+ market share domestically for nearly two decades, our upgraded NCY-X Automatic Viscosity Measurement System is now compatible with the NCY Automatic Viscosity Meter. Use the NCY Automatic Viscosity Meter

Ncy-x 系列黏度自动测定系统(2位、4位、6位)

Ncy-x 系列黏度自动测定系统(2位、4位、6位)

As in the past three decades, we still provide our vast user base with products featuring our own

Products with intellectual property rights in design, hardware, and software, thus, we can still provide perfect after-sales service to a wide range of customers.

2. Arrangement of Automatic Viscosity Measurement System

This automated testing system is composed of several components, which can be arranged in various configurations according to the user's setup, but its fundamental principle is:

2.1 Ensure all pipeline distances are as short as possible, while also considering actual operations such as filling and emptying. The cover image illustrates a typical reasonable layout.

2.2 The pipeline connecting from the central control unit to the viscometer must start from the central control system and gradually decrease, without any rise in between.

3. Sample Processing

3.1 Automatic Solution Preparation

See the PY Automated Mixture Instrument manual (optional accessories).

3.2 Quick Dissolution of Samples

Refer to the WR-2 Rapid Sample Dissolution Oscillator manual (optional accessory), equipped with a sample bottle featuring a double-layered jacket.

The dissolution process of the sample in the solvent can sometimes be quite lengthy, taking one, even more hours, and requires oscillation at as high a temperature as possible to accelerate completion. Excessive temperature will lead to degradation, so the temperature should be precisely controlled.

4. Vacuum Pressure Adjustment

The automatic testing system operates under vacuum pressure. This system is equipped with dedicated pressure sources for the injection, testing, transfer of washing fluid, and drying. Different vacuum pressures need to be adjusted according to the sample and the solvent composition of the washing fluid.

Vacuum Pressure Adjustment Method:

Two pressure gauges are located on the control system panel: the constant pressure gauge adjusts and controls the working pressure of the sample solution, while the pump pressure gauge adjusts and controls the working pressure of the washing liquid.

Ncy-x 系列黏度自动测定系统(2位、4位、6位)

Vacuum pressure regulation methods are as follows:

Press the mode key (left button), until L appears0-2 shows the current lower limit of the vacuum setting. Press the up and down keys to change the upper limit setting.

Press the mode key again to display H1After -2, the current maximum vacuum level is displayed. Press the up and down buttons to change the set maximum value.

Note: The vacuum pressure value is negative.

5. Inlet and Testing

Prepare a clean empty solvent sample bottle, pour half of the solvent bottle containing the dissolved sample from the oscillator into the empty solvent bottle, and place them together in the corresponding sampling unit position.

During testing, only approximately 13mL of sample is required. Therefore, if it's necessary to rinse before testing, you will need to prepare about 26mL of solution at a time. Place the solution bottle on the autosampler, press the rinse button for the corresponding unit, and the solution bottle holder advances. Stop when the previous solution bottle (used for rinsing) is in the liquid tube position, then the liquid tube descends and inserts into the volumetric flask, while the flask's mouth is automatically sealed. After initiating the test, the testing system will automatically draw the solution from the solution bottle, complete the rinse, and automatically drain the liquid.

Keep pressing the test button, another sample vial is sent to the testing station, wait for the test to start. Test completed, the sample vial is returned to the starting position.

Ncy-x 系列黏度自动测定系统(2位、4位、6位)

Sample Solution Bottle Location

Wash position: The liquid suction tube is inserted into the front beaker, and the mouth of the subsequent beaker automatically covers it.

Test Port: Insert the liquid tube into the sample bottle at the back.

Test complete, reposition the solution bottle to the starting position.

After initiating the test program for this unit on the computer, the unit automatically enters the working state. The subsequent work is performed automatically by the system. The operator can view the progress of the unit's testing on the screen, and a dialog box will automatically pop up if an issue is encountered during the test.

Test completed; after the system automatically discharges the waste liquid, it proceeds to the next test phase.

Ncy-x 系列黏度自动测定系统(2位、4位、6位)

6. Capillary Viscometer Cleaning and Drying

After a period of use, the viscometer should be cleaned.

First, place a solution bottle in the rinse position (or test position) of the sampler, and the pipette will automatically insert into the bottom of the bottle (this is very important!!)

Inspect and ensure there is an adequate supply of solvents like detergents and potable water. Check and confirm that containers for waste liquids and wastewater have sufficient remaining space.

Then, you can initiate and complete the full cleaning-drying process.

Select "Detergent Soak Cleaning" on the computer interface, and the viscometer can complete the entire cleaning-drying process.

7. Routine Maintenance

7.1 Liquid Storage Bottle

The storage bottles require regular monitoring of the liquid level. For waste liquid collection, timely cleaning is necessary when the level is high; for new liquid, timely replenishment is essential.

Remove the cap with care, noting the original state. Some may come with a layer of Teflon film to address the corrosion issue. When reinserting the plastic tube, be sure to check the tube's numbering and the corresponding entry marked on the label. Tighten the cap securely when replacing it, ensuring a proper seal.

7.2 Vacuum Pump

This type of vacuum pump, when in use, if the suction inlet maintains vacuum (low pressure), it may cause the oil pump to spray oil outward from the suction inlet. The machine has been equipped with a special program in the control system to prevent oil spraying. However, after a considerable period of use, the oil level will also decrease. When the oil level in the pump side's oil gauge falls below the "min" mark, oil should be added to the vacuum pump from the suction inlet until it reaches the second marking on the oil gauge.

8. Key Technical Specifications

Time measurement range:0.01s~9999.9s;
Timing Repeat Accuracy:0.02s (excl. impact of residual impurities in the solution)
Temperature control range:(5~80)℃;
Temperature Fluctuation:Better than ±0.01℃
Temperature Distribution:Superior to ±0.01℃
Long-term stable temperature:Better than ±0.01℃
Power Supply:220V,(50~60)Hz,10A;
Rated Power:0.5 kW (see respective manuals for other thermostatic baths and refrigerators).

9. After-Sales Service

This product includes a five-year free warranty on the test unit.

Computer components, adhering to the maintenance and repair standards of the computer industry.

Other parts, two years of free warranty.

Lifetime warranty.

ViscousDuct testing is a manual craft that requires both education and technical skill; it's not an easy task these days!

Ncy-xViscousDegree Automatic Testing System, the entire process is fully automated with minimal human intervention.

ViscousFully automated experimental technology for the degree test, enabling:

The entire experimental process has achieved a further level of automation.

Significantly reduced the skill requirements for laboratory personnel.

Effectively isolate personnel from the presence of hazardous du reagents.

Further streamline experimental operation staff, effectively reduce expenditures.

Effectively reduce managers' headaches.