The GC-9860 Plus Networked Gas Chromatograph is an upgraded model based on our GC-9860, featuring a sophisticated design with a reasonable structure. It incorporates our independently developed color screen display technology and gas electronic flow control technology, significantly enhancing its automation level and overall performance. The successful development and application of the gas electronic flow control technology have narrowed the gap between domestic and imported models. Additionally, with the instrument's network remote transmission and control capabilities, it makes unattended operation, decentralized monitoring, and centralized control a reality.
Features of Network Feedback Chromatograph:
● Equipped with a 10/100M auto-negotiating Ethernet communication interface and an integrated IP protocol stack, allowing the instrument to easily transmit data over long distances via corporate internal LANs and the internet; facilitates the setup of laboratories, simplifies the configuration and management of laboratory data.
The instrument is internally designed with 3 independent connection processes, allowing connections to local processing, department heads, and senior management. This facilitates real-time monitoring of the instrument's operation and analysis of data results by department heads and senior management.
● The instrument is equipped with an integrated one-stop control chromatography instrument workstation, eliminating the traditional data processing of collection cards, supporting up to 253 chromatographs to work simultaneously, and achieving data processing and reverse control of chromatography instruments.
● The integrated control workstation features an in-built Modbus/TCP server, facilitating easy connection of analytical results to DCS (Distributed Control System) and enabling real-time feedback and control of all chromatography instrument parameters.
● The instrument employs vacuum fluorescent display technology, exuding a high-end, sophisticated appearance with user-friendly and straightforward interface operations; equipped with both Chinese and English operating languages to meet diverse user requirements.
● The instrument features a modular structural design for clear layout and easy replacement or upgrade, ensuring investment effectiveness; it can meet complex sample analysis requirements and is available with a variety of high-performance detectors, such as FID, TCD, ECD, FPD, and NPD, etc.
● We've completely eliminated the traditional mechanical valves and pointer-type pressure gauges! Now, we use EPC technology for airway control, enhancing the level of gas chromatography automation.
● True airway fault automatic protection, pressure and flow detection automatic ignition and shutdown, automatic priority shutdown, and automatic airway opening execution achieve one-touch start-up.
● The instrument is designed with a timed self-start program, allowing for easy online analysis of gas and liquid samples (sampling components required); the system is designed with an automatic sampler interface, facilitating the connection and future upgrades of automatic samplers.
Key Technical Specifications:
● Operation Display: Vacuum Fluorescent Display (Utilizing Agilent Technology)
● Temperature Control Zones: 6 Channels
● Temperature Control Range: 4℃ above room temperature to 450℃, Increment: 1℃, Accuracy: ±0.1℃
● Number of Programmed Temperature Stages: 8-16 (Optional)
● Rate of升温: 0.1~50℃/min (Standard Model); 0.1~80℃/min (High-Speed Model)
● External Events: 8 channels; Auxiliary Control Outputs: 4 channels
● Injector Types: Filling Column Injection, Capillary Injection, Six-port Valve Gas Injection, Automatic Headspace Injection Available
Detector Quantity: 3; (FID, TCD, ECD, FPD, NPD) - Selectable
● Air Path Control Method: (Optional) (1) Available with high-precision valve control for real-time digital display of pressure and flow, with PC synchronization; (2) Available with a full feedback EPC control system.
● EPC, EFC Operating Modes: 2; Constant Current Mode, Constant Voltage Mode
● EPC, EFC working gases: 5 types; nitrogen, hydrogen, air, helium, argon
● EPC, EFC Process: 4th Level
● EPC, EFC control range:
Pressure: 0~0.6 MPa; Flow rate 0~100 sccm or 0~500 sccm (air)
● EPC, EFC control accuracy: Pressure 0.01 KPa; Flow rate 0.01 sccm
Pressure Sensor: Accuracy: <±2% of full scale; Repeatability: <±0.05 KPa; Temperature Coefficient: <±0.01 KPa/°C; Range: 0~0.3MPa or 0~0.6MPa
● Flow Sensor: Accuracy: <±5% of full scale; Repeatability: <±0.5% (full scale); Range: 0~500 sccm
● Sample Starting: (Manual, Automatic, Syringe Automatic Detection) Optional
Communication Interface: Ethernet: IEEE802.3 Hydrogen Flame Ionization Detector (FID)
● Detection Limit: Mt ≤ 3×10^-12 g/s (n-hexadecane-isooctane solution)
● Baseline Noise: ≤5×10^-14A
● Baseline Drift: ≤1×10^-13A/30min
● Linear Range: ≥106
● High Operating Temperature: ≤450℃ Thermal Conductivity Detector (TCD)
● Sensitivity: S≥10000 mV.ml/mg (n-hexadecane-isooctane solution) (amplification options: 1x, 2x, 4x, 8x)
● Baseline Noise: ≤10μV
● Baseline Drift: ≤30μv/30min
● Linear Range: ≥104 Electron Capture Detector (ECD)
Detection Limit: ≤1×10^-14 g/s (hexachlorocyclohexane-isooctane solution)
● Baseline Noise: ≤0.03mV
● Baseline Drift: ≤0.2mV/30min
Linear Range: ≥104
Source: 63Ni Flame Photometric Detector (FPD)
● Detection Limit: (S) ≤ 5×10^-11 g/s; (P) ≤ 1×10^-12 g/s (Methyl Parathion in Anhydrous Ethanol Solution)
● Baseline Noise: ≤0.03mV
● Baseline Drift: ≤0.2mV/30min
● Linear Range: ≥103 (S) 102 (P) Nitrogen-Phosphorus Detector (NPD)
● Detection Limit: (N)≤1×10^-13 g/s; (P)≤5×10^-14 g/s (Azobenzene-Malathion-Isooctane Solution)
● Baseline Noise: ≤0.03mV
● Baseline Drift: ≤0.2mV/30min
● Linear Range: ≥102 (N) 103 (P)
Networked Return Control Gas Chromatograph