Automated Pyrolysis Desorption Instrument - ATDS-10A

价      格6800.00

最小起订1 piece库存0 piece

Location
Shandong Zaozhuang
有效期至
长期有效
最后更新
2022-03-24 09:23
View Count
60

Business Card

  • Your company's名称Shandong LuChuang Analytical Instruments Co., Ltd.
  • 联 系 人张文 (先生)
  • Your company'sPhone13062028296
  • Mobile号码13062028296
  • Company AddressNo. 39, Parallel North Road, Tengzhou City, Shandong (Taoyuan Garden Office Building)

买家正在看

  • LC-3000 HPLC System (Single Pump)

    6800.00

  • LC-500 Binary High-Pressure Gradient Fluid

    6800.00

  • ATDS-800 Thermal Desorption Instrument

    6800.00

  • Luna Chromatograph GC-9870 Gas Chromatograph (EO Residue Detection)

    68000.00

Product Details
Manufacturer:
Array
Origin:
Shandong
Type:
Thermal analyzer

I. Instrument Introduction

The ATDS-10A fully automatic thermodesorption instrument is a new generation model featuring full automation design, a touch screen display, and enhanced ease of operation, capable of continuously processing 10 samples. It can also be customized to include either ambient temperature or low-temperature secondary desorption components based on customer requirements.

The ATDS-10A full-automatic pyrolysis desorption instrument is compatible with all imported and domestic gas chromatographs, and meets the following standards.

"HJ/644-2013 Determination of Volatile Organic Compounds in Ambient Air - Sampling with Adsorption Tube - Thermal Desorption Gas Chromatography-Mass Spectrometry"

2. "HJ/T400-2007 Method for Sampling and Determination of Volatile Organic Compounds and Aldehydes and Ketones in Vehicle Cabin"

3. "GB/T18883-2002 Indoor Air Quality Standard"

4. "HJ/583-2010 Determination of Benzene Compounds in Ambient Air—Solid Adsorption/Thermal Desorption-Gas Chromatography"

5. "GB/50325-2010 Code for Indoor Environmental Pollution Control of Civil Engineering Construction" and others.

6. "HJ734-2014 Determination of Volatile Organic Compounds from Fixed Pollutant Sources - Solid Phase Adsorption/Gas Chromatography" and others.

II. Instrument Features and Main Functions

Can automatically run 10 samples without the need for staff supervision.

2. Power-on self-check, fault alarm and prompt, with independent technology for automatic positioning and calibration of the sample tray.

3. Microcomputer program control, featuring main functions:

(1) Method parameter settings, real-time animation display of working status, runtime;

(2) Desorption zone, sample valve, sample transfer tube, and secondary desorption zone; all four are individually heated and temperature-controlled.

(3) Set up the analysis program and press the run button for automatic completion of all sample analysis.

(4) Additional components for ambient temperature or low temperature secondary desorption can be added based on customer requirements.

(5) The GC and chromatography data processing workstation can be started simultaneously, or the device can be initiated by external programs.

4. This unit features an in-built standard sample simulation function, allowing for more convenient creation of working curves via a pyrolysis desorption instrument.

5. Features an integrated sampling tube activation program, which automatically activates sampling tubes after adsorption.

6. Automate desorption, purge吸附, re-desorption, sample injection, and reverse purge cleaning functions via time programming.

7. Utilize electronic cooling and a two-stage thermal desorption process to ensure narrow chromatographic peak shapes.

8. Sample transfer tubes and sampling valves feature an automatic backflushing function, preventing cross-contamination between different samples.

9. To enhance the convenience and accuracy of using this gas chromatograph with imported models, it is equipped with interfaces compatible with various imported instruments, ensuring easy connections.

10. Optional: Elastic quartz tubes for sample conveyance can be added for the analysis of active substances.

11. Sample needle replacement is convenient, compatible with all GC injection ports of models from both domestic and international brands.

Section 3: Main Technical Parameters of the Instrument

Desorption 1 temperature control range:

Room temperature — adjustable from 400℃ with increments of 1℃.

2. Valve inlet system temperature control range:

Room temperature — adjustable from 220°C, with increments of 1°C.

3. Sample transmission pipeline temperature control range:

Room Temperature — 240°C, adjustable at an increment of 1°C.

(The temperature control of the transmission pipeline is implemented with low-voltage power supply for operational safety.)

4. Desorption 2 Temperature Control Range:

Room temperature — 400℃ with adjustable increments of 1℃.

(Rising rate > 2000°C/min)

5. Cold Trap Temperature Control Range:

-35°C to 50°C, adjustable in increments of 1°C

(Operated with an electronic refrigeration unit, no need for liquid nitrogen cooling)

6. Temperature Control Accuracy: < ±0.1℃

7. Temperature control gradient: ±0.1℃

8. Sample Positions: 10

9. Desorption Recovery Rate: >98% (related to components)

10. Backflush cleaning flow rate: 0-600 ml/min (continuously adjustable)

11. Simulated Sampling Flow Rate: 100 ml/min

12. Instrument dimensions: 450×360×510mm³

13. Instrument Weight: Approximately 30kg.