LC-3000 HPLC System (Single Pump)_SupplyPro Co., Ltd._LC-3000 HPLC (Single Pump), Chemical Energy Network_Shandong LuChuang Analytical Instruments Co., Ltd._Zhongshang 114 Industry Resources Network
全国服务咨询热线:
13062028296  13062028296


LC-3000 HPLC System (Single Pump)

价      格6800.00

最小起订1 Piece库存0 Piece

Location
Shandong Zaozhuang
有效期至
长期有效
最后更新
2022-03-24 09:23
View Count
85

Business Card

  • Your company's名称Shandong LuChuang Analytical Instruments Co., Ltd.
  • 联 系 人张文 (先生)
  • Your company'sPhone13062028296
  • Mobile号码13062028296
  • Company AddressNo. 39, Parallel North Road, Tengzhou City, Shandong (Taoyuan Garden Office Building)

买家正在看

  • Fully Automatic Headspace Sampler LCHS-42 Channels

    8800.00

  • GC-9870 Plus Full EPC Gas Chromatograph with Touch Color Screen

    58000.00

  • LCN-300 High Purity Nitrogen Generator

    6800.00

  • Luna Chromatograph GC-9870 Gas Chromatograph (EO Residue Detection)

    68000.00

Product Details
Manufacturer:
Array
Origin:
Shandong
Type:
High-Performance Liquid Chromatograph (HPLC)

I. Overview
The complete system consists of a P3000 high-pressure pump, UV3000 detector, sample valve, solvent tray, chromatography column, and operating software; installation, debugging, and use are all very simple.
2. The P3000 High-pressure Infusion Pump is a high-precision infusion pump system controlled by a single-chip microcomputer, with CPLD technology at its core. The all-digital frequency generator system, newly designed motor drive system, and user-friendly human-machine interface make operation very convenient. The newly designed pump head and single-valve design concept ensure the accuracy and repeatability of infusion under various conditions.
3. The UV3000 is a spectrophotometric detector that is compatible with any infusion pump, widely used in fields such as chemical analysis, pesticide, pharmaceutical, and chemical industries. It incorporates a fully digital and highly integrated design concept, significantly reducing instrument noise. Based on digital signal transmission and processing, the detector's signals can be directly input into the computer's serial port for collection, completely eliminating the need for traditional data acquisition cards!
II. Key Features
P3000 Series High-Pressure Analytical/Semi-Preparative Pump
Syringe method: Double plunger reciprocating pump, double plunger suction.
Display 320240-dot matrix large screen LCD display, blue backlit
System protection with slow start-up, stop, adjustable pressure, and automatic user data storage
System Connection 1/8" Pipe Connection
Control Independent Mode - Set all working parameters via the front panel buttons. Operate at high...
During pressure gradient mode, one pump serves as the main pump, controlling other pumps of the same model.
Infusion pumps, with gradient curves on the screen for adjusting the achieved gradient mode
Verify.
Serial Port Mode - Control high-pressure infusion pump via RS232 port
Power: 220V±10%, 50Hz, 400W
2. UV3000 UV/VIS Detector
Control Independent Mode via Front Panel Buttons
Serial Port Mode - Software controlled via RS232 port
Display 320240-inch large-screen LCD display with adjustable blue-backlight
Power Supply: 220V±10%, 50Hz, 60W
Dimensions and Weight: 398x149x267mm (Depth x Height x Width), 14kg
GLP Information: Total lighting hours, lighting counts, number of replacements, and product series numbers, etc.

Section 3: Technical Specifications of P3000 High-Pressure Infusion Pump

Infusion Method

Double-acting plunger pump, one main suction plunger. The other is an auxiliary plunger.

Pump Head

Analytical: 10ml stainless steel/PEEK pump head / Semi-prep 50ml stainless steel/PEEK pump head

Work pressure

Analytical: 42MPa stainless steel pump head / 30MPa PEEK pump head; Semi-preparative: 30MPa stainless steel pump head / 20MPa PEEK pump

Flow Range

Analytical: 0.001-9.999 ml Semi-preparative: 0.01-49.99 ml

Flow accuracy

RSD ≤ 0.5%(1ml/min)

Traffic redundancy

RSD ≤ 0.1%(1ml/min)

Display Screen

320*240 dot matrix large screen LCD display with adjustable blue back light.

System Protection

Slow start, stop below *low pressure 2ML. Both high and low pressures are adjustable, user data is automatically saved.

System Connection

1/16" pipeline connection

Control System

Independent Mode: Set parameters using the full keyboard. When operating in the high-voltage gradient mode, one of the pumps acts as the main pump, controlling other identical high-pressure infusion pumps, and verifying the displayed gradient method through the gradient curve on the display. Serial Port Mode: Control the high-pressure infusion pump via the RS232 port.

Note: Dimensions: 398*149*267mm, Weight: 10 kg, Power Supply: 220V ± 10%, 50Hz, 40W

 

 

Section 4: UV3000 Detector Technical Specifications

Wavelength Range/Accuracy

190 — 700nm   ± 2nm

Wavelength repeatability

0.4nm

Light Source

Deuterium lamp (standard configuration); Tungsten lamp (replaceable)

Light Source Control

Selectable light options, on/off settings

Scanning feature

Halt scan; scan programmable, allowing the start and end points to be set, as well as the scan step size.

Scope of Inspection

0 — 2AU

Baseline noise

1.5*10—5 AU/h; Flow rate: 1 ml/min; Methyl alcohol/Water ratio: 80/20; Wavelength: 254 nm

Baseline Drift

4*10-4 AU/h; Flow rate: 1 ml/min; Methanol/Water Ratio: 80/20, Wavelength: 254 nm

Time Constant

0.1/0.2/0.5/1/2/5/10S

Analog Signal

± 0.1V   ± 1.0V    ± 10V

Points Output

16 adjustable levels

Auto-zero

Full Range

Control

Independent Mode: Set parameters via full keyboard. Serial Port Mode: Control the high-pressure infusion pump via RS232 port.

Display Screen

320*240 pixel matrix large screen LCD display with adjustable blue backlight.

GLP

Total lighting time, number of lighting times. Number of light replacements and product series number, etc.

Note: Dimensions: 398*149*267mm, Weight: 10 kg, Power Supply: 220V ± 10%, 50 Hz, 40W

 

V. Configuration Description:

Serial Number

Order Number

Description

Quantity

1

LC-3001

P3000 High-pressure Infusion Pump

1

2

LC-3002

UV3000 UV Detector/Flow Cell for Analysis

1

3

LC-3003

Rehodyne Manual Sampling Valve 20UL Dosage Ring (USA)

1

4

LC-3004

CXTH-3000 Chromatography Workstation

1

5

LC-3005

Adjust C18 chromatographic column, 250*4.6, 10ul

1

6

LC-3006

Debugging Toolkit

1

7

LC-3007

Analytical Dynamic Mixer (Germany)                            Single-pump Type


8

LC-3008

Solvent Pallet

1

9

LC-3009

Solvent Filters, Vacuum Pumps, Ultrasonic (Essential for First-Time Use)

Each 1 (Select)


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
13062028296