The GC-9860 Gas Analyzer (All-in-One) is one of the typical detection instruments in China, utilizing low-power electronic information technology with new technology. The temperature control unit features an intelligent digital control instrument, and it is equipped with a dedicated thermal conductivity detector (TCD) and a specialized liquefied gas dimethyl ether detection column. The unit is highly integrated, microcomputer controlled, automatically sets parameters, requires no manual setup, and can start working immediately. It achieves high reliability and stability, is easy to operate, and convenient to maintain, widely used in liquefied gas production companies, storage and transportation stations, and sales companies.
I. Scope of Application
Detection of added gas content such as dimethyl ether, methanol, carbon monoxide, nitrogen in liquefied petroleum gas
② Detection of gas components such as liquefied petroleum gas, natural gas, and coal gas
③ Detection of Dimethyl Ether Purity
④ Detection of carbon dioxide, argon, methane, etc.
II. Main Technical Specifications
Main Box Temperature: Room Temperature +5 - 400℃; Accuracy ±0.1℃
2. Thermal Conductivity Detector (TCD)
① Sensitivity: s ≥ 3000 mv.ml/mg (Benzene)
②Basic Drift: 3%/h full scale
Section 3: Instrumentation Configuration
GC-9860 Gas Analyzer (Tri-Function): Hydrogen Generator + Thermal Conductivity Detector (TCD) + Built-in USB Chromatography Workstation
2. Computer Printer (Self-Assembled)
IV. Working Conditions
Ambient Temperature: 5℃-35℃
2. Relative Humidity: Below 85%
3. Supply Voltage: 220V ± 22V
4. Power Frequency: 50HZ ± 0.5HZ
5. Power Consumption: 500W
6. Free from strong electromagnetic fields, corrosive gases, intense vibrations, drastic temperature changes indoors, and significant air convection.
V. Technical Performance
1. Temperature Control: (Automatic: pre-set, no changes required)
Room temperature plus 5℃ to 400℃.
Temperature Control Accuracy: Not greater than ±0.1°C.
2. Detector Parameters (Automatic: pre-set, no changes needed)
3. Instrument dimensions and weight:
Host dimensions: 380×350×360 (L×W×H) mm.
Weight: Approximately 18 kg.