价 格¥6800.00
最小起订1 Piece库存0 Piece
Ethylene Oxide (EO) GC-9870 Gas C
¥68000.00/Piece
GC-9860 Transformer Oil Chromatog
¥68000.00/Piece
ATDS-800 Thermal Desorption Instr
¥6800.00/Piece
GC-9860 II Natural Gas Calorific
¥58000.00/Piece
Luna Chromatograph GC-9870 Gas Ch
¥68000.00/Piece
GC-9870 Plus Full EPC Gas Chromat
¥58000.00/Piece
GC-9870 Plus Full EPC Gas Chromat
¥58000.00/Piece
Fully Automatic Headspace Sampler
¥8800.00/Piece
GC-9860 Liquefied Gas Dimethyl Et
¥6800.00/Piece
LC-500 Binary High-Pressure Gradi
¥6800.00/Piece
I. Instrument Introduction
The ATDS-800 Pyrolysis Desorption Instrument is our company's independently developed and launched generation product, directly targeting a wide range of domestic and international users. This instrument is suitable for qualitative and quantitative analysis of various gases with boiling points below 350℃ in chemical construction materials, food, atmosphere, and indoor environments. It can be connected to any domestic or foreign gas chromatography or gas chromatography-mass spectrometry instrument. Its level of automation, repeatability, and sensitivity fully meet the new national environmental testing standards recently issued. Additionally, it boasts unique functional advantages and a satisfactory performance-to-price ratio. The fully automated design, touch screen display, and user-friendly operation make it even more convenient to use.
II. Instrument Features and Main Functions
1. The sample transmission pipelines are all made of imported high-inert gas scavenging lines, ensuring no residue or cross-contamination, thereby guaranteeing the reproducibility and accuracy of the sample intake.
2. Microcomputer program control, featuring main functions:
⑴ Method parameter settings, real-time display of working status, and running time.
The analysis area, sampling valve, and sample transfer tube are all individually heated and temperature controlled.
③ Set up the analysis program and press the run button to automatically complete the sample analysis.
④ Can be customized to a room temperature or low temperature secondary desorption unit according to customer requirements.
The GC and chromatography data processing workstation can be started simultaneously, or this device can be initiated by external programs.
3. The machine features an onboard standard sample simulation sampling function, which allows for more convenient preparation of working curves using the thermal desorption instrument.
4. Employed high-temperature six-way valves, capable of operation at temperatures up to 240°C.
5. Automate desorption, sample injection, and reverse-blow cleaning functions through time programming.
6. Sample transfer tubes and sampling valves feature an automatic back-flush function, preventing cross-contamination between different samples.
7. To enhance the convenience and accuracy of using this instrument with imported gas chromatographs, it is equipped with interfaces for various imported instruments, ensuring easy connections.
8. The connection point between the six-way valve and the transmission pipeline is located inside the heated insulation box, with no transmission cold points, ensuring the integrity of the sample.
9. Easy to replace syringe needles, compatible with all GC injection ports of domestic and international models.
10. Integrated design with a compact overall structure; microcomputer control with a full Chinese 7-inch LCD display, simple and convenient operation.
Section 3: Main Technical Parameters of the Instrument
Desorption temperature control range: Room temperature to 450°C, adjustable in increments of 1°C.
2. Valve inlet system temperature control range: Room temperature to 260°C, adjustable in increments of 1°C.
3. Sample transmission pipeline temperature control range: room temperature to 260°C, adjustable in increments of 1°C.
(Supplied with 24V low-voltage safe power)
4. Temperature Control Accuracy: < ±0.2℃
5. Desorption Recovery Rate: >99% (related to components)
6. Backflush cleaning flow rate: 0~500 ml/min (continuously adjustable)
7. Simulated Sampling Flow Rate: 0~160ml/min (continuously adjustable)
8. RSD: ≤2.5% (in 0.05 μg methanol, benzene)
9. Analysis Time: 0-60 min;
10. Sample Lead Time: 0-60 mins
11. Sample slot: 1 slot
12. Sample Tube Specifications: Diameter ≤ 6.5mm, Length ≥ 120mm.
13. Sampling Method: 6-way valve motor-driven.
14. Instrument dimensions: Length x Width x Height = 380mm x 230mm x 400mm³
15. Instrument Weight: Approximately 15kg
16. Power: 500W
Section 4: Instrument Application Scope:
"HJ/644-2013 Determination of Volatile Organic Compounds in Ambient Air — Sampling with Adsorption Tubes — Thermal Desorption Gas Chromatography-Mass Spectrometry"
"2. 'HJ/T400-2007 Method for Sampling and Determination of Volatile Organic Compounds and Aldehydes and Ketones in Vehicle Cabin'"
"GB/T18883-2002 Indoor Air Quality Standard"
4. "HJ/583-2010 Determination of Benzene Compounds in Ambient Air - Solid Adsorption/Thermal Desorption - Gas Chromatography"
5. "GB 50325-2002 Indoor Environmental Pollution Control Standard for Civil Engineering Construction" and others.
6. "HJ734-2014 Determination of Volatile Organic Compounds in Waste from Fixed Pollutant Sources - Solid Phase Adsorption/Thermal Desorption-Gas Chromatography" and others.

Phone Consultation