GC-9860 Transformer Oil Chromatog
¥68000.00/Piece
LCH-300 High Purity Hydrogen Gene
¥6800.00/Piece
ATDS-800 Thermal Desorption Instr
¥6800.00/Piece
Automated Pyrolysis Desorption In
¥6800.00/Piece
Honey Decenoic Acid Analysis Gas
¥68000.00/Piece
LCHS-20N Headspace Sampler
¥6800.00/Piece
Network Feedback Control Gas Chro
¥58000.00/Piece
Fully Automatic Headspace Sampler
¥8800.00/Piece
Luna Chromatograph GC-9870 Gas Ch
¥68000.00/Piece
Ethylene Oxide (EO) GC-9870 Gas C
¥68000.00/Piece
Key Technical Specifications
● Dual-language display technology, 5.7-inch LCD large screen (320*240). Up to 20 display interfaces, abundant information, capable of storing 20 sets of chromatography analysis data, and can be accessed at any time.
Industrial design with a novel and generous appearance, aesthetically pleasing and practical, with a reasonable structure and comfortable operation.
● Gas cut-off protection function, safeguarding the chromatographic column, thermal conductivity cell, electron capture detector, and more.
● The eight-stage linear programmable temperature ramping function and the intelligent double rear door design truly achieve near room temperature control with a temperature accuracy of ±0.1℃ to meet wide range analytical requirements.
● Enhanced over-temperature thermal protection and platinum resistance open-circuit/short-circuit alarm functions ensure the instrument remains undamaged.
● Self-diagnostic function with fault prompts in Chinese, conveniently informing users of the cause and location of the issue.
● Utilizes a FLASH memory system, ensuring data protection is no longer battery-dependent.
The microcomputer-controlled FID detector features an automatic ignition function.
● High-precision voltage and current stabilization mode ensures precise and stable airflow, achieving a multi-channel air pathway control system.
● High-performance capillary vaporization chamber, achieving a true分流/不分流injection system.
● Can install 1-4 detectors simultaneously. Operates in dual FID, dual TCD, dual ECD, or dual NPD configurations. The TCD features dual post-column makeup gas, allowing for single-column, dual-column, or capillary column use.
● The system can simultaneously install and operate 1-3 capillary columns and run 3 detectors concurrently. One instrument is equivalent to 3 (with shared column chambers). Alternatively, dual FID with dual capillaries. Dual TCD with dual capillaries. The dual TCDs operate simultaneously without interference, and the carrier gas can operate independently. This avoids the麻烦 of changing chromatography columns and detectors.
● The detector can be used in series or parallel configurations, with intelligent automatic switching controlled by events.
● The instrument can be equipped with various sample introduction methods, including a conversion furnace, pyrolysis desorption instrument, automatic sampler, automatic headspace sampler, and a pyrolyzer. It can be set to automatically sample at timed intervals, enabling automatic on-line analysis.
● Equipped with a variety of detectors, including FID, TCD, ECD, and FPD.
Technical Specifications
●Dimensions: 520×480×500mm (Length×Height×Width)
● Column box dimensions: 260×250×150mm (Length×Height×Depth)
Column Spacing for Chromatography Column: 152.4mm (6-inch Standard Interface)
Chromatography Column: External Diameter 3-5mm (Metallic or Glass Column)
● Instrument Weight: 50 Kg
● High Power: 2500W
● Voltage: 220 ± 10%
●Temperature Control Range of Column Box: Room temperature + 5℃ - 400℃ (adjustable with 1℃ increments)
● Temperature Accuracy: Not more than ±0.1℃
●Temperature Gradient: ±1% (temperature range 100℃-350℃) Programmed升温
● Heating Rate: 0.1-50℃/min (adjustable with 0.1℃ increments)
● Time Setting: 6000 (min)
● Program Grade: 8 Grades
Detector Technical Specifications
Hydrogen Flame Ionization Detector (FID)
● Detection Limit: Mt ≤ 2×10^-12 g/s (n-hexadecane)
Noise: ≤2×10^-14A (0.02mv)
Drift: ≤1.5×10^-13A/30min (0.15mV/0.5h)
● Linear Range: ≥10^7
● Operating Temperature: ≤450℃
Thermal Conductivity Detector (TCD)
● Sensitivity: S≥10000 mV.ml/mg (n-hexadecane)
Noise: ≤20μV
● Baseline Drift: ≤150μV/30min