One,FZ-G Model Fully Automatic Fermentation System Structural Description
(1) System Composition
Serial Number | Name | Specs/Model | Quantity | Note |
1. | Solid Fermentation Vessel | 10L-30KL | 1 | Material: Inner Tube SUS304/SUS316L |
Section 2: Equipment Function
Serial Number | System Equipment | Specs | Control Function | ||||||
Temperature | RPM | Sterilization | Pressure | Traffic | Acid and alkali | Supplementary Material | |||
1. | Solid Fermentation Vessel | Measurement and Control | Variable Frequency | Automatic | Measurement and Control | Manual | \ | \ | |
(3) Process matching
Serial Number | Name | Performance and Technical Specifications | Note |
3. | Vaccination | Atomized spray灌Vaccination | |
4. | Sterilization | In-situ Sterilization, Fully Automated Sterilization | |
5. | Intake | Equipped with distributors, micro-porous intake | |
6. | Agitator | Three-speed spiral scraper paddle blades, reversible cycle operation |
(IV)System Functionality
1. | Automatic Sterilization SIP | Content Control: Filter and In-tank Sterilization, Sterilization Timer, Overlimit Temperature and Pressure Alarm Automatically hold pressure and control temperature after sterilization to ensure the container remains sterile. |
2. | Temperature | Display Accuracy: 0.3%FS ± 0.1℃; Measurement Range 0-150℃ Content Control: Bi-directional heating and cooling temperature control Data recording, production curves, report analysis, data remote transmission |
3. | RPM | Control Method: Digital Variable Frequency Stepless Speed Control Actuator: Variable-frequency drive; Power: Matched with stirrer Data logging, production curves, report analysis, data remote transmission |
4. | Traffic | Control Method: Manual Control Actuator: Glass Rotameter |
5. | Pressure | Control Method:Automatic Control Testing Agencies: Pressure Transmitter + Proportional Control Valve |
6. | Dry | Control Method: Online Drying Actuator: Online vacuum extraction, vacuum drying |