One,FZ-G Type Full-Automatic Fermentation System Structure Description
(I) System Composition
Serial Number | Name | Specs/Model | Quantity | Note |
1. | Solid Fermentation Vessel | 10L-30KL | 1 | Material: Inner Tube SUS304/SUS316L |
(II) Equipment Function
Serial Number | System Equipment | Specs | Control Function | ||||||
Temperature | RPM | Sterilization | Pressure | Traffic | Acid and alkali | Supplementary Material | |||
1. | Solid Fermentation Vessel | Measurement and Control | Variable Frequency | Automatic | Measurement and Control | Manual | \ | \ | |
(3) Process matching
Serial Number | Name | Performance and Technical Specifications | Note |
3. | Vaccination | Aerosol SprayVaccination | |
4. | Sterilization | In-place sterilization, fully automated sterilization | |
5. | Intake | Equipped with distributors, micro-porous intake | |
6. | Agitator | Three-speed spiral belt scraper blades, reversible cycle operation |
(IV)System Functionality
1. | Automated Sterilization SIP | Content Control: Filter and Vessel Sterilization, Sterilization Timer, Temperature and Pressure Exceedance Alarms After sterilization, the system automatically maintains pressure and temperature control to ensure the canister remains sterile. |
2. | Temperature | Display Accuracy: 0.3%FS ± 0.1℃; Measurement Range: 0-150℃ Control Content: Dual Temperature Control for Heating and Cooling Data recording, production curves, report analysis, remote data transmission |
3. | RPM | Control Method: Digital Variable Frequency Stepless Speed Control Actuator: Variable-frequency Drive; Power: Matched with Stirrer Data recording, production curves, report analysis, remote data transmission |
4. | Traffic | Control Method: Manual Control Actuating Device: Glass Rotameter |
5. | Pressure | Control Method:Automatic Control Testing Institution: Pressure Transmitter + Proportional Control Valve |
6. | Dry | Control Method: Online Drying Actuating Mechanism: Online vacuum extraction, vacuum drying |