150L Programmable High and Low Temperature Alternating Humidity Test Chamber with Constant Temperature and Humidity
High/Low Temperature Alternating Humidity and Heat Test Chamber / Constant Temperature and Humidity Test Chamber

High-Temperature and Low-Temperature Alternating Humidity and Heat Test Chamber (HTA Series)
Application: Suitable for temperature and humidity testing of electronics, electrical, instruments, meters, automobiles, household appliances, various electronic components and parts, chemical raw materials, coatings, and plating, as well as adaptability tests under high and low temperature environments.
Key Features:
1.The outer shell is electrostatically powder-coated over cold-rolled steel, the inner lining is made of SUS304 mirror-polished stainless steel, and the design ensures no dead corners for easy cleaning.
2.French Taikang full-enclosed refrigeration compressors, refrigeration components (solenoid valves, filters, pressure controllers, oil separators, intermediate heat exchangers, etc.).
3.Utilizing the TEMI430 programmable temperature and humidity controller (optional RS485 communication interface).
4.The product features safety devices such as over-temperature protection, cold machine overload protection, over-voltage protection, and leakage protection.
5.The box door features a large-view observation window, with an indoor lighting system installed, allowing for real-time observation of the experiment on the test samples.
6.Install cable test holes/wiring holes for power-on testing of samples (the diameter size of the test holes is optional).
7.Product conforms to the GB2423.22-87 standard for high and low temperature test methods.
GB2423.4-93Alternating humidity and heat test method; Technical requirements for humidity and heat test chambers according to GB10586-89
GB10592-89High and low temperature test chamber technical specifications; GB2423.34-86 temperature and humidity combined cyclic test method.
Technical Specifications:
Model | High and low temperature alternating humidity test chamberHTASeries | |||||||
HTA-050 | HTA-100 | HTA-150 | HTA-250 | HTA-500 | HTA-1000 | |||
Volume | 50L | 100L | 150L | 250L | 500L | 1000L | ||
Temperature Control Range | LT-40 LT-60 | LT-40: -40~+150℃ Variable Range-30~+80℃ LT-60: -60~+150℃ Variable Range-50~+80℃ | ||||||
Temperature fluctuation | ≤±0.5℃ | |||||||
Uniform temperature control | ≤±2.0℃ | |||||||
Rise rate | ≥1℃/min | |||||||
Cooling rate | 0.7~1℃/min | |||||||
Humidity Range | 30%~98%R.H | |||||||
Humidity Accuracy | ±2~3%(75%R.H(above) ±5%(75%R.HBelow) | |||||||
Power Supply | AC220V/50Hz | AC380V/50Hz | ||||||
Rated Power | LT-40 LT-60 | 3.0KW 4.5KW | 4.0KW 5.0KW | 5.0KW 5.5KW | 6.0KW 6.5KW | 7.0KW 9.0KW | 8.0KW 10.0KW | |
Inner Diameter Sizemm | 350x400X400 | 450x500X500 | 500x500X600 | 520x600X800 | 700x800X900 | 1000x1000X1000 | ||
Dimension and Appearancemm | 720x890X1400 | 820x990X1600 | 870x960X1700 | 890x1090X1900 | 1070x1290X2040 | 1420x1490X2250 | ||
Optional Options:
Humidity and Temperature Controller: TEMI360, TEMI880, and TEMI990 (optional RS485 and RS232 communication interfaces)
TH-Standard with Ø50mm test holes, optional Ø80, 100, 120mm holes
HC-Heavy-duty partition (supports 50kg, standard load 15kg)
Please contact our sales representative for other sizes and features.