I. Overview of Portable Dust Detector
The HDL-FC-100B Portable Laser Dust Concentration Monitor (hereinafter referred to as the Portable Dust Monitor) is primarily used for the detection and alarm of dust particle concentrations (PM10 or TSP) in industrial and mining enterprises. This instrument draws in air containing dust particles from large public indoor spaces, industrial and mining enterprises, factory workshops, or production areas, and analyzes it using a high-precision laser dust detection sensor. The concentration value of dust in the space is displayed on the instrument's screen.
HDL-FC-100B Portable Laser Dust Continuously Monitoring Instrument, utilizing the principle of light scattering with a semiconductor laser as the measurement light source, for high-sensitivity, non-contact measurement of dust in the air. Managed and controlled by a single-chip microprocessor throughout the testing process, featuring a high-resolution, high-brightness LCD display with full Chinese characters.
II. Features of Portable Dust Monitor
This instrument is compact, easy to carry, boasts fast testing speed, high sensitivity, excellent stability, lightweight, simple operation, and dual AC/DC compatibility. Ideal for large factories and workshop environments. Ensures safe production and real-time monitoring.
Section 3: Applications for Portable Dust Monitor
1. HDL-FC-100B Portable Dust Monitor, suitable for rapid measurement of respirable particulate matter (PM10 or TSP) concentration in public places, industrial and mining production sites, and environmental protection areas for monitoring inhalable dust concentration. Also used for evaluating air purifier purification efficiency. Real-time dust concentration detection in production workshops, factory interiors, and other fields with alarm function.
2. The HDL-FC-100B portable dust monitor is equipped with a handle that can be freely telescoped and adjusted in position, facilitating the measurement of dust concentration inside various boxes, dust collectors, and flues.
IV. Technical Specifications
Dust Measurement Categories: PM10, TSP
Dust measurement range: 0.001~100.0 mg/m³
Detection Sensitivity: 0.001 mg/m³; Repeatability Error: ≤±3%
Air Sampling Flow: 2 L/min (0.1 ft³/min)
Sampling Time: 1 second to 100 minutes, manually adjustable at any interval. Directly read dust quality concentration (ug/m³).
Work Environment: Temperature (-30-75℃); Humidity RH (20-80)%
Power Supply: Integrated high-capacity lithium battery for over 2 hours of continuous operation, rechargeable for multiple cycles
Volume: 280mm x 210mm x 100mm
Weight: Approximately 4 kg
LCD Display
5. Portable Dust Detector Instrument Structure Diagram