Available in sizes from DN25 to DN1600mm for nine-wave compensators
Outer layer: Stainless steel metal mesh sleeve
Fatigue cycles: >= 10,000 cycles
Pressure Class: PN 0.25-2.5 MPa
Operating Temperature: <= 220°C
Compensator Installation Precautions
1. The installation of the compensator should be carried out according to the piping construction drawing and the compensator installation manual.
2. The pipeline installing the compensator must be properly guided and secured to ensure the compensator functions effectively. Therefore, the setup of guidance and support brackets must strictly follow the technical documents provided by the design department. For the principles of guidance and bracket setup, please refer to the "Wavy Compensator Installation Guide."
3. The bellows used in compensators are formed from thin-walled stainless steel plates. Therefore, during transportation, lifting, and welding, it is crucial to avoid damaging the bellows due to reasons such as knocking, scratching, sparking, and welding spatter.
4. Prior to installation, remove any foreign objects from the bellows and piping to ensure normal movement of the bellows.
5. Compensators with directional requirements should be installed according to the arrow indicating the medium flow direction.
6. To ensure the bellows is in good working condition, it cannot be adjusted by the compensator's deformation, including axial, lateral, and torsional, to correct the installation position errors of the pipeline system. 7. After the compensator is installed, all transport securing bolts painted yellow should be removed before the system is put into operation.
Jiangsu Zhongxin Bellows Co., Ltd. specializes in the production of expansion joints, bellows, butterfly valves, metal hoses, and more. Welcome to inquire and place orders from our extensive customer base!