    What to Pay Attention to When Using an Intelligent Vacuum Drying Oven

    2026-01-27

    The intelligent vacuum drying cabinet is designed for drying thermosensitive, easily decomposable, and oxidizable substances. It can inject inert gases inside, enabling rapid drying for items with complex compositions. Hot water or low-pressure steam is used as the heating medium to enter the heating plate. Place the drying tray for the drug on the heating plate, close the cabinet door, and use a vacuum pump to create vacuum. During the circulation of the heating medium, the heating plate heats the drug to the required temperature, causing water to evaporate and be gradually pumped away by the vacuum. The equipment is easy to control, can condense and recover the evaporated solvent, and the drug is less likely to be contaminated during the drying process. It is suitable for drug drying, packaging sterilization, and heat treatment. What should we pay attention to during the use of the intelligent vacuum drying cabinet?

    During the use of an intelligent vacuum drying cabinet, issues to be aware of include:

    No explosion-proof devices; explosive materials must not be dried.

    An excellent cross filter between the drying chamber and the vacuum pump to prevent wet bodies from entering the vacuum pump.

    Do not open the side door at will to avoid damaging the electrical system.

    The housing must be effectively grounded to ensure safe operation.

    5. When continuous exhaust is not required, the vacuum valve should be closed first, followed by turning off the vacuum pump power, otherwise the vacuum pump oil should be emptied into the box.

    6. Extracted items must be torn before processing. When dealing with flammable materials, they must be placed in the air only after cooling to a temperature below their ignition point to prevent oxidation reactions from causing a fire.

    The equipment should be equipped with an air switch.

    8. Electrical insulation must be intact, and the equipment housing must have a reliable protective grounding or protective zero connection.

    9. Vacuum pump oil should be changed regularly.

    When removing processed items, if flammable materials have been processed, they must be cooled to below their ignition point before being placed in the air to prevent oxidation reactions from causing combustion.

    11. When in use, a designated person must be present to ensure the proper operation of the equipment.

    When not in use for extended periods, remove items from the studio and clean them thoroughly to maintain the equipment's dryness.


Contact us

Hangzhou Chuanheng Experimental Instrument Co., Ltd.

Service Hotline

18758857552

Company Telephone

19106728583

WeChat Number

19106728583

Address

No Chinese content provided.


Message Consultation

 Click submit means you agree to《Service terms》《Privacy policy》

b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

 Click submit means you agree to《Service terms》《Privacy policy》