1. Brief Introduction:
Mixed gas test chamber is used for accelerated corrosion testing of contact points and connectors, to evaluate the corrosion effects of the atmosphere contaminated by sulfur combustion products on contact points and connectors.
The test chamber utilizes gases such as H2S, SO2, NO2, CI2, etc., to accelerate corrosion of materials or products under specific temperature and relative humidity conditions, reproducing the corrosion effects of materials or products over a certain period of time.
The extent of damage within the scope and a comparison of the process quality of similar protective layers, assessing the protective coatings of industrial products such as automotive parts, electronic components, metal materials, and electrical products in a mixed gas environment.
Corrosion resistance in the body.
2. Meets Standards:
IEC60028-2-60 (GB/T2423.51-2020) Environmental Test for Electrical and Electronic Products - Test Ke: Corrosion Test by Flowing Mixed Gas
IEC 60068-2-42 (GB/T 2423.19-2013) Hydrogen Sulfide Corrosion Test for Contact Points and Connectors
IEC 60068-2-43 (GB/T 2423.20-2014) Hydrogen Sulfide Corrosion Test for Contact Points and Connectors
IEC 60512-11-7 (DIN EN 60512-11-7) Corrosion Test of Flowing Mixed Gases
GB/T19745-2005 and QC/T417.1-2001, Article 4.24 requirements for flowing gas corrosion test
IEC68-2-60 Test for corrosion caused by artificial low concentration pollutants
EIA-364-65B Method for Mixed Gas Corrosion Testing
3. Key Technical Parameters:
3.1 Model
ZT-H150 ZT-H300 ZT-H600 ZT-H1000
3.2 Studio Dimensions
ZT-H150A 500w x 500d x 600h mm
ZT-H300A 650W x 650D x 710H mm
ZT-H600A 800W x 800D x 940H mm
ZT-H1000A 1000W x 1000D x 1000H mm
3.3 Equipment Dimensions
ZT-H150A 1360W x 1250D x 1800H mm
ZT-H300A 1550W x 1400D x 1900H mm
ZT-H600A 1600W x 1650D x 2000H mm
ZT-H1000A 1800W x 1850D x 2050H mm
3.4 External Dimensions of Exhaust Treatment Unit
ZT-H150A 760W x 680D x 1500H mm
ZT-H300A 760W x 680D x 1500H mm
ZT-H600A 880W x 750D x 1650H mm
ZT-H1000A 880W x 750D x 1650H mm
3.5 Cylinder Storage Dimensions Outside Cabinet
ZT-H150A 950W x 450D x 1200H mm
ZT-H300A 950W x 450D x 1200H mm
ZT-H600A 950W x 450D x 1200H mm
ZT-H1000A 950W x 450D x 1200H mm
3.6 Power/Power Supply
ZT-H150A 220V, 4.5kw
ZT-H300A 380V, 6.0kw
ZT-H600A 380V, 8.0kw
ZT-H1000A 380V, 9.5kw
3.7 Temperature Range:15℃~60℃
3.8 Relative Humidity Range:50~90% RH
3.9 Uniformity of Temperature:≤2℃ (Idle state constant)
3.10 Temperature Fluctuation:±0.5℃ (no-load steady state)
3.11 Temperature Deviation:±1℃ (no-load steady state)
3.12 Humidity Deviation:±3% (no-load steady state)
2.13 Sulfur Dioxide Concentration:10ppb to 30ppm (by volume)
3.14 Hydrogen sulfide concentration:5ppb to 15ppm (by volume)
2.15 Nitrogen Dioxide Concentration:100ppb to 500ppb (by volume)
3.16 Chlorine Gas Concentration:5ppb to 50ppb (by volume)
3.17 Gas Concentration Control Method:Import the method of volume ratio calculation via formula, then control the gas flow
3.18 Sample Rack:Swivel and fixed bracket mounts
3.19 Time Setting Range:0 to 9999 hours (touch screen)
3.20 Air Changes Per Hour:3-10 times adjustable (touch screen setting)
3.21 Verification of Gas Concentration:Gas concentration test tubes and test strips (options include gas collectors, concentration test tubes, and test strips)