Zhejiang Hongsheng Electrical Co., Ltd.VIP

直流屏厂家、eps消防应急电源、应急照明集中电源箱
Enter Shop

Fire Pump Inspection Cabinet

平台认证
  • Unit Price

    Negotiable

  • Brand

    Hong Sheng

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



浙江鸿圣电气有限公司

VIP   采商通第1年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Hong Sheng

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0

  • Address:

    ZhejiangWenzhou

  • Delivery:

    0Hours

  • View More

Description


With the rapid development of cities and the increasing number of buildings, the extensive use of flammable materials, coupled with a lack of fire safety awareness among people, this significantly raises the likelihood of fires. Although every building is equipped with a fire extinguishing system, experience and lessons have shown that the success of extinguishing a fire largely depends on the integrity of the fire供水 equipment. Fire pumps are a crucial component of the fire suppression system, characterized by their long-term non-use, yet they must perform 100% when activated. Due to their prolonged disuse and the damp environment in pump rooms, it's common for fire pump shafts and impellers to rust and seize, as well as for electrical components to malfunction. This can lead to the fire pump failing to operate properly during a fire, rendering it unable to extinguish the flames and posing a threat to people's lives and property safety.

To address these fire safety challenges, our company has independently developed an integrated intelligent fire inspection system - the fire pump inspection cabinet, which combines alarm, surveillance, control, and management functions. It has been mass-produced and put into use. This product prevents rust, dampness, and abnormal operation of fire pumps, achieving the goal of "training soldiers for a thousand days and using them at a moment's notice." The product complies with the mandatory industry standard issued by the Ministry of Public Security, "Performance Requirements and Test Methods for Fixed Fire Water Supply Equipment (GA30.2)" and standard GB16806, and has passed the CCCF mandatory certification.

Application Environment

1. Environmental Temperature: 0~+40℃

2. Environmental Humidity: 0~90% without condensation

3. Altitude: Less than 1,000 meters

◆ Product Features

1. Utilizing variable-frequency speed controllers for pump inspection reduces start-up current and maintains lower pump speed, minimizing mechanical shock to the pump. This extends the service life of fire pumps, especially significant for high-power pumps.

2. The variable frequency inspection drive has a low power consumption, operates efficiently, and its power is approximately 1.35% of the power frequency inspection power, significantly saving electricity resources.

3. The fire patrol cabinet can automatically conduct inspections at set intervals without manual operation. Equipped with various communication interfaces, it enables remote fire monitoring and allows for real-time awareness of the status of the fire pump units, facilitating management.

4. Equipped with a large Chinese LCD touch screen as the human-machine interface, operation is convenient and straightforward.

5. The controller utilizes advanced domestic PLC technology, ensuring stable performance and reliable safety.

6. Equipped with fault alarm, power failure flash memory function, and fault storage record capability, it can store up to 256 fault records, facilitating maintenance personnel for inspection and fault analysis.

7. In the process of inspection, upon receiving a fire alarm, immediately exit the inspection and promptly start the fire hydrant and sprinkler pumps.

8. The fire inspection device features comprehensive interface functions, enabling it to connect with the corporate monitoring center or the public security and fire department's computers. It provides real-time monitoring and detection of the equipment 24/7, achieving remote computer monitoring and all-around network center management, thereby further enhancing safety surveillance.

9. The fire inspection device is easy to wire and can be matched with control cabinets produced by any switch factory.

Application Range

This system is suitable for residential communities, production bases, office buildings, shopping malls, hotels, inns, schools, warehouses, hospitals, and more. It is also ideal for retrofitting old fire protection projects, effectively utilizing existing fire equipment, and saving costs for users.

Features Menu

Inspection Cabinet Function

Method

Inspection Cabinet Function

Method

Inspections can be conducted on a cyclical basis as set.

Self-contained

Print Function

Customized

Low-speed, low-frequency, pressure-free inspection on a per-unit basis

Self-contained

Pipe Network Protection Function, Pressurized Inspection Function

Customized

Upon fire alarm, exit inspection immediately and switch to operational status.

Self-contained

SMS Alert Feature

Customized

Audio and visual alarm function

Self-contained

Features RS485 communication capability, compatible with fire alarm system networking

Customized

Fault Storage Record Feature

Self-contained

Water Level and Pipeline Water Pressure Alarm Function

Customized

Overvoltage, overcurrent, short circuit, and under-voltage protection functions

Self-contained

Voice Broadcast Feature

Customized

Year, Month, Day - Countdown Display

Self-contained



Appendix: Section 4 of Article 5 in "Performance Requirements and Test Methods for Fixed Fire Water Supply Equipment GA30.2" specifies the inspection function.

Fire pumps that are in a non-operational state for extended periods should be equipped with a patrol inspection function and should meet the following requirements:

5.4.4.1 The equipment should be equipped with both automatic and manual inspection functions, with the automatic inspection cycle capable of being set as required.

5.4.4.2 Fire pumps operate individually according to fire-fighting methods, with each pump running for at least 2 minutes.

5.4.4.3 The equipment should automatically exit the inspection process and enter fire protection operation mode upon receiving a fire alarm signal during routine inspections.

5.4.4.4, Faults discovered during routine inspections should trigger audible and visual alarms. Equipment with fault memory function should record the type of fault and the time of occurrence, with at least [number] fault information entries, and the display should be clear and easy to understand.

5.4.4.5 The equipment using power frequency for inspection should have anti-overpressure measures. For equipment with inspection pressure relief circuits, the circuit settings should be safe and reliable.

5.4.4.6 Electrically operated valves used for regulating water pressure should be included in the inspection routine.

Section 5 of GB27898-2011: Fixed Fire Water Supply Equipment stipulates:

5.4.5.1. The equipment should be equipped with manual inspection and inspection reminder functions, and the inspection reminder cycle should be adjustable as needed, but the longest cycle must not exceed 360 hours.

5.4.5.2. The operation method for inspection rounds should be simple and should be specified in the "Operation Manual."

5.4.5.3. During inspection, the fire pumps should be started and operated one by one, with each pump running for at least 2 minutes under rated conditions.

5.4.5.4. Faults detected during inspection should trigger an audible and visual alarm.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery ZhejiangWenzhou
Brand Hong Sheng
Brand Hongsheng
Quality Quality Assurance
Service Service Priority
Expiry Long Valid
Update 2025-06-19 16:18
Gallery

Zhejiang Hongsheng Electrical Co., Ltd.Published byFire Pump Inspection CabinetGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top