Prior to shipment, ensure the water supply, drainage, and gas piping are properly connected. Upon shipment, each steam generator's water capacity is less than 30L, falling within the scope of boilers that do not require approval, thus no boiler permit is needed. The furnace is equipped with an internal steam-water separator, effectively reducing the moisture content in the steam and enhancing steam quality.
Demand-based activation, individual control for greater energy efficiency: Start different numbers of electric steam generators based on steam demand, thus avoiding the waste of low load operation of large boilers, which can save operation costs by over 10%.
Advantages and selection points of electric steam generators:
Safety of electrically heated steam generators:
Leakage Protection: In the event of a leakage in the boiler, the circuit breaker is promptly activated to disconnect the power supply, ensuring personal safety.
② Low Water Protection: In the event of boiler water shortage, the heating tube control circuit is promptly disconnected to prevent damage due to dry burning of the heating tube. At the same time, the controller emits a low water alarm indication.
③ Grounding Protection: When the boiler shell is electrified, the leakage current is channeled into the ground through a grounding wire to ensure personal safety. Typically, the protective grounding wire should be well-connected to the ground with metal, often using deeply buried angle irons or steel pipes as grounding bodies, with the grounding resistance not exceeding 42 ohms.
④ Steam Overpressure Protection: When the steam pressure in the boiler exceeds the set upper limit, the safety valve activates, releasing steam to reduce the pressure.
⑤ Overcurrent Protection: In the event of the boiler operating at overload (high voltage), the leakage circuit breaker will automatically trip.
⑥ Power Protection: The electronic circuit reliably shuts off power upon detecting faults such as overvoltage, undervoltage, and power interruptions.
Electrically heated steam generator performance features:
1. Automatic Control. One-touch start-up, effortless operation. Automatic Pressure Control. Full automatic operation with set start-up and shutdown pressures. The equipment runs automatically, as long as there's water and electricity.
2. Safety: In addition to roommate water shortage protection, low water level protection, and electric leakage protection, we also have power abnormality protection and over-pressure protection, ensuring the safe operation of the equipment.
3. Zero emissions, zero pollution. Environmental certification is a must, and the electric steam generator meets this requirement, providing zero-emission, zero-pollution steam equipment.
4. Noiseless, silent operation.
5. The evaporator body's water capacity is less than 30L, no boiler operation permit is required.

Electric steam generators have a wide range of applications: blow molding machines, road and bridge T-beams, box beams, tunnel construction, concrete curing, boiler for cement components, high-temperature sterilization, biological research, factories, pulsation, cooking medicine, reaction vessels, double boiler, garment factories, dry cleaning shops, laundries, garment pressing and washing, school and unit laboratories, research institutes, vegetable greenhouse heating, chemical factories, food processing, making tofu, boiling soy milk, steaming buns, steaming mantou, making cold noodles, steaming rice noodles, tea factory tea production, fermentation, spicy pot, stone pot fish, hotpot, hotels, steamed dishes, sugar熬煮 food.
The grounding wire of the steam generator is crucial for safety of use, and thus a reliable grounding wire should be installed. The grounding wire should be driven into the ground nearby with a depth of ≥1.5m, and the cable connection heads should be fused onto the grounding stake. To prevent rust and moisture, the connected joints should be elevated above the ground by 100mm.