Japan UNIPULSE Weight Controller Agent. UNIPULSE -F377A Specifications. Japan UNIPULSE After-Sales Support
F377A is a sensor combination that utilizes the same voltage and current sensing method to measure various forces.
A dynamometer that measures physical quantities such as pressure and torque, displaying their waveforms.
Connectable to voltages ±10V, current ±20mA.
It's just that the physical quantity changes are difficult to capture with numbers; waveforms can be visually displayed to do so.
Received explicit confirmation.
A processing capability of 2,000 times per second ensures timely reflection of even the smallest numerical changes, in addition to...
In addition to the upper and lower limit comparison feature, it also offers various maintenance and judgment functions, these
The feature enables its wide application in areas such as production control management, automatic instruments, and testing machines.
Application.
Simulated Partial Voltage Input: -10~+10V Input Impedance: Over 1MΩ Current Input: -20~
+20mA Input Impedance: Approx. 250Ω Analog Filter LPF (Bessel Low-Pass Filter)
(-6dB/oct.)
Select A/D converter speed between 30, 100, 300, and 1000 Hz: 2000 times per second
Resolution: 24-bit (binary)
Effective Resolution: Approximately 1/30,000 analog voltage output at 10V or 20mA
Output Level: Approximately 0.6V when input is 1V, or approximately 0.3V when input is 1mA.
Load Impedance: Over 2kΩ


3.5-inch TFT Color LCD Display Module with Display Area of 71(W)
mmx53 (H) mm pixel dots form a 320X240 dot display value range: -99999 to
+99999 Symbol: The first digit displays as a minus sign
Set partial comparison settings for upper limit, limit, lower limit, sub-lower limit, lag, alert upper limit.
Alarm Lower Limit, near Zero, Compare Time, Compare Output Selection Maintain Setpoint Mode
Start of inspection level, monitoring time, level inspection conditions, sample point movement, inspection completed
Level, average sampling times, change point determination value, pre-change point detection time, variation
Set the detection time after decimation, the movement of change points, the start condition for detection, and the extreme value detection limit.
Low value, limit value detection ratio graphic setting graphic mode, starting point on Y-axis (load)
Axle (Load) Endpoint, X-axis (Time) Endpoint, Descriptive Starting Level, Impedance Time, Trace
Set up simulation input selection for drawing start level condition calibration, zero point calibration, equivalent input calibration.
Physical Calibration, Calibration Value Selection, Unit, Digital Zeroing, Decimal Point Separation
Motion settings: Digital Filtering, Analog Filtering, Backlight Lighting Time, Language Switch, SI/F Signal
Dynamic monitoring, zero-point drift, screen output filtering, displayed value color, B5 power
Select, B6OFF Detection Wait Time, B8OFF Detection Wait Time, Measurement Workpiece Input
Toggle, control input switching, set RS-232C communication mode, baud rate, character length
Stop position, terminator, header character, pre-comparison of data stream control extension, one-time numerical comparison
Relative value comparison retention with two points of extension maintained, automatic reset switching, value update retained.
Sample trigger switching, maintain function release at DZ, graphic expansion at end of maintenance
Puritoriga exhibits action expansion digital filtering characteristics, DZ for average time, RUN for output shape.
Selective component extension to form BCD output data
Maintain Function Overview: 1. Sampling 2. Peak 3. Valley 4. P-P 5. Average 6. Inflection Point 7. Maximum
Value: 8. Minimum Value