Product Information

MP-SPR Navi™ 400 KONTIO is particularly suited for research on living cells. Equipped with a 4-channel PDMS flow cell. Semi-automatic operation: fully automated liquid flow, manual valve control. 2 peristaltic pumps (each with two channels). Parallel or series mode selectable.


Application Fields

Solid Film

Solar cells, displays, food packaging, preservative, antibacterial, anti-reflective coating functionality - MP-SPR assists in maintaining functionality while reducing coating thickness. MP-SPR can both measure interactions and assess the surface plasmonics, thickness, and complex refractive index of ultra-thin metal coatings ranging from 3Å to 100nm.

Soft Materials

MP-SPR measures the interaction between other substances and polymers, which can range from ultra-thin films to 5μm thick films. MP-SPR is the most sensitive unlabelled technique for studying the interaction and characterizing layers of biomaterials. MP-SPR aids in optimizing barrier layers, including: functional moisturizing, pH control, anti-reflective, stain-resistant, and antimicrobial coatings.

Sensor Development

The MP-SPR is adjustable for detecting specific gas or liquid components. It can detect hydrogen on a palladium surface (2Da) or cocaine in saliva. MP-SPR is used for the development of point-of-care (POC) testing and for testing surface treatments of microfluidic materials.

Nano particles

MP-SPR is a good choice for characterizing nanoparticles, be it metals, silicon dioxide, polymers, or other types. Obtain "before and after" images using SEM or AFM. With MP-SPR, observe the dynamics, targeting, release, or internalization of self-assembly in real-time.

Electrochemical

MP-SPR can be coupled with various electrochemical methods, such as potentiometry, amperometry, or impedance spectroscopy. This enables the simultaneous and real-time monitoring of (electro)chemical reactions on the sensor surface without any labels.

Antibody Characterization

Affinity and kinetics of antibody-antigen interactions can be measured in a variety of liquids, including complex ones like sera, urine, or saliva.

Biological Sensor Development

From nanoparticle-based competitive analysis to electrochemical sensors, up to direct analysis methods, MP-SPR displays all steps of the analytical process and can develop biosensors on glass, polymers, silicon dioxide, metal surfaces, or nanoparticles.

Biological Materials

MP-SPR measures interactions on polymers with thickness up to 5μm. MP-SPR is the most sensitive unlabelled technique for studying biological material interactions and characterizing layers. It can optimize: novel coatings for cell and tissue engineering, and new industrial protective coatings.


Technical Specifications

Measurement PrincipleReal-time and unmarked multi-parameter surface plasmon resonance (MP-SPR) is a SPR device based on actual angle measurement, equipped with a rotating laser and detector.
Wide angle measurement range: 40° - 78°, true angle resolution: 0.001.
Liquid TreatmentThe蠕动泵 controls the flow rate of the controlled release liquid, with a flow rate range of 10ul/min to 400ul/min. It features 4 flow channels and a manual sample injector.
Sample consumption quantityTypical sample quantity required: 200μl - 500μl. Sample quantity can be further adjusted by replacing the sample ring.
Laser Wavelength4 flow channels are all standard wavelength: 670 nm.
Each flow channel is equipped with 2 beams of laser (670nm and 785nm) via the additional L-Option. Other wavelengths available upon request.
Simultaneous thickness and refractive index measurement is achieved with an additional wavelength.
Refraction range1.00-1.40 (measuring the environment of the unit), expandable with additional wavelengths.
MP-SPR can measure layers with higher refractive indices (RI), such as diamond-like (2.7) and inorganic crystals.
MP-SPR can also measure the birefringence of liquid, gas, and solid layers.
MediumA full scan includes two environments: gas and liquid.
Measurement is conducted not only in aqueous solutions but also in organic liquids, such as ethanol and acetonitrile. For compatibility with other organic liquids, please inquire with us. PureKinetics™ can correct for differences in running buffer and sample composition, even differences as significant as 5% DMSO!
Operation ModeAngle scan mode, "MP-SPR mode": Scans a series of angles, providing a full SPR curve and multiple parameters. Several sensor spectra can be extracted from the complete SPR curve, such as PureKinetics™.
Sample rate depends on the selected angle range and resolution, typically less than 2 seconds.
Fixed Angle Mode, "Traditional SPR Mode": Measures at a single angle, providing a time-intensity detection spectrum.
Pattern for research of rapid dynamics - sampling rate up to 1 ms.
Measurement RangeThickness: From angstrom to micrometers (specific range depends on the refractive index of the material)
Dynamics: ka = 103– 1081/(M*s),kd = 10-7– 0.11/s,KD = 10-12– 10-3M
Sensitivity1μRIU (refractive index); 1pg/mm2(Protein surface coverage); Smallest detected molecule: in the gas phase, hydrogen (2 Da); in the liquid phase, smallest molecular weight < 100 Da
NoiseShort-term noise: 0.3 μRIU, baseline drift (long-term) < 1 μRIU/min
TemperatureTemperature Measurement Range: 15℃–45℃ (Room Temperature +20℃/-7℃)
PrismPrisms with matched adhesives enable quick sensor replacement, prevent sample contamination from refractive index matching oil, and allow for further sample analysis by other means. No need for refractive index matching oil or expensive gold-plated prisms.
Flow poolEasily replace the flow tank with a single release button.
Standard Flow Cell: PDMS material, each channel volume 1 μl.
Optional Flow Cells: SPR305-MS, larger diameter and high chemical resistance PEEK flow cell; SPR321-EC, electrochemical flow cell; SPR310-GS:
Gas Flow Cell; SPR302-LS: For rapid kinetics research; or customized flow cells upon request.
Sensor/SubstrateOffer a wide range of surfaces, such as: metals (Au, Ag, Cu, Pt, etc.), other inorganic substances (SiO2, etc.).2,Al2O3,TiO2, etc.) or functionalized surfaces (CMD, Ni, etc.)2+Protein A, Biotin, Strepavidin, disulfides, etc.
Chip holder achieves non-in-situ deposition on the sensor surface (e.g., dipping coating).
If you can't find the sensor you need, we can provide a custom one upon request.
SoftwareUnlimited MP-SPR Navi™ Control and DataViewer software.
Easily export data to Excel or utilize our proprietary analysis tools.
Optional LayerSolver™ fitting tool for layer characterization and/or TraceDrawer™ software for dynamic analysis
MaintainNo service contract required, unless you prefer one. HPLC piping makes it easy to replace fluid components.
Computer requirementsWindows 7, 8.1, or 10, 1x USB 2.0, 4GB RAM, 10GB hard drive (1GB for installation, remaining space for measurement data)
Power Requirements100-240V,50/60Hz,Max. 40W  
Principle of MeasurementReal-time and unmarked multi-parameter surface plasmon resonance (MP-SPR) is an SPR device based on true angle measurement, equipped with a rotating laser and detector.
Wide angle measurement range: 40°-78°, true angle resolution: 0.001.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery BeijingPre-sale, after payment90dayswithin
Stock 100TaiMOQ1Tai
Brand BioNavis
Application Fields Solid thin films, soft matter, sensor development, nanoparticles, electrochemistry, antibody characterization, biomaterials
Model MP-SPR Navi™400 KONTIO
Brand BioNavis
Expiry Long Valid
Update 2023-04-22 13:46
Gallery

Beijing Zhengtong Yuanheng Technology Co., Ltd.Published byMP-SPR 400 Molecular Interaction Analyzer KONTIOGallery Lib