Magnetic Resonance Hydrostatic Level Gauge, High Precision, Excavation Pit, Tunnel, Railway, Highway, Settlement Monitoring, Outdoor Installation, PT500-SZY20

Product Overview:

Utilizing imported waveguide fiber and core materials.

52mm diameter 304 stainless steel float + 304 ball float rod

Integrated aluminum alloy housing, fully sealed and waterproof structure.

Matching liquid inlet holes, exhaust valves, level gauges, mounting brackets.

10mm tube connection quick plug; M12 waterproof connector.

High precision, stable, digital amplification circuit; Zero point, full scale, temperature compensation, linear compensation.

MODBUS RS485-RTU Digital Signal Output

Alternative to foreign similar hydrostatic level instruments.

Custom outdoor waterproof connection pipes; anti-freeze fluid and liquid tubes, as well as RS485 communication cables.

Supply PT500-990 wireless 4G data collection module and third-party monitoring platform as required.

As required, provide locally compatible supervisory software.


The PT500-SZY20 Magnetic Inductive Hydrostatic Level Gauge is primarily used for:

Railway track subgrade, subway support wall settlement monitoring

Tunneling and building settlement monitoring above the hillside.

Highway subgrade, slope, and pier settlement monitoring

Excavation, nuclear power plant, and hydroelectric power plant settlement monitoring.

Dam and hydraulic枢纽的基础沉降 monitoring for high-rise buildings

Bridge, foundation, and tunnel safety management;

Grip parameters such as the environment, traffic, structural stress, and deformation of the monitored object.

Real-time assessment of bridge operational status and prediction of functional changes in the bridge.

Assess signs and trends of structural performance degradation to enable maintenance units to take timely maintenance measures.

Measure the settlement of the support base, measure the expansion joint changes

Measure anchor plug displacement

Model Naming:

PT500-SZY20-100mm-RS485


PT500: General Quantity Category

SZY20: Model Specification

100mm: Travel Range

RS485: Output Signal


PT500-SZY20 Magnetic-Inductive Linear Variable Differential Transformer (LVDT) Hydrostatic Level Gauge Main Technical Parameters:

Range: 0-100mm; 200mm; 300mm;

±0.1mm;

Non-linear: ≤0.05%FS

Repeatability: ≤0.002%FS (1μm)

Output Signal: RS485-RTU

Update Frequency: 10 Hz

Supply Voltage: 24VDC (9-30VDC)

Working Current: <50mA (varies with range)

Life span: ≥1 million cycles

Insulation Resistance: ≥1000 MΩ/100VDC

Ambient Temperature: -40~70℃

Humidity/Dew Point: 90% humidity, no condensation

Temperature Coefficient: <30ppm/°C

Electrical Connections: M12 Waterproof Electrical Connectors

Process Connection: 10mm Liquid Tube Quick Connector

Protection Class: IP67

Connectivity Cable: 5-core shielded cable, Standard Length: 1 meter

Dimensions: 100*100*277

Buoy Specifications: 304 stainless steel, 52mm diameter large buoy ball

Applicable Medium: Water or antifreeze and other liquid substances (ensure the liquid does not freeze based on the environmental temperature of the application installation area)

Measurement Principle and Installation:

The hydrostatic level system, also known as a connecting tube level instrument, consists of at least two observation points, with each point equipped with a hydrostatic level instrument. The storage containers of the hydrostatic level instruments are completely connected by a fluid conduit. Inert liquid is injected into the storage containers. Once the liquid surface is completely still, the liquid surfaces in all connected containers within the system should be at the same geoid level. At this point, the liquid level in each container is measured by the sensor, with the initial liquid level values being: H10, H20, H30, H40.


As shown:

Settlement Calculation:

Assuming the measurement point 1 as the reference point, with point 2 experiencing ground settlement, point 3 experiencing ground uplift, point 4 with no change, etc., after the liquid level in the system reaches a balanced state, a new datum level Vi0 is formed. The new liquid level values in the connecting containers at each measurement point will be: H1, H2, H3, H4, and the respective liquid level change amounts will be calculated as:

△h1=H1-H10        △h2=H2-H20

△h3=H3-H30        △h4=H4-H40

When point 1 is selected as the reference point, the vertical displacement (subsidence) of other measuring points relative to the reference point is:

△H2=△h1-△h2          △H3=△h1-△h3          △H4=△h1-△h4


As shown:




Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1650.00 / Set
Sales None
Delivery GuangdongFoshanPre-sale, after payment5dayswithin
Stock 200SetMOQ1Set
Brand Standard Quantity
Range 0-100/200/300mm
Output RS485-RTU
Accuracy 0.1mm
Expiry Long Valid
Update 2023-06-25 08:06
Gallery

Foshan普量电子有限公司Published byMagnetic Inductive Level Gauges - Excavation, Tunnel, Railway, Highway, Settlement Monitoring - Outdoor InstallationGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top