Siemens ET200SP Interface Module

平台认证
  • Unit Price

    Negotiable

  • Brand

    Siemens

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



上海中恒科联自动化设备有限公司

VIP   数字营销第4年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Siemens

  • Unit Price:

    Negotiable

  • MOQ:

    MOQ1Tai

  • Total:

    90Tai

  • Address:

    Shanghai

  • Delivery:

    3days

  • View More

Description

Siemens ET200S Interface Module, Siemens ET200S Module, Siemens ET200S, ET 200SConnected through the interface modulePROFIBUSOr industrial EthernetPROFINETWithin the bus system.ET 200SInterface modules are available in various types, including those with applications in standard systems.CPUOr not equipped withCPUAvailable, as well as the corresponding fault types.


Additionally, there is the corresponding wide-temperature version (SIPLUS). Siemens ET200S interface module, Siemens ET200S module

Integrated CPU Interface Module

The integrated CPU interface module can be used as a standalone controller, and also applied in distributed automation systems with medium-scale programs at each substation. Its processing capability is equivalent to the CPU 314 of S7-300, allowing for on-site distributed preprocessing of production data. Communication can be via MPI/PROFIBUS or PROFINET, depending on the model. The interface module offers the following advantages:

• Relieve the controller's burden

Reduce response time to critical local data

• Increased transparency and streamlined procedures

• Easier debugging

• Smaller bus system load

Modular system structure, with pre-commissioning capabilities at various locations

Interface modules with integrated CPUs are available in the following types:

• The IM 151-7 CPU and IM 151-7 CPU FO communicate as PROFIBUS DP slave stations and upper-level controllers. By adding the DP master station module IM 151-7, a DP master station interface can be expanded, enabling the establishment of a lower-level PROFIBUS distributed system.

• The IM 151-8 PN/DP CPU offers both PROFINET and PROFIBUS interfaces. As a PROFINET IO controller, it can connect up to 128 IO devices. The PROFINET interface integrates three switch ports, enabling linear or ring topologies. Like the IM 151-7, it can connect an additional 32 PROFIBUS DP slave stations by adding a DP master station module.

In terms of faults, the SIMATIC ET 200S intelligent interface module IM 151-7 F-CPU and IM 151-8 PN F-CPU can be used to meet applications with moderate performance requirements. Fault-type CPUs can be expanded into centralized applications with ET 200S I/O modules or constructed into distributed systems via PROFIBUS or PROFINET. The intelligent ET 200S can also be used as a standalone controller without connecting to PROFIBUS or PROFINET cables. The IM 151-7 F-CPU and IM 151-8 PN F-CPU can also be equipped with a PROFIBUS DP master station module, functioning as a standard controller or an independent CPU (including type modules).

The IM 151-7 F-CPU incorporates DP/MPI interfaces. The IM 151-8 PN/DP CPU features a PROFINET interface with three switch ports, allowing for easy linear or ring topologies with two ports, and the third port for connecting programming devices. Additionally, with the built-in webserver functionality, module access and diagnostics are conveniently available. Both modules meet SIL 3 (IEC 61508, IEC 62061) and Cat. 4 (EN 954-1) requirements.

Interface Module without CPU

The interface module connects the ET 200S to the PROFIBUS DP (IM 151-1, available in 6 types) or PROFINET (IM 151-3, available in 4 types) bus and handles all data exchanges with the upper-level controller.

Models supporting PROFIBUS are as follows:

• IM151-1 Basic Model (RS485)

• IM151-1 Compact 32DI DC24V (RS485)

• IM151-1 Compact 16DI DC24V / 16DO DC24V/0, (RS485)

• IM151-1 Standard Model (RS485)

• IM151-1 Standard Type (FO)

• IM151-1 High-Performance Model (RS485)

Models supporting PROFINET are as follows:

• IM151-3 Standard Type (RJ45)

• IM151-3 High-Performance Type (RJ45)

• IM151-3 High-Speed Type (RJ45)

• IM151-3 PN (FO)

These interface modules can all be directly mounted on standard tracks.

ATIC ET 200S Compact



The IM 151-1 Compact can be used as a block I/O. Its functionality is based on the IM 151-1 Basic model, combining the interface module with a 32-channel I/O in a single module. The Compact version comes in two types: one with 32-channel switch input and the other with a mixed module featuring 16-channel switch input and 16-channel switch output.The ET 200S compact can be expanded with 12 modules, totaling 128 channels. It can also be paired with modules such as motor starters, inverters, and pneumatic modules, among others.If an 8-channel module is used for expansion, it can achieve a high channel density, thus allowing for more components to be installed within the control box or reducing the size of the control box.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery Shanghai3dayswithin
Stock 90TaiMOQ1Tai
Brand Siemens
Product Line IM 155-6
Export Control Regulations AL: N / ECCN: 9N9999
Measurement of Packaging Dimensions Unit CM
Expiry Long Valid
Update 2023-09-11 10:01
Gallery

Shanghai Zhongheng Kelian Automation Equipment Co., Ltd.Published bySiemens ET200SP Interface ModuleGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top