DTA-500C Differential Thermal Analyzer (Room Temperature to 500°C)

平台认证
  • Unit Price

    Negotiable

  • Brand

    No content provided.

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



上海研锦科学仪器有限公司

VIP   采商通第1年
资料通过中商114认证
  • 孙经理 (Mr.)  

Product Details

Specs

Gallery

  • Brand:

    No content provided.

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0Tai

  • Address:

    All Cities

  • Delivery:

    0Hours

  • View More

Description

Overview

Internally equipped with high-sensitivity differential thermal sensors imported from abroad, offering higher precision and the ability to measure weak signals. Particularly suitable for analysis applications of materials like nylon, polyester, and PET. Differential Scanning Calorimetry (DSC) is a classic thermal analysis method for studying thermal effects under controlled temperature programs and has been widely applied in various fields such as research and development of materials and chemicals, process optimization, quality inspection, and failure analysis. Using DSC methods, we can investigate phase transitions of inorganic materials, melting and crystallization processes of polymer materials, polymorphism of drugs, solid/liquid phase ratios of foods like oils, and more. Compliant with national standards GB/T2951.42-2008, GB/T15065-2009, GB/T17391-1998, and GB/T19466.6-2009.


Technical Features

1. Industrial-grade wide-screen touch structure with rich display information, including set temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, and various switch states.

2. USB communication interface with high versatility, reliable signal without interruption, and supports auto-recovery connection function.

3. The furnace body features a compact structure with adjustable heating and cooling rates.

4. Enhanced installation process with full mechanical fixation, completely eliminating the contamination of the furnace internal gel on the differential thermal signal.

5. Dual-temperature probe ensures high repeatability in sample temperature measurement.

6. The digital gas mass flow meter automatically switches between two gas flow paths, with fast switching speed and short stabilization time.

7. Standard specification samples are provided for customer convenience in temperature coefficient calibration.

8. Software adapts to various computer screen resolutions; supports laptops, desktops, and compatible with operating systems such as WIN2000, XP, WIN7, WIN8, WIN10, etc.

9. Equipped with a high-sensitivity imported differential thermal sensor, offering higher precision and capable of measuring weak signals.

10. Supports user-customizable programming for full automation of measurement steps. The software offers dozens of commands, allowing users to flexibly combine instructions based on their own measurement procedures and save them. Complex operations are simplified into one-touch operation.

11. Optional refrigeration module (suitable for materials with low glass transition or melting points, or for rapid cooling requirements).


Technical Specifications

1. DSC Range: 0 ~ ±250 mW

2. Temperature Range: Room Temperature to 500℃

3. Heating Rate: 0.1~80℃/min

4. Temperature Resolution: 0.01℃

5. Temperature Accuracy: ±0.1℃

6. Temperature Repeatability: ±0.1℃

7. DSC Accuracy: ±1.5%

8. DSC Resolution: 0.001 mW

9. DSC Resolution: 0.001mW

10. Temperature Control Methods: Heating, Constant Temperature, Cooling, and Circulating Temperature Control (fully automatic program control)

11. Curve Scanning: Heating Scan

12. Atmosphere Control: The gas quality flow meter automatically switches between two gas lines

13. Display Method: 24-bit color, 7-inch LED touch screen display

14. Data Interface: USB standard interface, with corresponding operation software

15. Parameter Standards: Equipped with standard calibration materials, featuring a one-button calibration function, allowing users to calibrate temperature independently.

16. Working Power: AC220V 50/60Hz


Application Examples

Measure physical and chemical changes related to heat, such as glass transition temperature, melting point. Melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/cross-linking, oxidation induction time, reaction kinetics, specific heat, etc.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery All Cities
Brand No content provided.
Manufacturer Direct Sale
Supply Volume 999
Support Customized
Expiry Long Valid
Update 2025-11-16 15:51
Gallery

Shanghai Yanjin Scientific Instruments Co., Ltd.Published byDTA-500C Differential Thermal Analyzer (Room Temperature to 500°C)Gallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top