Overview
China's first dedicated oxidation induction time tester, featuring a 10.1-inch Android industrial control computer, no computer connection required, one-touch operation for testing oxidation induction time and melting point, automatically generates oxidation induction time maps, and can connect to a printer for report maps. The instrument beeps after the automatic oxidation induction time operation ends, no personnel supervision needed during the process, simple and efficient. Compliant with national standards GB/T2951.42-2008, GB/T15065-2009, GB/T17391-1998, GB/T19466-2009, IEC60811-4-2:2004, GB/T19466.6-2009.
Technical Features
1. 10.1-inch industrial-grade wide-screen touch structure, displaying comprehensive information including set temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, and various switch states.
2. Directly connect the printer to print report graphs and traceability reports.
3. The furnace body features a compact structure with adjustable heating and cooling rates.
4. Enhanced installation process with full mechanical fixation, completely avoiding the contamination of the heat differential signal by the internal gel of the furnace.
5. Dual temperature probes ensure high repeatability in sample temperature measurement.
6. The digital gas mass flow meter automatically switches between two gas flow paths, with quick switching speed and short stabilization time.
7. Standard with automatic temperature calibration feature included.
8. Integrated industrial control computer; no need to connect to a PC, directly test the oxidation induction time and melting point.
9. Export the oxidation induction time test charts and melting point test charts via a USB flash drive.
10. Software for PC is adaptable to various resolution computer screens; supports laptops, desktops, and is compatible with operating systems such as WIN2000, XP, WIN7, WIN8, WIN10, etc.
11. Can be set up with three-tier accounts, featuring traceability records and search capabilities.
Technical Specifications
DSC Range: 0 ~ ±250 mW / 0 ~ ±500 mW
2. Temperature Range: Room Temperature to 500℃
3. Heating Rate: 0.1~80℃/min
4. Temperature Resolution: 0.01℃
5. Temperature Fluctuation: ±0.1℃
6. Temperature Repeatability: ±0.1℃
7. DSC Noise: 0.001 mW
8. DSC Resolution: 0.001mW
9. DSC Accuracy: ±2%
10. DSC Sensitivity: 0.001 mW
11. Temperature Control Methods: Heating, Constant Temperature, Cooling, Circulation (Full Automatic Program Control)
12. Curved Scan: Temperature Rise Scan
13. Atmosphere Control: Automatic switching of nitrogen and oxygen gas mass flowmeters
14. Display Method: 24-bit color, 10.1-inch LCD touchscreen display
15. Data Interface: Standard USB Port, RS232
16. Parameter Standard: Equipped with standard substances, one-touch temperature calibration
Application Examples
Specifically designed for measuring the oxidation induction period in the plastic, rubber, and cable industries.