Shenzhen ZhongNuo Testing Technology Co., Ltd. specializes in explosion-proof CCC certification consulting services, boasting an extensive portfolio of consulting cases in this field. We are well-versed in the application process and technical requirements for explosion-proof 3C certification, offering services such as application assistance and factory audit guidance for clients.
What products can apply for the intrinsically safe explosion-proof certification? What are the requirements?
"Ben-Air is one type of explosion-proof protection, which limits electrical energy so that equipment remains safe even in the event of a malfunction."
A type of explosion-proof protection that the energy produced is not sufficient to ignite the surrounding explosive environment.
Therefore, intrinsic safety requirements for electrical equipment include limitations on current, voltage, capacitance, inductance, etc., making them suitable only for low-power devices.
Additionally, there are specific requirements for the power supply method of intrinsically safe equipment, plastic enclosures, and wireless transmission.
The product application for intrinsic safety certification requires the submission of the product's schematic, PCB diagram, etc.
ZhongNuo Inspection has dedicated engineers specializing in intrinsic safety circuit and structural design.
We offer technical consultation services for explosion-proof circuit design, drafting, and modification. We have extensive experience in designing and obtaining certifications for intrinsic safety levels ia, ib, and ic.
If you require certifications in this field, welcome to DM Shenzhen ZhongNuo Testing Technology Co., Ltd.!
Electrical equipment used in explosive gas environments, applying for the explosion-proof CCC certification standards
Ex-proof Type: Intrinsically Safe
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.4-2021 Explosive Atmospheres, Part 4: Equipment protected by intrinsic safety "i"
Exlosion-proof Type: Intrinsic Safety Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 3836.2-2021 Explosive Atmospheres – Part 2: Equipment protected by explosion-proof enclosures “d”
Ex-proof Type: Increased Safety Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 36.3-2021 Explosive Atmospheres Part 3: Equipment protected by intrinsic safety "i"
Exlosion-proof Type: Positive Pressure Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.5-2021 Explosive Atmospheres, Part 5: Equipment protected by positive pressure housing "p"
Explosion-proof Type: Immersed Oil Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.6-2017 Part 6: Equipment protected by liquid immersion type “o” for explosive environments
Exlosion-proof Type: Sand-filled Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres – Part 1: Equipment – General Requirements
GB/T 3836.7-2017 Electrical Equipment for Explosive Gas Atmospheres – Part 7: Sand-filled Type “q”
Explosion-proof Type: "N" Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.8-2021 Explosive Atmospheres Part 8: Equipment protected by "n" type of protection
Explosion-proof Type: Encapsulation Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 3836.9-2021 Explosive Atmospheres, Part 9: Equipment protected by "m" type encapsulation
Electrical Equipment for Use in Explosive Dust Environments - Application Standards for防爆CCC Certification
Explosion-proof Type: Intrinsically Safe
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 3836.4-2021 Explosive Atmospheres, Part 4: Equipment protected by intrinsic safety "i"
Exlosion-proof Type: Dust Ignition-Proof Enclosure
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.31-2021 Explosive Atmospheres, Part 31: Equipment protected by dust-protection enclosures "t"
Ex-proof Type: Cast Molding
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.9-2021 Explosive Atmospheres, Part 9: Equipment protected by "m" type encapsulation
Exlosion-proof Type: Positive Pressure Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.5-2021 Explosive Atmospheres, Part 5: Equipment protected by positive pressure enclosures "p"
What is the relationship between the explosion-proof certificate and the explosion-proof CCC certification?
Which certification is required for a company's explosion-proof products to enter the market? What are the requirements for the applying company, etc.? These are many of the current dilemmas faced by enterprises.
Below, ZhongNuo Inspection simplifies it for everyone's understanding.
Firstly, explosion-proof certificates and the explosion-proof CCC certification are both certification requirements for explosion-proof equipment.
Whether to apply for a防爆 certificate or防爆CCC certification largely depends on the product category.
Put simply, it's to check if your product is listed in the防爆CCC certification product catalog.
Yes, obtain the explosion-proof CCC certification; no, obtain the explosion-proof compliance certificate.
Explosion-proof 3C Certification Consultation Services - Shenzhen ZhongNuo Testing Technology Co., Ltd.