Combustible Gas Alarm Calibrator

平台认证
  • Unit Price

    $1000.00/A

  • Brand

    ZhongNuo Inspection

  • MOQ

    1A

Contact
Leave Msg

Platform Service

Supplier Verified



深圳中诺检测技术有限公司

VIP   数字营销第2年
资料通过中商114认证
Recommend

Product Details

Specs

Gallery

  • Brand:

    ZhongNuo Inspection

  • Unit Price:

    $1000.00 / A

  • MOQ:

    MOQ1A

  • Total:

    9999A

  • Address:

    GuangdongShenzhen

  • Delivery:

    3days

  • View More

Description

Shenzhen ZhongNuo Inspection Technology Co., Ltd. specializes in the calibration, verification, and measurement services for equipment such as gas alarms, flammable gas detectors, and harmful gas detection instruments for various locations. We hold qualifications to serve nationwide, addressing clients' electrical safety and explosion-proof fire prevention concerns, and contributing to safe production.
The calibration cycle for flammable gas detectors is typically once a year.
In accordance with the standard JJG 693-2011 "Flammable Gas Detectors," the calibration interval for flammable gas detectors generally does not exceed one year. This means that under normal circumstances, a comprehensive calibration and testing of flammable gas detectors should be conducted annually to ensure their performance meets relevant requirements.
可燃气体报警器校准机构
Gas Detector Alarms Calibration Specification Requirements
Regulation 5.5 of the "Regulation for Calibration of Combustible Gas Detectors" (JJG693-2011) stipulates: The calibration cycle for combustible gas detection and alarm instruments: Generally, the calibration cycle of the instrument shall not exceed one year. If there is any doubt about the measurement data of the instrument, or if the instrument has been replaced with major components or repaired, it should be sent for calibration promptly.
Section 3.5 of the "Regulations for the Use of Combustible Gas Detection and Alarm Systems" (SY6503-2000) stipulates: Combustible gas detection and alarm systems in use shall be calibrated regularly as per the regulations.
Occupational Health Service - Technical Specifications for the Setting of Toxic Gas Facilities (GBZ/T223-2009), Article 7.2.1 stipulates: Calibration of detection and alarm devices shall be performed regularly according to the manufacturer's specified time and procedures.
Section 3.4 of the "Regulations for the Use of Flammable Gas Detectors and Alarms" (SY6503-2000) stipulates: The flammable gas detectors and alarms installed and used shall have measurement instruments manufactured by an institution recognized for their**measurement accuracy** and**explosion-proof performance**.
可燃气体报警器校准机构
What are the contents included in the calibration report for flammable gas detectors?
The verification results should be reflected in the verification certificate or report, and the verification proof or report must include the following information.
① Title, such as "Calibration Certificate" or "Calibration Report";
② Laboratory Name and Address
③ Calibration Location (if not calibrated in the laboratory)
④ Standby letter of credit or report (e.g., numbered), with page numbers indicated on each page
5. Shipper's name and address
⑥ Describe and clearly identify the target school.
Calibration date and receipt date;
⑧ Technical specifications for calibration base, including name and code;
Description of the traceability and validity of the measurement standards used for calibration.
⑩ Description of Calibration Environment
11. Calibration Results and Measurement Uncertainty Statement
12. Signature, title or equivalent symbol, and issuance date of the certifier or issuer of the calibration certificate or calibration report.
13. Calibration results are only applicable to the calibration object.
14. No part of the certificate or report may be copied without written approval from the laboratory.
Two reproofing time intervals
Instrument recalibration is typically every 1 year, determined by the submitting unit based on actual usage. During the secondary calibration process, if there are doubts about the instrument's test data, or if the main components of the instrument are replaced, or if recalibration is needed after repairs.
可燃气体报警器校准机构
Standard for calibration and verification of flammable and toxic gas detectors:
GB/T 50493-2019 "Design Standard for Detection and Alarm Systems of Combustible and Toxic Gases in Petroleum and Chemical Industries"
GB12358-2006 General Technical Requirements for Environmental Gas Detection and Alarm Instruments in Workplace
JJG693-2011 "Regulation for Calibration of Combustible Gas Detectors"
Shenzhen Zhongnuo Testing Technology Co., Ltd. is a third-party institution specializing in electrical safety, electrical explosion-proofing, gas alarms, and toxic gas detection instruments for regular inspections, metrological measurements, and calibrations. We provide资质 services to address fire and explosion prevention issues for our clients.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1000.00 / A
Sales None
Delivery GuangdongShenzhen3dayswithin
Stock 9999AMOQ1A
Brand ZhongNuo Inspection
Testing Method On-site inspection
Inspection Cycle Annual inspection every 1 year
Report CMA and CNAS
Expiry Long Valid
Update 2025-11-10 11:18
Gallery

Shenzhen Zhongnuo Inspection Technology Co., Ltd.Published byCombustible Gas Alarm CalibratorGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top