Offer SIL Certification and SIL Grading Consultancy Services – Shenzhen Zhongnuo Testing Technology Co., Ltd.
SIL functional safety certification is applicable to all equipment used to implement process control safety functions, mainly divided into electrical components and safety systems categories.
1. Electrical Components: Actuators, solenoid valves, field sensors, pressure transmitters, temperature transmitters, level transmitters, level switches, programmable controllers, logic solvers, field safety actuators (pneumatic/liquid/pneumatic), safety switches, safety valves, cutoff valves, solenoid valves, safety interlocks, etc.
2. Safety Systems: SIS (Safety Instrumented System), ESD (Emergency Shutdown System), Instrument Protection System (IPS), Burner Management System (BMS), F&G (Fire and Gas Protection System), HIPPS (High-Pressure Pipeline Protection System), PSD (Process Shutdown System).
3. Other: Electronics/Electrical/Programmable electronic products with safety requirements.
SIL certification, also known as Functional Safety Certification, focuses on the safety functions of a product. Obtaining SIL certification is to verify whether these safety functions can be reliably and safely implemented.
For instance, with a lighting fixture, we're concerned with its lighting function, whether its light intensity can reliably and safely meet our requirements.
Safety Integrity Level, abbreviated as SIL, is differentiated by the probability of hazardous failure occurring per hour.
There are four SIL levels specified in the international IEC standards, with SIL4 indicating a high degree of integrity and SIL1 representing a low level. For each safety integrity level, specific design specifications are established to reduce design errors.
The safety level required for the production process is assessed and determined by a specialized production technology company. Generally, for production processes with higher safety requirements, the required safety level is SIL3.
As the recognition of industrial accidents and their impact on society becomes widespread, more and more companies are realizing the importance of safety.
In modern process industries, due to the complexity of processes and the multitude of equipment, any failure can have severe consequences for employees, the public, equipment, or the environment.
The SIL certification process involves helping businesses fully leverage their proven engineering practices and safety technologies (IEC61508 and IEC61511) to prevent industrial accidents from recurring. This is because these experiences and technologies are based on extensive practical experience and lessons learned.
With the issuance of the IEC 61508 and IEC 61511 series standards, a systematic functional safety assessment and testing process can effectively address this issue.
SIL certification is a third-party assessment, verification, and certification process based on standards such as IEC 61508 (GB/T 20438), IEC 61511 (GB/T 21109), IEC 61513, IEC 13849-1, IEC 62061, and IEC 61800-5-2, which evaluate and confirm the Safety Integrity Level (SIL) or Performance Level (PL) of safety equipment. Functional safety certification primarily involves assessments of document management (FSM) for the development process of safety equipment, hardware reliability calculations and evaluations, software evaluations, environmental testing, and EMC electromagnetic compatibility testing. SIL certification is divided into four levels: SIL1, SIL2, SIL3, and SIL4, covering both product and system levels, with SIL4 being the most stringent.