Computer cables are a type of electrical equipment cable, suitable for electronic computers and automatic instruments with high requirements for interference resistance at rated voltages of 500V or less. Depending on different environmental and equipment usage requirements, the cable insulation can be made of materials such as polyethylene, polyvinyl chloride, cross-linked polyethylene, fluoroplastic, and silicone rubber.
The individual pairs of shielded twisted pairs should not be disconnected from each other, nor should they be disconnected from the overall shield.
The cores of the cables and between the cores and the shielding or other metal layers should withstand 50Hz, alternating voltage of 2000V for 1 minute or 1500V for 5 minutes without breakdown.
High insulation resistance, good voltage resistance, small dielectric constant, and minimal temperature and frequency dependence of dielectric loss in polyethylene not only meet the transmission performance requirements but also ensure the cable's service life.
To minimize mutual interference between circuits and external disturbances, the cable must be constructed with a shielding structure. Shielding materials include tin-plated or untinned copper wire, copper strip, copper-plastic composite tape, and aluminum-plastic composite tape, among others. The metallic strips are produced by wrapping, with an overlap rate typically not less than 15%, but specific standards may have special provisions; for instance, TICW/06 specifies that the overlap rate of the shielding metallic strip should not be less than 25%. The metallic wire is produced by weaving, with a weaving coverage rate not less than 80%, and may not be less than 90% if higher anti-interference requirements are needed.
The shielding requirements for cables are adopted separately for different scenarios: segmented shielding (only for twisted pairs, with each twisted pair having its own shielding), overall shielding (the cable has only one overall shielding layer after the core is stranded), and segmented + overall shielding (combining both of the above structures). To meet higher requirements from users and usage scenarios, the overall shielding structure can be implemented using a composite shielding method, which includes two layers of shielding, consisting of metal tape wrapping and metal wire braiding.
Note: If the cable has a segmented shielding structure, the shielding layers should have good insulation properties, and polyester tape or other non-absorbent wrapping tape should be applied on the outer side of the segmented shielding.
Name Edit Voice
DJYPV
Polyethylene-insulated twisted copper wire braid with PVC sheath
Electrical Cable Sleeves
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP
PVC-jacketed braided shielded copper twisted pair with polyethylene insulation
Electrical Cable Sleeves Count
Lay indoor, cable trench, pipeline, etc., requiring electrostatic shielding
Occasion
DJYPVP
Polyethylene insulated twisted copper wire, braid shielded and overall shielded
Chlorinated Polyvinyl Chloride (PVC) Jacketed Computer Cable
Install indoor, cable trench, pipeline, etc., requiring electrostatic shielding
Occasion
DJYP2V
PVC jacketed twisted copper strips with polyethylene insulation
Electrical Cable
Lay indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYVP2
Polyethylene insulated twisted copper strip with overall shielding and polyvinyl chloride sheath
Electrical Cable
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYP2VP2
Polyethylene insulated twisted copper strips, individually shielded and overall shielded polyvinyl chloride
Enveloped computer cable
Lay indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYP3V
Polyethylene insulated twisted aluminum-plastic composite tape, shielded with polyvinyl chloride
Computer Cable Jacket
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYVP3
Polyethylene insulated twisted aluminum-plastic composite tape, overall shielded with polyvinyl chloride
Computer cable sleeve
Install indoor, cable trench, pipeline, etc., requiring static shielding
Occasion
DJYP3VP3
Polyethylene insulated twisted aluminum-plastic composite tape with both individual shielding and overall shielding
PVC sheathed computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Event
DJYPVR
PVC-jacketed braided copper twisted pair with polyethylene insulation
Computer cable sleeve
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYVPR
Polyethylene insulated twisted copper wire braid overall shielded with PVC sheath
Computer cable sleeve
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYPVPR
Polyethylene insulated twisted copper wire with braided and overall shielding
Chlorinated Polyvinyl Chloride (PVC) Jacketed Soft Computer Cable
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Occasion
DJYP2VR
Polyethylene insulated paired copper strip, sheathed with PVC (PVC insulated) for flexible cables
Computer Cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYVP2R
Polyethylene insulated twisted copper tape, overall shielded with PVC sheath, flexible
Computer Cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYP2VP2R
Polyethylene insulated twisted copper strip, individually shielded and overall shielded polyvinyl chloride
Thermally protected soft computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYP3VR
Polyethylene-insulated twisted aluminum-plastic composite tape, shielded with polyvinyl chloride
Computer cable jacket
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYVP3R
Polyethylene-insulated, twisted pair, aluminum-plastic composite tape, overall polyvinyl chloride shielding
Computer Cable Jacket Soft
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Occasion
DJYP3VP3R
Polyethylene insulated twisted aluminum-plastic composite tape, with both shielded and total shielded versions
PVC Sheathed Soft Computer Cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Occasion
DJYPV22
PVC-jacketed braided shielded copper wire with polyethylene insulation
Steel-braided computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical external force fixation sites and withstand
DJYVP22
Polyethylene insulated twisted copper wire braid overall shielded with PVC sheath
Steel-braided armored computer cable
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Large mechanical external force fixed sites and withstand
DJYPVP22
Polyethylene insulated twisted copper wire with braided and overall shielding
Chlorinated polyvinyl chloride sheathed steel tape armored computer cable
Install indoor, cable trench, pipeline, etc., requiring electrostatic shielding
Large mechanical external force fixation sites and withstand
DJYP2V22
Polyethylene insulated twisted copper strip, shielded with PVC sheath and steel
Computer cable with armor
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical force fixed sites and withstand
DJYVP2-22
Polyethylene insulated twisted copper tape, overall shielded with PVC jacket, steel
Computer cable with armor
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Large mechanical external force fixed sites and withstand
DJYP2VP2-22
Polyethylene insulated twisted copper tape, both individually shielded and overall shielded polyvinyl chloride
Polyethylene sheath steel tape armored computer cable
Install indoor, cable trenches, pipelines, etc., with static shielding requirements
Large mechanical force fixed fields and withstand
DJYP3V22
Polyethylene insulated twisted aluminum-plastic composite tape with shielding polyvinyl chloride
Computer Cable with Steel Tape Armor
Install indoor, cable trench, pipeline, etc., with static shielding requirements
Large mechanical external force fixed sites and withstand
DJYVP3-22
Polyethylene insulated twisted aluminum-plastic composite tape, overall PVC shielding
Sheathed steel tape armored computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large machinery with external force fixation and bearing capacity
DJYP3VP3-22
Polyethylene insulated twisted aluminum-plastic composite tape, shielded and total shielded
PVC jacketed steel tape armored computer cable
Install static shielding for indoor environments, cable trenches, pipelines, etc.
Large mechanical external force fixation sites and withstand