1. Fiber Optic CableCross-sectional illustration

2. Label
2.1 Fiber Chromatography
Serial Number | 1 | 2 | 3 | 4 | 5 | 6 |
Color | Blue | Orange | Green | Brown | Gray | Please provide the Chinese content you would like translated into American English. |
2.2 Pipe sleeveChromatography
Serial Number | 1 | 2 | 3 | 4 |
Color | Blue | Orange | Green | Brown |
3. Fiber Optic Cable Structure Dimensions
Fiber optic core count | / | 24 | |
Structure | / | 1+5 | |
Fiber Type | / | G.652D | |
Central | Material | mm | Phosphated steel wire |
Reinforcement part | Dimensions | 1.35 | |
Loose-tube assembly | Material | PBT | |
Diameter | mm | 1.65±0.05 | |
Wall thickness | 0.25±0.05 | ||
Each tube's large core count | 6 | ||
Waterproofing layer | Materials | / | Cable grease |
Armored layer | Materials | mm | Coated Steel Strip |
Inner sleeve | Material | mm | Medium Density Polyethylene (MDPE) |
InsideProtective thickness | 1.2±0.1 | ||
Outer sheath | Material | mm | PVC |
Outer Shell Thickness | 1.0±0.1 | ||
Color | Blue | ||
Fiber Optic Cable Diameter | mm | 9.5±0.5 | |
4. Optical Performance
Fiber Optic Technical Parameters(ITU-T Rec. G.652D)
Fiber Optic Characteristics | Unit | Numeric | |
1.Geometry Features | 1.1 Coating Diameter | um | 125±1.0 |
1.2 Chip/Tolerance of concentricity deviation | um | ≦0.6 | |
1.3 Coating non-roundness | % | ≦1.0 | |
1.4 Outer Coating Diameter | um | 242±7 | |
1.5 Outer Coating/Coating concentricity deviation | um | ≦12 | |
2.Attenuation Features | 2.1 1310nm OTDRDecay | dB/km | ≦0.36 |
2.2 1550nm OTDRAttenuation | dB/km | ≦0.22 | |
3.Model Field Diameter | 3.1 1310nmModular Field Diameter | um | 9.2±0.4 |
3.2 1550nmMold diameter | um | 10.4±0.5 | |
5. Physical Properties
5.1 Optical Cable Bend Radius: 12.5 Optical Cable Diameter(Static)
25 Optical Cable Diameter(Dynamic)
5.2 Cable application temperature range
Operating Temperature | : -40oC to +60oC |
Storage,Transportation Temperature | : -40oC to +70oC |
Installation Temperature | : -20oC to +60oC |
5.3Key mechanical and environmental performance tests
Serial Number | Project | Testing Method | Acceptance Requirements |
1 | Stretched IEC 60794-1-2-E1 | - Load: 600 N(LongDue date) 1500 N(Short-term) - Tested Length: 50 Rice - Load Duration: ≥1Minute | Long-term tension load: - Fiber optic cable shows no significant strain - No significant additional attenuation Short-term tension load: - Fiber Optic Strain: £ 0.4% - Additional Attenuation: £ 0.1dB After testing is completed: - No apparent residual additional attenuation - No visible residual fiber strain - No fiber breaks and visible sheath cracks - Fiber optic residual strain: £ 0.08% |
2 | Flatten IEC 60794-1-2-E3 | - Load: 1000 N (Long-term) 3000 N (Short-term) - Load Duration: ≥1Minute | Long-term flattened load: - No significant additional attenuation Under short-term compression loading: - Additional Attenuation: £ 0.1dB After testing is completed: - No significant residual additional attenuation - No fiber breaks and visible sheath cracks |
3 | Impact IEC 60794-1-E4 | - Impact Points: 5dot - Each point impact frequency:1Next - Impact Energy:10 N·m | After testing is completed: - No significant residual additional attenuation - No fiber breaks and no visible crack in the sheath |
4 | Repetitive bending IEC 60794-1-2-E6 | - Core shaft radius: 25 Optical Cable Diameter - Load: 25kg - Tested Length: 1Rice - Bend Rate: 2 Second/Next - Bend cycles: ≥30Next - Bend Angle: ±90° | After testing is completed: - No significant residual additional attenuation - No fiber breaks and visible sheath cracks |
5 | Twist IEC 60794-1-E7 | - Tested Length: 1 Rice - Load: 25kg - Twist Angle: ±90° - Twist cycles: ≥10Next | After testing is completed: - No apparent residual additional attenuation - No fiber breaks and no visible cracks in the sheath |
6 | Water Permeability Test IEC 60794-1-F5B | - Water Column Height: 1Rice - Sample Length: 3Rice - Test Time: 24hour | - No leakage |
6. Platter Packaging and Labeling
6.1 Packaging
6.1.1 Optical Cable for ExportMulti-layer boardPlatter/Ironwood tray packaging
6.1.2 Standard Serving Length:2000m/3000m/4000m2% 0
6.2 Label
6.2.1 Dishware Label Content
- Manufacturer's Name &LOGO;
- Arrow indicating correct scrolling direction;
- Arrow indicating the location of the cable's outer end;
- Proper Handling and Placement of Fiber Optic Cables Sign;
- Other customer required identification content
6.2.2 Signage
- Product Name;
- Fiber Optic Cable Models and Specifications;
- Plating Length;
- Gross Weight,Net Weight;
- Lot Number;
- Manufacturer's Name;
- Manufacturing Date and Month;
- Other identification content required by customers
6.3 Cable Quality Assurance Documentation
- Test Report