Description

Railway signal cables are suitable for transmitting railway signals, audio signals, or automatic signal devices at rated voltages of AC 500V or DC 1000V and below.

Control circuit, where the integrated sheath railway signal cable has certain shielding properties, suitable for electrified sections or other areas with strong electromagnetic interference.

Installation in areas prone to electrical interference.

1. Features of Use

1.1 The cable is suitable for use in an environmental temperature range of -40℃ to +60℃.

1.2 The long-term working temperature of the cable conductor should not exceed +70°C.

1.3 Cable Laying Environmental Temperature: The polyvinyl chloride (PVC) outer sheath cable should not be lower than 0℃; the polyethylene (PE) outer sheath cable should not be lower than -20℃.

1.4 Allowable Bend Radius for Cable: Non-armored cables should not be less than 10 times the cable's outer diameter; armored cables should not be less than 15 times the cable's outer diameter.

1.5 The ideal shielding coefficient for the comprehensive sheath railway signal cable is ≤0.8; the ideal shielding coefficient for the aluminum sheath railway signal cable is ≤0.3.

2 Model, Name and Specifications

Model Name Laying Range Specifications (Cores)

PTYV polyethylene insulated PVC sheathed railway signal cables, laid in soil, trenches, or pipes, can withstand general mechanical stresses. Recommended cores: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYY Insulated Polyethylene Sheathed Railway Signal Cables are recommended for cores of 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C * 1.0mm

PTY22 polyethylene insulated steel tape armored polyvinyl chloride sheathed railway signal cables laid in soil, trenches, or pipes can withstand considerable mechanical external forces. Recommended for cores of 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm.

PTY23 Polyethylene insulated steel tape armored polyethylene sheathed railway signal cables are recommended for cores of 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYA22 polyethylene insulated comprehensive sheath steel tape armor PVC outer sheath railway signal cable, recommended core counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYA23 Polyethylene Insulated Comprehensive Sheath Steel Tape Armored Polyethylene Outer Sheath Railway Signal Cable, recommended core counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYL23, Aluminum sheathed railway signal cable. Recommended core counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

PTYA polyethylene insulated composite sheath polyethylene outer sheath railway signal cables, recommended core counts: 4, 6, 8, 9, 12, 14, 16, 19, 21, 24, 28, 30, 33, 37, 42, 44, 48, 52, 56, 61C cores * 1.0mm

Plastic insulated and PVC sheathed railway signal cables, includingPTYAH, PTYAP, PZYAP, PTYV, PTYY, PTY22, PTY23 (PZY02, PZY03, PZY23, PZY22), with 1/0.8mm (1/1.0mm) conductor size, 2-48 cores, suitable for railway signal communication, fire alarm signals, telegrams, and other automatic system applications, rated for AC 500V or DC 1000V and below.

Polyethylene insulated composite sheath steel tape armored polyvinyl chloride sheath railway signaling cable

PTYA23, PTYA22, PTY23, PTY22, PTYAH23, PZYA23, PZYA22, PZY23, PZY22, 20.8mm (1/1.0mm) 4-61 cores, suitable for transmission of audio signals and control lines for fixed railway signaling and group automation assembly at AC rated voltage 500V or DC voltage 1000V and below. It can transmit general automatic signals for railway groups and also frequency-modulated automatic block signals and business communication audio signals.

  

Our company specializes in the production of mining communication cables, control cables, signal cables, communication cables for coal mines, explosion-proof telephony lines, explosion-proof communication cables, control cables for coal mines, signal cables for coal mines, communication cables for mining, telephony cables for mining, telephone lines for mining, flame-retardant communication cables for mining, flame-retardant signal cables for mining, flame-retardant control cables for mining, communication cables for mine shafts, signal cables for mine shafts, control cables for mine shafts, monitoring cables for mining, surveillance cables for mining, telemetry cables for mining, monitoring lines for mining, surveillance lines for mining, telephony cables for mining, explosion-proof cables for mining, mining cables, flame-retardant cables for mining, sensor cables, MHYV, MHYAV, MHYA32 mining communication cables, MHYV, MHYVR, MHYVP, MHYVRP, MHY32 mining signal cables (communication cables for mining), MKVV, MKVV22, MKVV32, MKVVR mining control cable products, all with the "Coal Safety Mark" certificate, offering a complete range of specifications. The products are widely used in major coal mine systems and monitoring systems, sold across all regions to coal companies and mining groups. They have also become配套 products for several mining equipment companies, establishing long-term cooperative relationships and consistently receiving positive feedback and trust from customers!

We also manufacture plastic insulated indoor communication cables, telephone cables, large pair-count communication cables, computer cables, and power cables for communication equipment; railway signaling cables. We have all the necessary authoritative certificates, ensuring reliable quality!!


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HebeiLangfang
Brand Tianlian Cables
After-sales Service Comprehensive after-sales service
Operating Temperature No higher than +70°C
Operating Environment Temperature -40°C to +60°C
Expiry Long Valid
Update 2025-03-27 08:56
Gallery

Tianjin Cable Works, First BranchPublished byRail Signal CableGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top