Description of Clock IC DS1302ZN:
The DS1302 slow-charging real-time clock (RTC) chip includes a real-time clock/calendar and 31 bytes of non-volatile static RAM. It communicates with a microprocessor via a simple serial interface. The real-time clock/calendar can count seconds, minutes, hours, days, weeks, months, and years. It automatically adjusts the end-of-the-month date for months with fewer than 31 days and features leap year correction. The clock can be in 24-hour format or a 12-hour format with AM (morning) or PM (afternoon). The 31-byte RAM can be used to temporarily store important data. Synchronous serial communication simplifies the communication between the DS1302 and the microprocessor. Communication with the clock/RAM requires only 3 lines: (1) RST (reset), (2) I/O (data line), and (3) SCLK (serial clock). Data can be transmitted in single-byte form, up to 31 bytes in multi-byte form. The DS1302 operates at very low power consumption, requiring less than 1µW to save data and clock information.
Clock IC DS1302ZN Features:
Countable in seconds, minutes, hours, days, weeks, months, and years with leap year compensation
31-byte non-volatile RAM for high-speed data caching
Wide operating voltage range: 2~5.5V
2.5V power consumption less than 300nA
Single-byte or multi-byte data transmission method for clock or RAM data read/write
Simple 3-wire interface for communication with the microcontroller
TTL Compatible (VCC=5V)
Optional industrial temperature range: -40℃ to +85℃
Packaging: DIP8 and SOP8
Clock IC DS1302ZN Application Areas:
Portable Instrument
Mobile Phone
Reactive Rate Energy Meters, IC Card Water Meters, IC Card Gas Meters
Fax Machine
The maximum specifications for the clock IC DS1302ZN:
| Parameter Name | Symbol | Numeric | Unit |
| Pin-to-ground voltage | VP | -0.5~+7 | V |
| Operating Temperature | TA | 0~70 | ℃ |
| Storage Temperature | TS | -55~+175 | |
| Welding Temperature | TH | 260 (10 seconds) |
DC operating conditions for the clock IC DS1302ZN:
(TA=0℃~70℃)
| Parameter Name | Symbol | Test Conditions | MIN Value | MAX Value | Unit |
| Supply Voltage | VCC1,VCC2 | 2 | 5.5 | V | |
| Logic 1 Input Voltage | VIH | 2 | VCC+0.3 | V | |
| Logic 0 Input Voltage | VIL | VCC=2V | -0.3 | +0.3 | V |
| VCC=5V | -0.3 | +0.8 | V |
Direct Current Characteristics of Clock IC DS1302ZN:
Direct Current Characteristics(0°C to 70°C; VCC=2.5V to 5.5V)

AC Characteristics(TA = 0°C to 70°C; VCC = +5V ±10%)