Coal mine flame-retardant control cable

MKVVCoal mine control cablesMKVVPPlastic control cables for coal minesMKVV22Plastic insulated cables for coal mines |
Standard of Execution: Company StandardQ/TX001-2006 This standard applies to flame-retardant control cables with copper-core polyvinyl chloride sheath for use in coal mines. |
Cable model, name, specifications, and application |
| MKVV Copper-core Polyethylene Insulated PVC Sheathed Flame-retardant Mining Control Cable (2-14)*(4-6)(2-61)*(0.75-2.5) for fixed installations indoors, cable trays, pipelines, etc.
MKVV22 Copper-core Polyethylene Insulated PVC Sheathed Steel Tape Armored Flame-retardant Mining Control Cable (7-61)*(0.75-1.5)(4-14)*(4-6) for fixed installations indoors, cable trays, pipelines, direct burial, capable of withstanding significant mechanical forces.
MKVV32 Copper-core Polyethylene Insulated PVC Sheathed Wire Armored Flame-retardant Mining Control Cable (2-61)*(0.75-2.5)(4-14)*(4-6) for fixed installations indoors, cable trays, pipelines, direct burial, hanging, capable of withstanding significant tensile forces.
MKVVP22 Mining Use Copper-core Polyethylene Insulated PVC Sheathed Braided Shielded Steel Tape Armored Flame-retardant Control Cable (4-14)*(4-6)(4-61)*2.5mm2 for fixed installations in high-magnetic field indoors, cable trays, pipelines, direct burial, hanging, capable of withstanding significant tensile forces.
MKVVRP Mining Use Copper-core Polyethylene Insulated PVC Sheathed Braided Shielded Flame-retardant Control Flexible Cable (4-61)*(0.5-2.5)(4-37)*(1.5-2.5) for fixed installations in high-magnetic field indoors, cable trays, pipelines, etc. MKVVCable,MKVVPCable,MKVVP2Cable,MKVV22Cable,MKVV32Cable,MKVVRCable,MKVVRPCable,MKVVP22Flame-retardant control cables for coal mines, etc., with specifications and models, recommend a cable core number of2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61Chip
MKVV(2-14)*(4-6)mm2 ,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 1Rated Voltage450/750v 2The length of the cable conductor is permitted for operation at temperatures of70Celsius 3The laying temperature of the cables should not be lower than0Celsius, recommended allowable bend radius; 4Unarmored cables should not be less than the outer diameter of the cable.6X2 5Cables with armored or copper braid shielding should be no less than the cable's outer diameter.12Multiple. 6Flexible cables with shielding structures should not be less than the outer diameter of the cable.6Multiple. MT386-1995"Test Methods and Evaluation Rules for Flame Retardant Cables Used in Coal Mines"Q/TX 001-2006 Plastic Insulated Control Cable for Coal Mines |