I. Main Application:
It is primarily used for measurement and detection with high requirements for shielding performance, in fields such as information security and EMC testing. Its main structural features include ease of assembly and disassembly, attractive appearance, and relatively light weight.
II. Performance Specifications:

III. Structural Composition:
1. Housing: Features a six-panel housing with insulation treatment between the housing and the ground. The six-panel housing is constructed from 1.5mm thick cold-rolled steel sheets in modular units, assembled with zinc-plated bolts, nuts, washers, and conductive gaskets after being electroplated and painted.
2. Shield Doors: Configurable shield doors to meet user requirements, including electric (manual) locking shield doors, manual locking shield doors, pneumatic shield doors, and fully automatic shield doors, etc. Custom specifications and sizes available (special double-opening shield doors can be made upon request).
3. Ventilation waveguide windows: Honeycomb ventilation waveguide windows, size 300×300mm. Considering connection with central air conditioning or fresh air systems, various non-standard size waveguide windows can be configured according to the specifications of shielding rooms.
4. High-performance Low-Leakage Power Filters: Capable of handling various specifications of power cables for 220V/380V, 50Hz power supplies, suitable for shielding room equipment; additionally, we can provide customized power filters to deal with special power supplies (such as 110V/36V, 400Hz, etc.).
5. Indoor Electrical: Indoor setup includes distribution boxes, recessed fluorescent lighting panels (testing rooms can only use incandescent bulbs, the specific quantity is determined by the function and corresponding illumination calculation), cable routing, control switches, and outlets (wall-mounted, floor-mounted, or outlet boxes, quantity based on customer requirements).
6. Interior Renovation: Customized finishing treatments for ceilings, walls, and floors according to customer requirements.
7. Additional Services: Air conditioning can be installed in the shielded room per customer request, along with signal processing. Additionally, all cables connected to the equipment racks must be shielded (such as fire alarms, surveillance, audio, and various data lines).