I. Main Application:
It is primarily used for measurement and detection with high shielding performance requirements, as well as in information security and EMC testing fields. Its main structural features include easy assembly and disassembly, attractive appearance, and relatively light weight.
II. Performance Specifications:

Section 3: Structural Composition:
1. Housing: Equipped with a six-panel housing and insulation treatment between the housing and the ground. The six-panel housing is constructed from 1.5mm thick cold-rolled steel sheets in modular units, assembled with zinc-plated bolts, nuts, washers, and conductive pads after being zinc-plated and powder-coated.
2. Shield Doors: Configurable shield doors to meet user requirements, including electric (manual) locking shield doors, manual locking shield doors, pneumatic shield doors, and fully automatic shield doors, etc. Custom specifications and sizes available (special double-open shield doors can be made upon request).
3. Ventilation Waveguide Windows: Honeycomb ventilation waveguide windows, size 300x300mm. Considered for connection with central air conditioning or fresh air systems, waveguide windows of various non-standard sizes can be configured according to the specifications of shielded rooms.
4. High-performance Low-Leakage Power Filters: Capable of handling various specifications of power cables for 220V/380V, 50Hz, suitable for use in shielded rooms; also offers custom power filters for special power requirements (such as 110V/36V, 400Hz, etc.).
5. Indoor Electrical: Indoor layout includes a distribution box, recessed daylight bulb lighting (only incandescent bulbs allowed in test rooms, quantity based on function and corresponding illumination calculation), cable routing, control switches, and outlets (wall-mounted, floor-mounted, or outlet boxes, quantity determined by customer's requirements).
6. Interior Renovation: Decorate the ceiling, walls, and floor according to customer specifications.
7. Additional: Air conditioning can be installed within the shielded room upon customer request, along with signal processing. Furthermore, all cables connected to the amplifiers must undergo shielding treatment (such as fire alarms, surveillance, audio, and various data lines).