KWKL-200The Type Micro Coulomb Sulfur Analyzer employs the micro-coulomb analysis principle and utilizes computer control throughout the analysis process. The sample, whether solid, liquid, or gas, is injected into the pyrolysis tube of the pyrolyzer by an injector. It is then combusted at a specific temperature, converting the reaction products into titratable ions. These ions are carried by the carrier gas into the titration cell, where they consume titrant from the electrolyte. An electrolytic process generates an equivalent amount of titrant, and the electric charge consumed during electrolysis is measured. According to Faraday's law, the total sulfur content of the sample is calculated.
Total Sulfur Determination in Petroleum and Chemical Products
SH/T0253-92Total Sulfur Content Determination Method in Light Petroleum Products (Electrical Method) Standard
2GB/T11061-1997 Total Sulfur Determination in Natural Gas - Oxidation Microcoulometry Standard
3SH/T0222-1992 Method for Determining Total Sulfur Content in Liquefied Petroleum Gas (Electrical Method) Standard
4SY/T7508-1997 Determination of Total Sulfur in Liquefied Petroleum Gas from Oil and Gas Fields - Oxidation Microcoulometric Method Standard
5GB/T11141-1989 Determination of Trace Sulfur in Light Olefins—Oxidation Microcoulometric Method Standard
6Standard for the Determination of Trace Sulfur in Industrial Styrene by Oxidation Microcoulometry - GB/T12688.6-1990
7、GB/T63244-1986Determination of Trace Sulfur in Organic Liquid Products-Microcoulometric method Standard
8、GB/4396-2005Total Sulfur Content Determination Method
Technical Specifications
● Analytical Elements: Sulfur | |
● Method Principle: Coulometric Titration, Electrometric Method | |
● Standard: GB/T15959-1995; SH/T0253 | |
● Current Occurrence: ±2mA | |
● Electrolytic Voltage: ±15V | |
● Bias Range: 10 ~ 400 mV | |
● Measurement Range: 0.1~10,000 mg/L | |
●Reproducibility Error: x ≤ 0.5mg/L < 30%; 0.5mg/L < x ≤ 1.0 mg/L < 10% | |
1.0mg/L < x ≤ 10 mg/L <8% x >10 mg/L <4% | |
●Temperature Control Range: Room Temperature ~ 1100℃ |
Features
● Titration cell has a long stable timeS Greater than 12 HourClGreater than 8 Hour(s)
● Single-point and multi-point calibration options available
● Historical data and graphic playback for easy comparison and analysis.
● During liquid sample analysis, automatic sample loading/Auto-start
● Select the appropriate sampler for analysis of solid and gaseous samples.AOXAnalyze with the addition of a solid sampler.
● USB Interface, compatible with computers of any model, optional configuration
● ACCESS Database, Auto-Save Historical Parameters and Data
● Support for LIMS System Connection
Products and scientific research applied in environmental monitoring, oil, chemical industry, metallurgy, and universities.