Zhenyuan Series Chlorine Dioxide Generator Performance Features
ØTo fully extend the reaction time of raw materials, enhance the chlorine dioxide content, and improve the conversion rate of raw materials, domestic counterparts in the same industry use a five-stage reactor, with the reaction time of raw materials in the reactor being1.95Hours, Total Material Conversion Rate ≥90Chlorine dioxide constitutes a percentage of the total available chlorine.70-80%。
ØDomestic dry heating methods offer quick temperature rise with low power consumption, demonstrating significant energy savings compared to similar products in the industry..
ØDomestic direct measurement reactors measure the actual reaction temperature inside, rather than the medium temperature. Temperature control:45℃-50℃。
ØDual temperature control system designed for large equipment, maintaining a high raw material conversion rate for use in cold regions.
ØUsing a residue separator device can enhance the purity of water intended for drinking.
ØMaterial conveyance is equipped with imported electromagnetic metering pumps, which operate stably with precise and reliable measurement.
ØThe reactor inside the equipment is made of high-temperature and corrosion-resistant synthetic metal materials or pure titanium, ensuring a long service life for the equipment.10Over one year.
ØSelf-developed and produced chlorine dioxide generator controller, integrating temperature control, frequency adjustment, flow control, residual chlorine control, and logical control into one unit, making the equipment more user-friendly and convenient for selection.
ØTemperature control is implementedPIDTechnology, temperature control. Set temperature cut-off function to prevent loss due to uncontrolled temperature.
ØThe controller features logical control functions: only after the dynamic water pressure and two liquid level conditions are met can the equipment start heating and operate normally.
ØOperation: The specially designed explosion-proof device features reversible functionality, allowing it to effectively release excessive pressure within the reactor and rapidly restore itself.
ØBased on user selection to meet20Tanks for raw materials storage, lasting up to several days; continuous level measurement for large raw material tanks with remote transmission capability.
ØEasily facilitates the automation of equipment operation processes. Extremely simple to achieve联动 control with the equipment you require.
ØA good installation pattern ensures the absence of chlorine dioxide or corrosive gases indoors, as well as noise and leakage pollution.
Detailed description of performance features:
1.Sodium chlorateNaClO3And hydrochloric acid (concentration ≥)31A composite disinfectant primarily produced with chlorine dioxide as the main ingredient and chlorine gas as a secondary ingredient.
2.Zhenyuan Equipment fully utilizes the working principle of water jets to generate negative pressure. The reactor inside the equipment is always in a negative pressure state, and due to the entry of air, the raw materials are continuously aerated. The chlorine dioxide gas produced in each reactor is continuously extracted, resulting in higher chlorine dioxide output, measured by effective chlorine content.ClO2Concentration exceeding70。
3.To fully extend the reaction time of raw materials, enhance the chlorine dioxide content, and improve the conversion rate of raw materials, the equipment employs a five-stage, segmented reactor design, with a production yield of ≥90Chlorine dioxide accounts for a portion of the total available chlorine.70-80%。
4.Domestic five-grade reactor, raw material residence time in the reactor reaches1.95Hours, ensuring that the raw materials undergo full reaction within the reactor, thus guaranteeing a high yield of the reaction.90Above.
5.Five-stage Reactor Mechanism: Sodium chlorate and hydrochloric acid react at room temperature, producing a significant amount of chlorine dioxide gas. The raw material conversion rate is low, so the first four stages of reaction can fully extract a large amount of chlorine dioxide gas. Starting from the fifth stage, heating is applied to ensure full reaction of the raw materials. At this point, there is more chlorine and less chlorine dioxide, which can ensure an increased raw material conversion rate and a higher proportion of effective chlorine to chlorine dioxide.
6.The equipment employs dual-temperature control technology to enhance raw material conversion rates, capable of increasing raw material conversion rates by75Above. The specific method involves using a water bath heating for the first four reactors, heating to30~40°C, Level 5 uses dry heating up to45~50℃。
7.The equipment is enhanced with a residue treatment system, which can expel any minimal unreacted residues.
8.Due to the full reaction of the raw materials, the content of chlorates in the disinfected water body is significantly reduced, meeting the requirements of national drinking water standards: chlorates below0.7ppm。
Automatic temperature control, temperature regulation45-50The equipment utilizes a combination heating system with water bath heating as the main method and air heating as the auxiliary. Currently, domestic hypochlorous acid generators using negative pressure technology all adopt an external air blowing-off process to remove chlorine dioxide generated from the reaction liquid, which is then absorbed by a water jet to produce disinfectant solution. However, this process has a flaw: the actual temperature inside the reaction chamber does not reach the required reaction temperature. This is because the equipment's operation...(Especially during winter)Outdoor temperatures are generally0Below °C, during the blowing-off process, the outdoor cold air significantly lowers the temperature of the reaction liquid, preventing the reactor from reaching the required temperature and drastically reducing the conversion rate of the raw material. In response to this actual usage scenario, our company has innovated through technology by adding air-assisted heating at the equipment's air intake, pre-heating the cold air before blowing-off, thereby avoiding the aforementioned issues. This air-assisted heating can achieve automatic temperature control, ensuring that the air blown into the system remains at a constant temperature regardless of the outdoor temperature.40°C, which allows for maintaining a constant reaction temperature within the reactor throughout the year. This is a highlight and unique feature of our generator compared to similar products. This technology has been applied for a national invention patent by our company. Additionally, due to the rapid heat exchange in the reaction vessel, it significantly reduces the lifespan of the reactor. This device effectively overcomes...