BJY Series Explosion-proof Cleanroom Fluorescent Lamps(ⅡC)
BJY Series Explosion-proof Cleanroom Fluorescent LampsApplication Range Application
Zone 1, Zone 2 - Hazardous Areas
IIA, IIB, II Class Explosive.
Mounted Light Source: Single-tube or double-tube lamps: 40X (36W X 2, 40(36)W X 1, 20(18)W X 2, 20(18)W X 1. Suitable for use in Zone 1 and Zone 2 hazardous areas.
Can be used in IIA、IIB、IIC group explosive atmosphere.
Equipped with luminous source:One foot light tube or common
light in a feet tube:40(36)Wx2、40(36)Wx1、20(18)Wx1.
BJY Series Explosion-proof Cleanroom Fluorescent LampsModel Meaning
BJY Series Explosion-proof Cleanroom Fluorescent LampsFeatures Features
Shell made of steel moldingThe clear cover is made by polycarbonate molding.
The shell is formed by steel plates of high grade,the transparent enclosure is
pressed to formation by poly-carbonate.
The overall structure features a sealed design.Highly waterproof and dustproof.
Use sealed structme,with the functions of strong water-proof and dust-proof.,
Single-foot lamp tube insideFast instantaneous start, customizable according to customer requirements The inside packs a footight tube,the fleetness starts in a moment,can accordingto customer request refit the one foot light tube.
The lighting fixture can be equipped with emergency devices upon request.Emergency device is equipped with emergency The emergency device may be installed as requited,which consists of controller
Controller and nickel battery make up two parts, the emergency controller features over...
and cadium battery,the controller has functions of charging nd discherging
Charging and over-discharge protection features. Over-voltage.
CompliantGB3836-2000, IEC60079 standards requirements Suitable for GB3.836-2000,IEC6007 standard raquest.
BJY Series Explosion-proof Cleanroom Fluorescent LampsPrimary Technical Parameters Main technical parameters
Blast-Proof Mark Rated Voltage (V) Protection Class Cable Outer Diameter (Diameter, mm) Thread of Entry Port (G")
Ex-mark Rated voltage Protection Cable's outside Inlet's thread grade diameter
Exdemb Ⅱ CT5 Gb 220V/50Hz IP65 10~14 3/4
Supplied with light source
Supplied with lamp 20(18)W x 1 20(18)W x 2 40(36)W x 1 40(36)W x 2
Emergency Equipment Specifications
Emergency Start Time Charging Time (h) Emergency Lighting Time (min)
0.3 90
Outline and Mounting Example
Embedded 1 (q1): Insert Type 1 CBY-J-□20X2q1; Ceiling Type (x)
Embedded 1 (q1): Insert type 1 CBY-J-□20X2q1 Ceiling Mount (x): Ceiling type