Hybrid Iron Wet Flue Gas Desulfurization Technology_SupplyPro Co., Ltd._Chelated iron wet flue gas desulfurization technology, supply, machinery and equipment website, harmless treatment equipment_Shandong Fengshuo Environmental Protection Technology Co., Ltd._Zhongshang 114 Industry Resources Network
Shandong Fengshuo Environmental Protection Technology Co., Ltd.

Desulfurization equipment, desulfurization towers, desulfurization tanks, biogas desulfurization, hydrogen sulfide desulfurization, etc. desulfurization projects

全国服务咨询热线
13356795255


Hybrid Iron Wet Flue Gas Desulfurization Technology

价      格Negotiable

最小起订0 Piece库存0 Piece

发货时限
3 Days发货
Location
Shandong Weifang
有效期至
长期有效
最后更新
2022-03-29 19:07
View Count
97

Business Card

  • Your company's名称Shandong Fengshuo Environmental Protection Technology Co., Ltd.
  • 联 系 人李英杰 (先生)
  • Your company'sPhone13356795255
  • Mobile号码13356795255
  • Company AddressNo Chinese content provided.

买家正在看

  • Biogas Equipment - Biogas Torch

    Negotiable

  • Biogas boiler

    Negotiable

  • Chelated Iron Desulfurization System

    Negotiable

  • Biogas Storage Equipment

    Negotiable

Product Details

I. Basic Principle of Wet Flue Gas Desulfurization Process with Complexed Iron
Desulfurization Principle
Overall reaction equation for oxidation absorption
H2S(g)+2Fe3+(L)→2H+(L)+S↓+2Fe2+(L)
2. Recycled Principles
To restore the solution's ability to absorb hydrogen sulfide, the solution is regenerated, with the regeneration process primarily involving oxidation and sulfur precipitation reactions:
1/2O2(g)+H2O(L)+2Fe2+(L)→2OH-(L)+2Fe3+(L)
II. Technical Features
High desulfurization efficiency.
(2) The system boasts strong anti-jamming capabilities.
(3) Low operation costs.
(4) The process has high selectivity and no by-products.
(5) High sulfur capacity.
(9) No waste water discharge, no hazardous waste generation.
Section 3: Application Scope: Hydrogen sulfide removal from biogas, associated petroleum gas, and industrial vent gas, with gas volume less than 100,000 Nm3/d. The hydrogen sulfide content in the feed gas is not limited, and the desulfurization accuracy is less than 10 PPm.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
13356795255