Hydrogen Sulfide Removal Technology by Complexed Iron Wet Desulfurization_SupplyPro Co., Ltd._Chelated iron wet flue gas desulfurization technology, supply, machinery and equipment website, harmless treatment equipment_Shandong Fengshuo Environmental Protection Technology Co., Ltd._Zhongshang 114 Industry Resources Network
Shandong Fengshuo Environmental Protection Technology Co., Ltd.

Desulfurization equipment, desulfurization towers, desulfurization tanks, biogas desulfurization, hydrogen sulfide desulfurization, etc. desulfurization projects

全国服务咨询热线
13356795255


Hydrogen Sulfide Removal Technology by Complexed Iron Wet Desulfurization

价      格Negotiable

最小起订0 piece库存0 piece

发货时限
3 Days发货
Location
Shandong Weifang
有效期至
长期有效
最后更新
2022-03-29 19:07
View Count
93

Business Card

  • Your company's名称Shandong Fengshuo Environmental Protection Technology Co., Ltd.
  • 联 系 人李英杰 (先生)
  • Your company'sPhone13356795255
  • Mobile号码13356795255
  • Company AddressNo Chinese content provided.

买家正在看

  • Chelated Iron Desulfurization Equipment

    Negotiable

  • Biogas Gasometer

    Negotiable

  • Hydrogen Sulfide Removal Technology by Complexed Iron Wet Desulfurization

    Negotiable

  • Biogas Equipment - Independent Double Membrane Flexible Gas Storage Vessel

    Negotiable

Product Details

Basic Principle of Wet Flue Gas Desulfurization with Chelating Iron
Desulfurization Principle
Total Absorption Oxidation Reaction Equation
H2S(g)+2Fe3+(L)→2H+(L)+S↓+2Fe2+(L)
2. Recycling Principle
To restore the solution's ability to absorb hydrogen sulfide, the solution is regenerated, with the regeneration process primarily involving the oxidation and precipitation of sulfur.
1/2O2(g)+H2O(L)+2Fe2+(L)→2OH-(L)+2Fe3+(L)
Section II: Technical Features
High desulfurization efficiency.
(2) The system boasts strong anti-vibration capabilities.
(3) Low operating costs.
(4) The process has high selectivity and no by-products.
(5) High sulfur capacity.
(9) No wastewater discharge, no hazardous waste generation.
Section 3: Application Range: Hydrogen sulfide removal from biogas, associated petroleum gas, and industrial vent gas, with gas flow rate less than 100,000 Nm3/d; no limit on the hydrogen sulfide content in the feed gas; sulfur removal accuracy less than 10 PPm.