

价 格Negotiable
最小起订0 piece库存0 piece
High-Throughput Intelligent Micro
Negotiable
GGC-W Automatic Inverted Oscillat
Negotiable
GGC-CS Series Vortex Liquid Separ
Negotiable
GH-800 Infrared Spectrophotometri
Negotiable
GXC Fully Automatic Rotating Osci
Negotiable
600ST Sulfuric Acid Oxidation Ble
Negotiable
GGC-A Integrated Intelligent Dist
Negotiable
GGC-AS Sulfide Acidification Dist
Negotiable
GGC-600S Water Quality Sulfide Ox
Negotiable
GGC-Q Automatic Liquid-Liquid Ext
Negotiable

The GH-24D Soil Dryer utilizes a dual-mode heating system with a drying chamber module and hot air circulation, accurately simulating indoor air flow patterns for soil drying in wind-drying mode. The dry air is clean, heated air that has been filtered and activated carbon adsorbed, ensuring individual storage and drying of samples in separate compartments, thus avoiding cross-contamination; it saves time, effort, and space, and improves the efficiency of soil drying. It meets the following standards for wind-drying of samples: GB/T 32722-2016 "Guidelines for Long-term and Short-term Storage of Soil Samples"; HJ/T 166-2004 "Technical Specification for Soil Environmental Monitoring"; NY/T 1121.1-2006 "Soil Testing - Part 1: Collection, Treatment, and Storage of Soil Samples"; HJ/T 20-1998 "Technical Specification for Sampling and Sample Preparation of Industrial Solid Wastes."
Introduction
The GH-24D Soil Dryer utilizes a dual-mode heating system with a drying cabinet module and hot air circulation, accurately simulating indoor air flow patterns for soil drying in wind-drying mode. The dry air is a clean, hot air that has been filtered and activated carbon adsorbed, ensuring the samples are stored and dried in separate compartments to maintain cleanliness and prevent cross-contamination. It offers time-saving, labor-saving, space-saving, and improved soil drying efficiency. It meets the following standards for wind-drying of samples: GB/T 32722-2016 "Guidelines for Long-term and Short-term Storage of Soil Samples - Soil Quality," HJ/T 166-2004 "Technical Specification for Soil Environmental Monitoring," NY/T 1121.1-2006 "Soil Testing - Part 1: Collection, Treatment, and Storage of Soil Samples," and HJ/T 20-1998 "Technical Specification for Sampling and Sample Preparation of Industrial Solid Waste."
II. Technical Specifications
Power Voltage: 220V, 50Hz
2. Power: 1600W
3. Dry Air Temperature Range: Room temperature - 60℃*24, temperature control accuracy ±1℃ (digitally adjustable)
4. Number of sample rooms: 24.
5. Working Environment: Temperature 20-40°C; Relative Humidity 10%-80%; Dry Room Temperature 40°C with Air Purification Equipment
6. Sample Room Dimensions (mm): 360 x 260 x 180 (Length x Width x Height)
7. Instrument Dimensions (mm): 1380 x 500 x 1680 (Length x Width x Height)
Heating block size (mm): 150*150 (Length x Width)
8. Control Mode: Each of the 24 independent sample rooms is individually controlled by 24 separate temperature sensors and control panels.
III. Key Features
Utilizing air disturbance technology, the dual air source simulates indoor air flow, significantly approximating the indoor environment and achieving rapid air drying.
2. Utilizes advanced air filtration and adsorption technology, featuring a total exhaust outlet (can be connected to an exhaust pipe) to prevent secondary cross-contamination of the sample.
3. The drying oven heating block is made of imported infrared ceramic heating, which ensures even heating and a long service life.
4. The sample box features an individual sample room, separating samples to prevent cross-contamination.
5. Sample room made of stainless steel, resistant to chemical corrosion and organic matter adsorption; easy to clean.
6. The sample room features a transparent observation area for easy customer monitoring of sample conditions at any time.
7. The sample room is equipped with enameled trays and stainless steel trays, which can directly hold general soil samples, as well as high moisture content samples like riverbed mud.
Each sample room is equipped with an independent heating module, significantly improving the temperature range and accuracy within each room, effectively enhancing the uniformity of temperature control, and ensuring no interference between adjacent sample rooms.
9.7-inch large LCD touch screen, easy to operate.
10. The gas source is internally placed within the drying cabinet, which is equipped with complete noise insulation. It boasts low noise levels, a small footprint, simple operation, and easy maintenance.
Each sample box can be controlled and maintained at a consistent temperature independently.
Equipped with two high-power ultra-quiet air purifying pumps, capable of accelerating air circulation.
13. The sample room is spacious, capable of accommodating five-kilogram samples for easy drying.
14. Wastegases are collected uniformly and can be discharged outdoors through a common pipeline.
15. The soil desiccator comes with casters at the bottom for easy mobility.





Phone Consultation