Shenzhen Zhongnuo Testing Technology Co., Ltd. specializes in the calibration, certification, and measurement services for gas detectors, combustible gas detectors, and toxic gas analyzers, catering to various facilities. With qualifications to serve nationwide, we address all types of electrical safety and explosion-proof fire prevention issues for our clients, contributing to safe production.
The calibration cycle for flammable gas detectors is typically once a year.
In accordance with the standard JJG 693-2011 "Flammable Gas Detectors," the calibration period for flammable gas detectors generally does not exceed one year. This means that under normal circumstances, a comprehensive calibration and testing of the flammable gas detectors should be conducted annually to ensure their performance meets the relevant requirements.
GB 12358-2024 "General Technical Requirements for Environmental Gas Detection and Alarm Instruments in Workplace" is an important standard.
Intended to standardize the performance, functions, and testing methods of environmental gas detection alarm instruments used in work sites.
The standard was published in 1990 and has undergone multiple revisions.
The new version is GB 12358—2024, which will be officially implemented on June 1, 2025.
This standard applies to the production and use of gas detection and alarm instruments for flammable gases, toxic and harmful gases, and oxygen in work places.
How often should various gas detectors be calibrated and tested?
Instrument recalibration is typically every 1 year, determined by the submitting unit based on actual usage. During the secondary calibration process, recalibration is required if there are doubts about the instrument's test data, if the main components of the instrument are replaced, or if recalibration is needed after repairs.
Gas Standard Material
We use gas standard substances of the same type as the gas measured by the instrument, such as methane or ethane, or other gases like isopropanol can be used as standards. If the instrument does not specify the type of gas being measured, the concentration of the gas at the set point should be approximately 60% of the full scale, using a standard substance. The uncertainty of the expanded gas standard substance is not significant (%), and the standard substance should have a repeatability of more than 1%. The flow indication error of the dilution device should not be greater than 0.%. The concentration unit of the gas standard substance should be converted to match the indicating unit of the tested instrument, and the value should not exceed 0.%.
Shenzhen Zhongnuo Testing Technology Co., Ltd. is a third-party service provider specializing in electrical safety, electrical explosion-proof, gas alarm, and toxic gas detection equipment for regular calibration, measurement, and verification. We hold the necessary qualifications to address fire and explosion prevention issues for our clients.