Utilizing liquid nitrogen cooling, the instrument achieves linear temperature reduction by controlling the flow of liquid nitrogen, capable of reaching as low as -160 degrees Celsius. Differential Scanning Calorimetry (DSC) is a classic thermal analysis method that analyzes thermal effects at controlled program temperatures, and it has long been widely applied in various fields such as research and development of materials and chemicals, process optimization, quality inspection and control, and failure analysis. Using the DSC method, we can study phase transitions in inorganic materials, melting and crystallization processes of polymers, polymorphic phenomena in drugs, solid/liquid phase ratios in foods like fats and oils, etc. Complies with national standards GB/T2951.42-2008, GB/T15065-2009, GB/T17391-1998, GB/T19466.6-2009.



Technical Features

1. The instrument can achieve linear cooling down to -120°C by controlling the flow of liquid nitrogen.

2. One-touch temperature calibration, eliminating complex calibration steps.

3. Enhanced PID temperature control system for more precise temperature regulation.

4. Utilizing imported sensors to enhance sensitivity and accuracy.

5. Industrial-grade wide-screen touch structure with rich display information, including set temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, and various switch states.

6. USB communication interface with strong versatility, reliable signals without interruption, and supports self-recovery connection function.

7. The furnace body features a compact structure with adjustable heating and cooling rates.

8. Enhanced installation techniques, now fully using mechanical fastening methods, completely avoiding the contamination of differential thermal signals by the internal gel of the furnace.

9. Dual-temperature probe ensures high repeatability in sample temperature measurement.

10. The digital gas mass flow meter automatically switches between two gas flow paths, with fast switching speed and short stabilization time.

11. Standard sample included for customer convenience in adjusting temperature coefficients.

12. Software adapts to various computer screen resolutions; supports laptops, desktops, and operates on Windows 2000, XP, Windows 7, Windows 8, Windows 10, and other operating systems.

13. Supports user-programmable routines for full automation of measurement steps. The software offers dozens of commands, allowing users to flexibly combine instructions based on their specific measurement procedures and save them. Complex operations are simplified into one-click actions.


Technical Specifications

1. DSC Range: 0 ~ ±250 mW

2. Temperature Range: -150~725℃

3. Heating Rate: 0.1~50℃/min

4. Cooling Rate: 0.1~10℃/min

5. Temperature Resolution: 0.01℃

6. Temperature Accuracy: ±0.1℃

7. Temperature Repeatability: ±0.1℃

8. DSC Accuracy: ±2%

9. DSC Resolution: 0.001 mW

10. DSC Resolution: 0.001 mW

11. Temperature Control Methods: Heating, Constant Temperature, Cooling, and Circulating Temperature Control (fully automatic program control)

12. Curved Scan: Heating Scan

13. Atmosphere Control: The gas quality flow meter automatically switches between two gas lines.

14. Display Method: 24-bit color, 7-inch LED touch screen display

15. Data Interface: USB standard interface, with corresponding operation software.

16. Parameter Standard: Equipped with standard calibration items, featuring a one-touch calibration function, allowing users to calibrate temperature independently.

17. Operating Power: AC220V, 50Hz/60Hz


Application Examples

Measure physical and chemical changes related to heat, such as glass transition temperature, melting point, fusion temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/cross-linking, oxidation induction period, reaction kinetics, specific heat, etc.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery All Cities
Brand No content provided.
Manufacturer Direct Sales
Supply Volume 999
Supported Customized
Expiry Long Valid
Update 2025-11-16 15:39
Gallery

Shanghai Yanjin Scientific Instrument Co., Ltd.Published byDSC-750L Differential Scanning Calorimeter (-150 to 725°C)Gallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top