名称:Microcomputer Fully Automatic Isothermal Calorimeter
Model: BYLRY-8000B
Suitable for measuring the calorific value of combustible materials such as coal, coke, coal gangue, fly ash, oil, and black raw cement in industries like electricity, coal, biomass, petroleum, chemicals, cement, building materials, feed, food, and scientific research.
Meets Standards:
This product complies with GB/T213-2008 "Method for Determining the Calorific Value of Coal", GBT30727-2014 "Method for Determining the Calorific Value of Solid Biomass Fuel", GB-T384-1981 "Method for Determining the Calorific Value of Petroleum Products", JC/T1005-2006 "Method for Determining the Calorific Value of Cement Raw Materials", and ASTM D5865-2007 "Standard Test Method for Total Calorific Value of Coal and Coke."
Technical Features:
Automatically measure the water level in the inner cylinder, adjust water temperature, and complete the entire testing process automatically. Automatically regulate the outer barrel temperature, ensuring test results are unaffected by environmental changes or the number of tests. Long-term stability in heat capacity.
Utilizing high-tech noiseless refrigeration units with advanced temperature control systems, and a water circulation system featuring German magnetic pumps.
The hardware incorporates a 16-bit microcontroller and programmable integrated circuits. The circuit board connectors are all made with German Phoenix components, ensuring high reliability.
Utilizing fuzzy logic control technology, it achieves high temperature control accuracy and excellent stability.
Utilizing the RS485 bus, one host can control two calorimeters or one.
Utilizing a 24-bit A/D converter with high-temperature qualification, ensuring the temperature measurement accuracy, test linearity, and precision comply with GB/T213-2008 "Determination of Calorific Value of Coal."
The software is developed using VC++, employing object-oriented software design principles.
All-Windows interface, powerful features, easy operation, reliable performance. Detailed test data recording, multiple query methods.
Highly versatile, users can set various parameters as needed.
Technical Specifications:
Precision: ≤0.1%
Temperature Range: 5-65°C
Resolution: Better than 0.0001℃
Repeatability of heat capacity: 0.05% - 0.2%.
Test Time: 15 mins (Standard Method), 10 mins (Rapid Method)
Ambient Temperature: 10-40℃
Power: 220V ±22V, 50Hz ±1Hz
Power: ≤0.5KW
Dimensions: 750×500×420 mm.