Rubber Mooney ViscosityInstrument
1.Features and Applications: This machine conforms toGB/T 1232"Determination of the Mooney Viscosity of Unvulcanized Rubber"GB/T1233"Determination of Initial Vulcanization Characteristics of Rubber Compounds - Mooney Viscosity Gauge Method"ISO289、ISO667Standards for measuring the viscosity, scorching, and curing indices of raw or compounded rubber. Microcomputer controlled, with data display, automatic calibration, it is an ideal experimental instrument for the rubber industry and research units. Equipped with imported intelligent digital temperature control instruments, it offers simple adjustments and a wide temperature control range. The microcomputer uses imported chips for high reliability, with all data capable of automatic graphing, calculation, and printing.
Technical specifications and standards
Standard of Execution:ISO28-63、GB/T3242-2005
Temperature Measurement Range: Room Temperature~200℃
Temperature Accuracy:≤±0.3℃
Control Precision:≤±0.3℃
Temperature Resolution:0.1℃
Torque range:0-100Mooney viscosity
Calibration Accuracy:100±0.5Mooney Value
Rotor Speed:2±0.02Please provide the Chinese content to be translated./Please provide the Chinese content to be translated.
Measurement Time:0-200Resolution1Second
Ambient Temperature:0-35℃
Relative Humidity:<80%
Test Pressure:11.5KN±0.5KN
Pressure:0.45-0.6MPa
II.Rubber Mooney Viscosity GaugeEquipment Components
The computerized rubber automatic door Mooney viscosity tester is composed of several parts: the data processing system, data acquisition system, and mechanical system.
2.1Data Collection System
1.High-precision sensor:0-100A Meniscus Value. The Meniscus value accuracy is±0.5Within a specific Mooney value, resolution:0.1A Mohs hardness value.
Utilizing intelligent temperature control gauges for real-time automatic operationPIDControl.
2.2Mechanical System
Utilizing a variable-speed motor and a reducer.Large转子Φ38.10 ±0.03 Flat teeth count24、AndSmall rotorΦ30.48 ±0.03 Planetary gears19,RotorAlloy steel material.
2.3Data Processing System
Input Methods: Keyboard, mouse, or host panel buttons.
Control System: Utilizes computer control and interface boards for data collection, storage, processing, and printing of test results and curve processing.
Output Methods: Display, Print.
2.4Work Conditions
Power SupplyCommunication220V ±10%,50HZ
Ambient Temperature0-35℃
Relative Humidity (RH)<70%
2.5
Rubber Mooney Viscosity GaugeTechnical documents and accessories
Name | Unit | Quantity | |
1 | Manual | Copy | 2 |
2 | Test Software (CD) | Piece | 2 |
3 | Standard Computer | Tai | 1 |
4 | LaserA4Color Printer | Tai | 1 |
5 | Air Compressor (Pressure)0.8MPa) | Tai | 1 |
6 | Electrical Schematic | Piece | 2 |
7 | Certificate of Compliance | Please provide the Chinese content to be translated. | 1 |
8 | Parts List (including manufacturers) | Piece | 1 |
Service and Quality Certificate
Our company offers free operation training and technical guidance to the users during the product delivery period. We promptly respond to any inquiries and doubts raised by customers, and handle quality issues with seriousness. Hereby, we solemnly state:
1. Department in Charge: Sales Company. Contact Person: Mr. Tong, Phone: .
2. Service Response Time:
If a customer encounters a product quality issue that needs to be addressed, upon notifying our Marketing Department, the department will promptly address the issue with all relevant departments within 2 hours. If on-site resolution is required, a service, technical, and repair team will be dispatched to the location within 24 hours to resolve the issue, analyze the cause, and implement quality improvements.
3. During the quality warranty period, we assume responsibility for quality issues caused by design, manufacturing processes, or material defects. We offer free repairs or replacements for non-conforming parts to ensure the normal operation of the equipment.
Rubber Mooney Viscosity GaugeService and Quality Certificate
Our company provides free operation training and technical guidance to users during the product delivery and usage period. We promptly respond to users' inquiries and doubts, and handle quality issues meticulously. We solemnly state the following:
1. Department Responsible: Sales Company.Contact Person: Mr. Tong, Phone:。
2. Service Response Time:
If a customer encounters a product quality issue that needs to be addressed, upon notifying our Marketing Department, the department will promptly handle the matter, along with relevant departments, within 2 hours. If on-site resolution is required, a service, technical, and repair team will be dispatched to the location within 24 hours to resolve the issue, analyze the cause, and implement quality improvements.
3. During the quality warranty period, our company is responsible for any quality issues caused by design, manufacturing processes, or material defects. We offer free repairs or replacements for non-conforming parts to ensure the normal operation of the equipment.