JZ-6028 modelMeniscus Viscosity TestAppliance 1.Features and Applications: This unit conforms toGB/T 1232"Determination of the Mooney Viscosity of Unvulcanized Rubber"GB/T1233"Determination of Initial Vulcanization Characteristics of Rubber Compounds by Mooney Viscosity Meter"ISO289、ISO667Standards for determining the viscosity, scorching, and curing index of raw rubber or compounded rubber. Microcomputer controlled, with data display, automatic calibration, ideal for rubber industry and research units as experimental equipment. Utilizes imported intelligent digital temperature control instruments, easy to adjust and set, with a wide temperature control range. The microcomputer employs imported chips, ensuring high reliability, with all data capable of automatic graphing, calculation, and printing. Technical specifications and metrics II.Component of Equipment The rubber automatic door Mooney viscosity gauge consists of several parts: the data processing system, data acquisition system, and mechanical system. 2.1Data Collection System 1.High-precision sensor:0-100A Meniscus Value. The Meniscus value accuracy is±0.5Within a specific Mooney value, resolution:0.1A Meniscus Value. Utilizing an intelligent temperature control gauge, real-time automaticPIDControl. 2.2Mechanical System Utilizing a variable-speed motor and a reducer, featuring:Large flywheelΦ38.10 ±0.03 Planetary gears24、AndSmall rotorΦ30.48 ±0.03 Planetary gear teeth19,RotorAlloy steel material. 2.3Data processing system Input Methods: Keyboard, mouse, or host panel buttons. Control System: Utilizes computer control and interface boards for data collection, storage, processing, and printing of test results and curve processing. Output Methods: Display, Print. 2.4Work Conditions Power SupplyCommunication220V ±10%,50HZ Ambient Temperature0-35℃ Relative humidity of environment<70% 2.5 Technical documents and accessories Name Unit Quantity 1 Instruction Manual Copies 22 2 Test Software (CD) Copies 23 3 Standard Computer Sets 14 4 Laser A4 Color Printer Sets 15 5 Air Compressor (Pressure 0.8MPa) Sets 16 6 Electrical Schematic Diagrams Copies 27 7 Certificate of Compliance Copies 18 8 List of Vulnerable Parts (including Manufacturer) Copies 1
Our company provides free operation training and technical guidance to users during the supply period, promptly responds to inquiries and doubts raised by customers, and handles quality issues diligently. We solemnly state as follows: |
Meniscus Viscosity TestAppliance
One.Features and Applications: This machine conforms toGB/T 1232"Determination of the Mooney Viscosity of Unvulcanized Rubber"GB/T1233"Determination of Initial Vulcanization Characteristics of Rubber Compounds Using the Mooney Viscosity Meter"ISO289、ISO667Compliance with international standards, used for measuring the viscosity, scorching, and curing index of raw rubber or compounded rubber. Microcomputer control, data display, automatic calibration make it an ideal experimental instrument for the rubber industry and research institutions. Equipped with imported intelligent digital temperature control instruments, it offers easy adjustment and a wide temperature control range. The microcomputer uses imported chips for high reliability, with all data capable of automatic graphing, calculation, and printing.
Meniscus Viscosity TestInstrument Technical specifications and standards
Standard of Execution:ISO28-63、GB/T3242-2005
Temperature Control Range: Room Temperature~200℃
Temperature Accuracy:≤±0.3℃
Control Accuracy:≤±0.3℃
Temperature Resolution:0.1℃
Torque Range:0-100Mooney Value
Calibration Accuracy:100±0.5Mooney Value
Rotor Speed:2±0.02Please provide the Chinese content to be translated./Please provide the Chinese content to be translated.
Measurement Time:0-200Resolution1Second
Ambient Temperature:0-35℃
Relative Humidity:<80%
Test Pressure:11.5KN±0.5KN
Pressure:0.45-0.6MPa
II.Meniscus ViscometerComponents of the equipment
The computerized rubber automatic door Mooney viscosity tester is composed of several parts, including the data processing system, data acquisition system, and mechanical system.
2.1Data Collection System
1.High-precision sensor:0-100A meniscus value. The meniscus value accuracy is±0.5Within a Durometer value, resolution:0.1A Meniscus Value.
Equipped with an intelligent temperature control gauge for real-time automaticPIDControl.
2.2Mechanical System
Utilizing variable speed motors and reducers.Large flywheelΦ38.10 ±0.03 Planetary gears24、AndSmall rotorΦ30.48 ±0.03 Flat teeth19,RotorAlloy steel material.
2.3Data Processing System
Input Methods: Keyboard, mouse, or host panel keys.
Control System: Utilizes computer control and interface boards for data collection, storage, processing, and printing of test results and curve processing.
Output Methods: Display, Print.
2.4Work Conditions
Power SupplyCommunication220V ±10%,50HZ
Ambient Temperature0-35℃
Relative Humidity (RH)<70%
2.5
Meniscus Viscosity TestApplianceTechnical documentation and accessories
Name | Unit | Quantity | |
1 | Manual | Piece | 2 |
2 | Test Software (CD) | A piece | 2 |
3 | Standard computer | Tai | 1 |
4 | LaserA4Color Printer | Tai | 1 |
5 | Air Compressor (Pressure)0.8MPa) | Tai | 1 |
6 | Electrical Schematic | Copy | 2 |
7 | Certificate of Conformity | A piece | 1 |
8 | Parts List (including manufacturers) | Copy | 1 |
Service and Quality Manual
Our company provides free operation training and technical guidance to users during the delivery and use of our products. We promptly respond to users' inquiries and doubts, and handle quality issues meticulously. We solemnly state the following:
1. Department Responsible: Sales Department. Contact: Mr. Tong, Phone: .
2、Meniscus Viscosity TesterService Response Time:
If a customer reports a product quality issue that needs to be addressed, our Marketing Department will promptly review the matter with all relevant departments within 2 hours. If on-site resolution is required, our after-sales, technical, and repair teams will be dispatched to the location within 24 hours to resolve the issue, analyze the cause, and implement quality improvements.
3. During the quality warranty period, we assume responsibility for quality issues caused by design, manufacturing processes, or material defects. We offer free repairs or replacements for non-conforming parts to ensure the normal operation of the equipment.