Structural Principles
The LC3010 series is composed of the original DLC3000 Smart Level Controller, a float measuring chamber, measuring mechanism, float, torsion tube, and more. The float is submerged in the liquid within the measuring chamber and rigidly connected to the torsion tube system. The force the torsion tube system withstands is the net weight of the float minus the buoyant force exerted by the liquid. This resultant force twists the torsion tube to a certain angle. Changes in the position, density, or interface levels of the measured liquid cause the float to move, which is then transmitted to the torsion tube assembly, causing it to rotate. The rotational movement of the torsion tube is transferred to the lever of the smart level controller, causing a magnet fixed on the lever assembly to displace, altering the magnetic field detected by the Hall effect sensor and converting it into an electrical signal. The transmitter employs a microcontroller and related electronic circuits to measure process variables, providing a 4-20mA current signal output in a two-wire system, and drives an LCD liquid crystal display while offering HART communication capability. The microcontroller within the transmitter not only has environmental temperature compensation and linearization processing functions but also compensates for changes in liquid density caused by process temperature variations.
Features
Process Temperature: -196°C to +400°C
Pressure Class: PN 1.6, 4.0, 6.3, 10, 16, 25, 32 MPa
Indicator: 5-digit configurable to %mA or other physical units
Signal noise is suppressed using Smart filtering.
Linearization or user-defined characteristic processing can be applied to the measured signal.
Use the machine's buttons for routine operations.
Utilize HART or FOXCOM communication protocols for communication
Supports Fieldbus FF communication protocol
Simulated output signals for loop testing
Continuous self-diagnosis
Configurable safety setpoints
Materials for various corrosive media are available for selection.
Casing protection IP66 (as per DIN 40050)
The product is explosion-proof and intrinsically safe, suitable for use in explosive areas.
Sensor and amplifier can be installed either as a single unit or as separate components.
Key Technical Parameters
Measuring Range: 300~3,000mm (larger ranges available upon request)
Accuracy: Level measurement ±0.5% FS, Interface measurement ±1% FS
Repeatability: ≤±0.25% FS
Deadband: ≤±0.2% FS
Power Supply: 12-30VDC
Output Signal: Analog: 4~20mA DC
Digital Quantity: According to HART or FOXCOM communication protocol, FF fieldbus communication protocol
LCD Display: Analog mA or Level, Interface, and Percentage Range
Load Resistance: 700Ω (when powered by 24VDC)
Density Range: 100 < ρ < 2000 kg/m³
Density Difference: 0.05 g/cm³
Working Pressure: 2.5~32.0 MPa
Medium Temperature: -196°C to +400°C
Ambient Temperature: -40°C to +70°C
Impact of working conditions:
Power Supply Impact: Output variation ≤ ±0.2% FS when voltage varies between the minimum and maximum specified values.
Temperature Impact: ≤0.1% / 10℃
Alarm Current: The transmitter outputs an alarm current when the liquid level is 10% below the lower limit of the transmitter's range or 10% above the upper limit of the transmitter's range, set at either 3.8mA or 22.8mA.
Protection Level: IP65 (NEMA 4X)
Intrinsically Safe Class: Type "ia" Exia II CT1~T4
Explosion-proof: ExdIICT1~T6
Electrical Interface: 2 x 1/2-14 NPT female threads
Cable Diameter: 6-12mm
Process Connection:
Saddle float type: Equipped with DIN or ANSI flange standards, flange size DN80 or 3" and above; for smaller flange sizes, please consult at the time of order.
Buoyant Floating Saddle: HG20592~20635-97; Flanges with DN20 and above, other flange standards (such as GB, JB/T, HGJ, ANSI, DIN, etc.) should be specified at the time of order.
Hot jacket: DN15 PN1.0 RF, other specifications to be specified upon order
Amplifier Detachable Installation Mounting Accessories: Installation Components
Cable Length: 3m / 10m / User-Specified Length
Material: Buoy: 304; 316
Clamping body: Carbon steel; 304; 316; Haste C alloy
Clamping Body Heat Sheath: 304
External Buoyancy Cylinder: Carbon Steel; 304; 316
Torsion Tube: 316L; InconelNel 600, 3J1, 3J53, Haste C alloy
Connector box: Aluminum alloy
Design Selection:
Registered Model | LC3010 Smart Buoy Level (High/Low Level) Transmitter |
Communication Methods | Default HART Communication Protocol |
Main Material | 304 |
Q235 steel | |
321 SCS321 1Cr18Ni9Ti 1.4873 | |
316Ti OCr18Ni12Mo2Ti 1.4571 | |
316 SVS316 OOCr17Ni12Mo2 1.4401 | |
316L SVS316L OOCr14Ni12Mo2 1.4435 | |
Special Material (to be specified) | |
Installation Method | Side-mounted floating buoy |
Side-bottom mounted external buoyant筒 | |
Top-side mounted external buoyant buoy | |
Floating Buoy Top and Bottom Mounting | |
Internal Buoyant筒顶mounted | |
Parameter under Test | Measure liquid level |
Setpoint measurement | |
Measure Density | |
Pressure Rating | 2.5MPa/Class 150LB ANSI |
4.0MPa/Class 300LB ANSI | |
6.3MPa/Class 600LB ANSI | |
16.0MPa/Class 900LB ANSI | |
32.0MPa/Class 1500LB ANSI | |
40.0MPa/Class 2500LB ANSI | |
Process Temperature | Room Temperature -40℃ to 150℃ |
High-Temperature Type - 150℃ to 400℃ | |
Low Temperature Type - -196℃ to 150℃ | |
Explosion-proof type | No explosion-proof requirements |
Explosion-proof ExdIICT1-T6 | |
intrinsic safety ExiaIICT1~T6 | |
Safety grid (refer to the user manual) | |
Additional Steam Jacket | Tubular body without jacket |
Steam jacket, Process connection | |
Steam jacket / Process connection / JB/T82.1-94 DN15 PN1.0 | |
Measurement Range (MM) | 0~1200mm |
Medium density kg/m³ | 998 |